EESchema-LIBRARY Version 2.3 29/04/2008-12:21:34 # Converted with eagle2kicad.ulp Version 0.9 # Device count = 333 # # Dev Name: ACF2101P # Package Name: DIL24-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ACF2101P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ACF2101 F0 "IC" -400 925 50 H V L B F1 "ACF2101P" -400 -900 50 H V L B F2 "burr-brown-DIL24-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 300 -800 P 2 1 0 0 300 -800 300 900 P 2 1 0 0 300 900 -400 900 P 2 1 0 0 -400 900 -400 -800 X CAPA 4 -600 -600 200 R 40 40 1 1 P X CAPB 9 -600 -700 200 R 40 40 1 1 P X COMA 3 -600 300 200 R 40 40 1 1 I X COMB 10 -600 200 200 R 40 40 1 1 I X GNDA 2 500 -600 200 L 40 40 1 1 W X GNDB 11 500 -700 200 L 40 40 1 1 W X HOLDA 20 -600 -100 200 R 40 40 1 1 I X HOLDB 17 -600 -200 200 R 40 40 1 1 I X INA 5 -600 800 200 R 40 40 1 1 I X INB 8 -600 700 200 R 40 40 1 1 I X OUTA 1 500 800 200 L 40 40 1 1 O X OUTB 12 500 700 200 L 40 40 1 1 O X RESA 21 -600 100 200 R 40 40 1 1 I X RESB 16 -600 0 200 R 40 40 1 1 I X SCOMA 23 500 300 200 L 40 40 1 1 O X SCOMB 14 500 200 200 L 40 40 1 1 O X SELA 22 -600 -300 200 R 40 40 1 1 I X SELB 15 -600 -400 200 R 40 40 1 1 I X SINA 6 -600 500 200 R 40 40 1 1 I X SINB 7 -600 400 200 R 40 40 1 1 I X SOUTA 24 500 500 200 L 40 40 1 1 O X SOUTB 13 500 400 200 L 40 40 1 1 O X V+ 19 500 -300 200 L 40 40 1 1 W X V- 18 500 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ACF2101U # Package Name: SO24L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ACF2101U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ACF2101 F0 "IC" -400 925 50 H V L B F1 "ACF2101U" -400 -900 50 H V L B F2 "burr-brown-SO24L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 300 -800 P 2 1 0 0 300 -800 300 900 P 2 1 0 0 300 900 -400 900 P 2 1 0 0 -400 900 -400 -800 X CAPA 22 -600 -600 200 R 40 40 1 1 P X CAPB 3 -600 -700 200 R 40 40 1 1 P X COMA 21 -600 300 200 R 40 40 1 1 I X COMB 4 -600 200 200 R 40 40 1 1 I X GNDA 20 500 -600 200 L 40 40 1 1 W X GNDB 5 500 -700 200 L 40 40 1 1 W X HOLDA 14 -600 -100 200 R 40 40 1 1 I X HOLDB 11 -600 -200 200 R 40 40 1 1 I X INA 23 -600 800 200 R 40 40 1 1 I X INB 2 -600 700 200 R 40 40 1 1 I X OUTA 19 500 800 200 L 40 40 1 1 O X OUTB 6 500 700 200 L 40 40 1 1 O X RESA 15 -600 100 200 R 40 40 1 1 I X RESB 10 -600 0 200 R 40 40 1 1 I X SCOMA 17 500 300 200 L 40 40 1 1 O X SCOMB 8 500 200 200 L 40 40 1 1 O X SELA 16 -600 -300 200 R 40 40 1 1 I X SELB 9 -600 -400 200 R 40 40 1 1 I X SINA 24 -600 500 200 R 40 40 1 1 I X SINB 1 -600 400 200 R 40 40 1 1 I X SOUTA 18 500 500 200 L 40 40 1 1 O X SOUTB 7 500 400 200 L 40 40 1 1 O X V+ 13 500 -300 200 L 40 40 1 1 W X V- 12 500 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADC7802PLC # Package Name: PLCC28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADC7802PLC IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADC7802 F0 "IC" -500 1350 50 H V L B F1 "ADC7802PLC" -500 -1600 50 H V L B F2 "burr-brown-PLCC28" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -1500 400 -1500 P 2 1 0 0 400 1300 -500 1300 P 2 1 0 0 -500 1300 -500 -1500 P 2 1 0 0 400 -1500 400 1300 X /BUSY 22 500 -700 100 L 40 40 1 1 O X /CAL 26 500 -1000 100 L 40 40 1 1 I X /CS 19 500 -100 100 L 40 40 1 1 I X /RD 18 500 -500 100 L 40 40 1 1 I X /WR 20 500 -400 100 L 40 40 1 1 I X A0 24 500 100 100 L 40 40 1 1 I X A1 25 500 0 100 L 40 40 1 1 I X AGND 27 -600 -400 100 R 40 40 1 1 P X AIN0 2 -600 1200 100 R 40 40 1 1 I X AIN1 3 -600 800 100 R 40 40 1 1 I X AIN2 4 -600 400 100 R 40 40 1 1 I X AIN3 5 -600 0 100 R 40 40 1 1 I X CLK 23 500 1200 100 L 40 40 1 1 I C X D0/D8 17 500 1000 100 L 40 40 1 1 T X D1/D9 16 500 900 100 L 40 40 1 1 T X D2/D10 15 500 800 100 L 40 40 1 1 T X D3/D11 14 500 700 100 L 40 40 1 1 T X D4 13 500 600 100 L 40 40 1 1 T X D5 12 500 500 100 L 40 40 1 1 T X D6 11 500 400 100 L 40 40 1 1 T X D7 10 500 300 100 L 40 40 1 1 T X DGND 8 500 -1400 100 L 40 40 1 1 P X HBE 21 500 -200 100 L 40 40 1 1 I X SFR 1 500 -900 100 L 40 40 1 1 P X VA 28 500 -1200 100 L 40 40 1 1 P X VD 9 500 -1300 100 L 40 40 1 1 P X VREF+ 6 -600 -1100 100 R 40 40 1 1 I X VREF- 7 -600 -1400 100 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADC7802PLC-S # Package Name: PLCC-S28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADC7802PLC-S IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADC7802 F0 "IC" -500 1350 50 H V L B F1 "ADC7802PLC-S" -500 -1600 50 H V L B F2 "burr-brown-PLCC-S28" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -1500 400 -1500 P 2 1 0 0 400 1300 -500 1300 P 2 1 0 0 -500 1300 -500 -1500 P 2 1 0 0 400 -1500 400 1300 X /BUSY 22 500 -700 100 L 40 40 1 1 O X /CAL 26 500 -1000 100 L 40 40 1 1 I X /CS 19 500 -100 100 L 40 40 1 1 I X /RD 18 500 -500 100 L 40 40 1 1 I X /WR 20 500 -400 100 L 40 40 1 1 I X A0 24 500 100 100 L 40 40 1 1 I X A1 25 500 0 100 L 40 40 1 1 I X AGND 27 -600 -400 100 R 40 40 1 1 P X AIN0 2 -600 1200 100 R 40 40 1 1 I X AIN1 3 -600 800 100 R 40 40 1 1 I X AIN2 4 -600 400 100 R 40 40 1 1 I X AIN3 5 -600 0 100 R 40 40 1 1 I X CLK 23 500 1200 100 L 40 40 1 1 I C X D0/D8 17 500 1000 100 L 40 40 1 1 T X D1/D9 16 500 900 100 L 40 40 1 1 T X D2/D10 15 500 800 100 L 40 40 1 1 T X D3/D11 14 500 700 100 L 40 40 1 1 T X D4 13 500 600 100 L 40 40 1 1 T X D5 12 500 500 100 L 40 40 1 1 T X D6 11 500 400 100 L 40 40 1 1 T X D7 10 500 300 100 L 40 40 1 1 T X DGND 8 500 -1400 100 L 40 40 1 1 P X HBE 21 500 -200 100 L 40 40 1 1 I X SFR 1 500 -900 100 L 40 40 1 1 P X VA 28 500 -1200 100 L 40 40 1 1 P X VD 9 500 -1300 100 L 40 40 1 1 P X VREF+ 6 -600 -1100 100 R 40 40 1 1 I X VREF- 7 -600 -1400 100 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS574JE # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS574JE IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS574 F0 "IC" -300 1125 50 H V L B F1 "ADS574JE" -300 -1200 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X 10VR 13 -500 300 200 R 40 40 1 1 I X 12/8\ 2 -500 900 200 R 40 40 1 1 I X 20VR 14 -500 200 200 R 40 40 1 1 I X ACOM 9 600 -900 200 L 40 40 1 1 W X AO 4 -500 1000 200 R 40 40 1 1 I X BO 12 -500 400 200 R 40 40 1 1 I X CE 6 -500 600 200 R 40 40 1 1 I X CS\ 3 -500 800 200 R 40 40 1 1 I X DB0 27 600 1000 200 L 40 40 1 1 O X DB1 26 600 900 200 L 40 40 1 1 O X DB2 25 600 800 200 L 40 40 1 1 O X DB3 24 600 700 200 L 40 40 1 1 O X DB4 23 600 600 200 L 40 40 1 1 O X DB5 22 600 500 200 L 40 40 1 1 O X DB6 21 600 400 200 L 40 40 1 1 O X DB7 20 600 300 200 L 40 40 1 1 O X DB8 19 600 200 200 L 40 40 1 1 O X DB9 18 600 100 200 L 40 40 1 1 O X DB10 17 600 0 200 L 40 40 1 1 O X DB11 16 600 -100 200 L 40 40 1 1 O X DCOM 15 600 -1000 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X R/C\ 5 -500 700 200 R 40 40 1 1 I X REFIN 10 -500 500 200 R 40 40 1 1 I X REFOUT 8 600 -300 200 L 40 40 1 1 O X STATUS 28 600 -400 200 L 40 40 1 1 O X VDD 1 600 -700 200 L 40 40 1 1 W X VEE 11 600 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS574P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS574P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS574 F0 "IC" -300 1125 50 H V L B F1 "ADS574P" -300 -1200 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X 10VR 13 -500 300 200 R 40 40 1 1 I X 12/8\ 2 -500 900 200 R 40 40 1 1 I X 20VR 14 -500 200 200 R 40 40 1 1 I X ACOM 9 600 -900 200 L 40 40 1 1 W X AO 4 -500 1000 200 R 40 40 1 1 I X BO 12 -500 400 200 R 40 40 1 1 I X CE 6 -500 600 200 R 40 40 1 1 I X CS\ 3 -500 800 200 R 40 40 1 1 I X DB0 16 600 1000 200 L 40 40 1 1 O X DB1 17 600 900 200 L 40 40 1 1 O X DB2 18 600 800 200 L 40 40 1 1 O X DB3 19 600 700 200 L 40 40 1 1 O X DB4 20 600 600 200 L 40 40 1 1 O X DB5 21 600 500 200 L 40 40 1 1 O X DB6 22 600 400 200 L 40 40 1 1 O X DB7 23 600 300 200 L 40 40 1 1 O X DB8 24 600 200 200 L 40 40 1 1 O X DB9 25 600 100 200 L 40 40 1 1 O X DB10 26 600 0 200 L 40 40 1 1 O X DB11 27 600 -100 200 L 40 40 1 1 O X DCOM 15 600 -1000 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X R/C\ 5 -500 700 200 R 40 40 1 1 I X REFIN 10 -500 500 200 R 40 40 1 1 I X REFOUT 8 600 -300 200 L 40 40 1 1 O X STATUS 28 600 -400 200 L 40 40 1 1 O X VDD 1 600 -700 200 L 40 40 1 1 W X VEE 11 600 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS574U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS574U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS574 F0 "IC" -300 1125 50 H V L B F1 "ADS574U" -300 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X 10VR 13 -500 300 200 R 40 40 1 1 I X 12/8\ 2 -500 900 200 R 40 40 1 1 I X 20VR 14 -500 200 200 R 40 40 1 1 I X ACOM 9 600 -900 200 L 40 40 1 1 W X AO 4 -500 1000 200 R 40 40 1 1 I X BO 12 -500 400 200 R 40 40 1 1 I X CE 6 -500 600 200 R 40 40 1 1 I X CS\ 3 -500 800 200 R 40 40 1 1 I X DB0 16 600 1000 200 L 40 40 1 1 O X DB1 17 600 900 200 L 40 40 1 1 O X DB2 18 600 800 200 L 40 40 1 1 O X DB3 19 600 700 200 L 40 40 1 1 O X DB4 20 600 600 200 L 40 40 1 1 O X DB5 21 600 500 200 L 40 40 1 1 O X DB6 22 600 400 200 L 40 40 1 1 O X DB7 23 600 300 200 L 40 40 1 1 O X DB8 24 600 200 200 L 40 40 1 1 O X DB9 25 600 100 200 L 40 40 1 1 O X DB10 26 600 0 200 L 40 40 1 1 O X DB11 27 600 -100 200 L 40 40 1 1 O X DCOM 15 600 -1000 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X R/C\ 5 -500 700 200 R 40 40 1 1 I X REFIN 10 -500 500 200 R 40 40 1 1 I X REFOUT 8 600 -300 200 L 40 40 1 1 O X STATUS 28 600 -400 200 L 40 40 1 1 O X VDD 1 600 -700 200 L 40 40 1 1 W X VEE 11 600 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS774JE # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS774JE IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS574 F0 "IC" -300 1125 50 H V L B F1 "ADS774JE" -300 -1200 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X 10VR 13 -500 300 200 R 40 40 1 1 I X 12/8\ 2 -500 900 200 R 40 40 1 1 I X 20VR 14 -500 200 200 R 40 40 1 1 I X ACOM 9 600 -900 200 L 40 40 1 1 W X AO 4 -500 1000 200 R 40 40 1 1 I X BO 12 -500 400 200 R 40 40 1 1 I X CE 6 -500 600 200 R 40 40 1 1 I X CS\ 3 -500 800 200 R 40 40 1 1 I X DB0 16 600 1000 200 L 40 40 1 1 O X DB1 17 600 900 200 L 40 40 1 1 O X DB2 18 600 800 200 L 40 40 1 1 O X DB3 19 600 700 200 L 40 40 1 1 O X DB4 20 600 600 200 L 40 40 1 1 O X DB5 21 600 500 200 L 40 40 1 1 O X DB6 22 600 400 200 L 40 40 1 1 O X DB7 23 600 300 200 L 40 40 1 1 O X DB8 24 600 200 200 L 40 40 1 1 O X DB9 25 600 100 200 L 40 40 1 1 O X DB10 26 600 0 200 L 40 40 1 1 O X DB11 27 600 -100 200 L 40 40 1 1 O X DCOM 15 600 -1000 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X R/C\ 5 -500 700 200 R 40 40 1 1 I X REFIN 10 -500 500 200 R 40 40 1 1 I X REFOUT 8 600 -300 200 L 40 40 1 1 O X STATUS 28 600 -400 200 L 40 40 1 1 O X VDD 1 600 -700 200 L 40 40 1 1 W X VEE 11 600 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS774P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS774P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS574 F0 "IC" -300 1125 50 H V L B F1 "ADS774P" -300 -1200 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X 10VR 13 -500 300 200 R 40 40 1 1 I X 12/8\ 2 -500 900 200 R 40 40 1 1 I X 20VR 14 -500 200 200 R 40 40 1 1 I X ACOM 9 600 -900 200 L 40 40 1 1 W X AO 4 -500 1000 200 R 40 40 1 1 I X BO 12 -500 400 200 R 40 40 1 1 I X CE 6 -500 600 200 R 40 40 1 1 I X CS\ 3 -500 800 200 R 40 40 1 1 I X DB0 16 600 1000 200 L 40 40 1 1 O X DB1 17 600 900 200 L 40 40 1 1 O X DB2 18 600 800 200 L 40 40 1 1 O X DB3 19 600 700 200 L 40 40 1 1 O X DB4 20 600 600 200 L 40 40 1 1 O X DB5 21 600 500 200 L 40 40 1 1 O X DB6 22 600 400 200 L 40 40 1 1 O X DB7 23 600 300 200 L 40 40 1 1 O X DB8 24 600 200 200 L 40 40 1 1 O X DB9 25 600 100 200 L 40 40 1 1 O X DB10 26 600 0 200 L 40 40 1 1 O X DB11 27 600 -100 200 L 40 40 1 1 O X DCOM 15 600 -1000 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X R/C\ 5 -500 700 200 R 40 40 1 1 I X REFIN 10 -500 500 200 R 40 40 1 1 I X REFOUT 8 600 -300 200 L 40 40 1 1 O X STATUS 28 600 -400 200 L 40 40 1 1 O X VDD 1 600 -700 200 L 40 40 1 1 W X VEE 11 600 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS774U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS774U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS574 F0 "IC" -300 1125 50 H V L B F1 "ADS774U" -300 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X 10VR 13 -500 300 200 R 40 40 1 1 I X 12/8\ 2 -500 900 200 R 40 40 1 1 I X 20VR 14 -500 200 200 R 40 40 1 1 I X ACOM 9 600 -900 200 L 40 40 1 1 W X AO 4 -500 1000 200 R 40 40 1 1 I X BO 12 -500 400 200 R 40 40 1 1 I X CE 6 -500 600 200 R 40 40 1 1 I X CS\ 3 -500 800 200 R 40 40 1 1 I X DB0 16 600 1000 200 L 40 40 1 1 O X DB1 17 600 900 200 L 40 40 1 1 O X DB2 18 600 800 200 L 40 40 1 1 O X DB3 19 600 700 200 L 40 40 1 1 O X DB4 20 600 600 200 L 40 40 1 1 O X DB5 21 600 500 200 L 40 40 1 1 O X DB6 22 600 400 200 L 40 40 1 1 O X DB7 23 600 300 200 L 40 40 1 1 O X DB8 24 600 200 200 L 40 40 1 1 O X DB9 25 600 100 200 L 40 40 1 1 O X DB10 26 600 0 200 L 40 40 1 1 O X DB11 27 600 -100 200 L 40 40 1 1 O X DCOM 15 600 -1000 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X R/C\ 5 -500 700 200 R 40 40 1 1 I X REFIN 10 -500 500 200 R 40 40 1 1 I X REFOUT 8 600 -300 200 L 40 40 1 1 O X STATUS 28 600 -400 200 L 40 40 1 1 O X VDD 1 600 -700 200 L 40 40 1 1 W X VEE 11 600 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS800E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS800E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS800 F0 "IC" -300 1125 50 H V L B F1 "ADS800E" -300 -1300 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1200 -300 -1200 P 2 1 0 0 -300 -1200 -300 1100 P 2 1 0 0 -300 1100 300 1100 P 2 1 0 0 300 1100 300 -1200 X +VS 15 500 -300 200 L 40 40 1 1 W X +VS@1 17 500 -400 200 L 40 40 1 1 W X +VS@2 20 500 -500 200 L 40 40 1 1 W X +VS@3 24 500 -600 200 L 40 40 1 1 W X B1 2 500 1000 200 L 40 40 1 1 O X B2 3 500 900 200 L 40 40 1 1 O X B3 4 500 800 200 L 40 40 1 1 O X B4 5 500 700 200 L 40 40 1 1 O X B5 6 500 600 200 L 40 40 1 1 O X B6 7 500 500 200 L 40 40 1 1 O X B7 8 500 400 200 L 40 40 1 1 O X B8 9 500 300 200 L 40 40 1 1 O X B9 10 500 200 200 L 40 40 1 1 O X B10 11 500 100 200 L 40 40 1 1 O X B11 12 500 0 200 L 40 40 1 1 O X B12 13 500 -100 200 L 40 40 1 1 O X CLK 16 -500 700 200 R 40 40 1 1 I X CM 22 -500 200 200 R 40 40 1 1 P X GND 1 500 -800 200 L 40 40 1 1 W X GND@1 14 500 -900 200 L 40 40 1 1 W X GND@2 25 500 -1000 200 L 40 40 1 1 W X GND@3 28 500 -1100 200 L 40 40 1 1 W X IN 26 -500 1000 200 R 40 40 1 1 I X IN\ 27 -500 900 200 R 40 40 1 1 I X MSBI 19 -500 500 200 R 40 40 1 1 I X OE\ 18 -500 600 200 R 40 40 1 1 I X REFB 21 -500 100 200 R 40 40 1 1 P X REFT 23 -500 300 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: ADS800U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS800U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS800 F0 "IC" -300 1125 50 H V L B F1 "ADS800U" -300 -1300 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1200 -300 -1200 P 2 1 0 0 -300 -1200 -300 1100 P 2 1 0 0 -300 1100 300 1100 P 2 1 0 0 300 1100 300 -1200 X +VS 15 500 -300 200 L 40 40 1 1 W X +VS@1 17 500 -400 200 L 40 40 1 1 W X +VS@2 20 500 -500 200 L 40 40 1 1 W X +VS@3 24 500 -600 200 L 40 40 1 1 W X B1 2 500 1000 200 L 40 40 1 1 O X B2 3 500 900 200 L 40 40 1 1 O X B3 4 500 800 200 L 40 40 1 1 O X B4 5 500 700 200 L 40 40 1 1 O X B5 6 500 600 200 L 40 40 1 1 O X B6 7 500 500 200 L 40 40 1 1 O X B7 8 500 400 200 L 40 40 1 1 O X B8 9 500 300 200 L 40 40 1 1 O X B9 10 500 200 200 L 40 40 1 1 O X B10 11 500 100 200 L 40 40 1 1 O X B11 12 500 0 200 L 40 40 1 1 O X B12 13 500 -100 200 L 40 40 1 1 O X CLK 16 -500 700 200 R 40 40 1 1 I X CM 22 -500 200 200 R 40 40 1 1 P X GND 1 500 -800 200 L 40 40 1 1 W X GND@1 14 500 -900 200 L 40 40 1 1 W X GND@2 25 500 -1000 200 L 40 40 1 1 W X GND@3 28 500 -1100 200 L 40 40 1 1 W X IN 26 -500 1000 200 R 40 40 1 1 I X IN\ 27 -500 900 200 R 40 40 1 1 I X MSBI 19 -500 500 200 R 40 40 1 1 I X OE\ 18 -500 600 200 R 40 40 1 1 I X REFB 21 -500 100 200 R 40 40 1 1 P X REFT 23 -500 300 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: ADS801E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS801E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS801 F0 "IC" -400 1025 50 H V L B F1 "ADS801E" -400 -1400 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1300 P 2 1 0 0 300 -1300 -400 -1300 P 2 1 0 0 -400 -1300 -400 1000 X +VS 15 500 -400 200 L 40 40 1 1 W X +VS@1 17 500 -500 200 L 40 40 1 1 W X +VS@2 20 500 -600 200 L 40 40 1 1 W X +VS@3 24 500 -700 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X B11 12 500 -100 200 L 40 40 1 1 O X B12 13 500 -200 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -900 200 L 40 40 1 1 W X GND@1 14 500 -1000 200 L 40 40 1 1 W X GND@2 25 500 -1100 200 L 40 40 1 1 W X GND@3 28 500 -1200 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 -200 200 R 40 40 1 1 I X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS801U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS801U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS801 F0 "IC" -400 1025 50 H V L B F1 "ADS801U" -400 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1300 P 2 1 0 0 300 -1300 -400 -1300 P 2 1 0 0 -400 -1300 -400 1000 X +VS 15 500 -400 200 L 40 40 1 1 W X +VS@1 17 500 -500 200 L 40 40 1 1 W X +VS@2 20 500 -600 200 L 40 40 1 1 W X +VS@3 24 500 -700 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X B11 12 500 -100 200 L 40 40 1 1 O X B12 13 500 -200 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -900 200 L 40 40 1 1 W X GND@1 14 500 -1000 200 L 40 40 1 1 W X GND@2 25 500 -1100 200 L 40 40 1 1 W X GND@3 28 500 -1200 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 -200 200 R 40 40 1 1 I X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS802E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS802E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS801 F0 "IC" -400 1025 50 H V L B F1 "ADS802E" -400 -1400 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1300 P 2 1 0 0 300 -1300 -400 -1300 P 2 1 0 0 -400 -1300 -400 1000 X +VS 15 500 -400 200 L 40 40 1 1 W X +VS@1 17 500 -500 200 L 40 40 1 1 W X +VS@2 20 500 -600 200 L 40 40 1 1 W X +VS@3 24 500 -700 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X B11 12 500 -100 200 L 40 40 1 1 O X B12 13 500 -200 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -900 200 L 40 40 1 1 W X GND@1 14 500 -1000 200 L 40 40 1 1 W X GND@2 25 500 -1100 200 L 40 40 1 1 W X GND@3 28 500 -1200 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 -200 200 R 40 40 1 1 I X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS802U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS802U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS801 F0 "IC" -400 1025 50 H V L B F1 "ADS802U" -400 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1300 P 2 1 0 0 300 -1300 -400 -1300 P 2 1 0 0 -400 -1300 -400 1000 X +VS 15 500 -400 200 L 40 40 1 1 W X +VS@1 17 500 -500 200 L 40 40 1 1 W X +VS@2 20 500 -600 200 L 40 40 1 1 W X +VS@3 24 500 -700 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X B11 12 500 -100 200 L 40 40 1 1 O X B12 13 500 -200 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -900 200 L 40 40 1 1 W X GND@1 14 500 -1000 200 L 40 40 1 1 W X GND@2 25 500 -1100 200 L 40 40 1 1 W X GND@3 28 500 -1200 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 -200 200 R 40 40 1 1 I X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS820E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS820E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS820 F0 "IC" -400 1025 50 H V L B F1 "ADS820E" -400 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1000 X +VS 15 500 -200 200 L 40 40 1 1 W X +VS@1 17 500 -300 200 L 40 40 1 1 W X +VS@2 20 500 -400 200 L 40 40 1 1 W X +VS@3 24 500 -500 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 25 500 -900 200 L 40 40 1 1 W X GND@3 28 500 -1000 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 400 200 R 40 40 1 1 I X NC 12 -600 -200 200 R 40 40 1 1 U X NC@1 13 -600 -300 200 R 40 40 1 1 U X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS820U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS820U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS820 F0 "IC" -400 1025 50 H V L B F1 "ADS820U" -400 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1000 X +VS 15 500 -200 200 L 40 40 1 1 W X +VS@1 17 500 -300 200 L 40 40 1 1 W X +VS@2 20 500 -400 200 L 40 40 1 1 W X +VS@3 24 500 -500 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 25 500 -900 200 L 40 40 1 1 W X GND@3 28 500 -1000 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 400 200 R 40 40 1 1 I X NC 12 -600 -200 200 R 40 40 1 1 U X NC@1 13 -600 -300 200 R 40 40 1 1 U X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS821E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS821E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS820 F0 "IC" -400 1025 50 H V L B F1 "ADS821E" -400 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1000 X +VS 15 500 -200 200 L 40 40 1 1 W X +VS@1 17 500 -300 200 L 40 40 1 1 W X +VS@2 20 500 -400 200 L 40 40 1 1 W X +VS@3 24 500 -500 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 28 500 -900 200 L 40 40 1 1 W X GND@3 25 500 -1000 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 400 200 R 40 40 1 1 I X NC 12 -600 -200 200 R 40 40 1 1 U X NC@1 13 -600 -300 200 R 40 40 1 1 U X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS821U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS821U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS820 F0 "IC" -400 1025 50 H V L B F1 "ADS821U" -400 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1000 X +VS 15 500 -200 200 L 40 40 1 1 W X +VS@1 17 500 -300 200 L 40 40 1 1 W X +VS@2 20 500 -400 200 L 40 40 1 1 W X +VS@3 24 500 -500 200 L 40 40 1 1 W X B1 2 500 900 200 L 40 40 1 1 O X B2 3 500 800 200 L 40 40 1 1 O X B3 4 500 700 200 L 40 40 1 1 O X B4 5 500 600 200 L 40 40 1 1 O X B5 6 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 8 500 300 200 L 40 40 1 1 O X B8 9 500 200 200 L 40 40 1 1 O X B9 10 500 100 200 L 40 40 1 1 O X B10 11 500 0 200 L 40 40 1 1 O X CLK 16 -600 600 200 R 40 40 1 1 I X CM 22 -600 100 200 R 40 40 1 1 I X GND 1 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 25 500 -900 200 L 40 40 1 1 W X GND@3 28 500 -1000 200 L 40 40 1 1 W X IN 26 -600 900 200 R 40 40 1 1 I X IN\ 27 -600 800 200 R 40 40 1 1 I X MSBI 19 -600 400 200 R 40 40 1 1 I X NC 12 -600 -200 200 R 40 40 1 1 U X NC@1 13 -600 -300 200 R 40 40 1 1 U X OE\ 18 -600 500 200 R 40 40 1 1 I X REFB 21 -600 0 200 R 40 40 1 1 I X REFT 23 -600 200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS823E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS823E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS823 F0 "IC" -400 925 50 H V L B F1 "ADS823E" -400 -1100 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 900 300 900 P 2 1 0 0 300 900 300 -1000 P 2 1 0 0 300 -1000 -400 -1000 P 2 1 0 0 -400 -1000 -400 900 X +VS 15 500 -300 200 L 40 40 1 1 W X +VS@1 27 500 -400 200 L 40 40 1 1 W X B1 2 500 800 200 L 40 40 1 1 O X B2 3 500 700 200 L 40 40 1 1 O X B3 4 500 600 200 L 40 40 1 1 O X B4 5 500 500 200 L 40 40 1 1 O X B5 6 500 400 200 L 40 40 1 1 O X B6 7 500 300 200 L 40 40 1 1 O X B7 8 500 200 200 L 40 40 1 1 O X B8 9 500 100 200 L 40 40 1 1 O X B9 10 500 0 200 L 40 40 1 1 O X B10 11 500 -100 200 L 40 40 1 1 O X BYB 20 -600 -600 200 R 40 40 1 1 P X BYT 21 -600 -500 200 R 40 40 1 1 P X CLK 14 -600 500 200 R 40 40 1 1 I X CM 23 -600 -200 200 R 40 40 1 1 I X GND 1 500 -600 200 L 40 40 1 1 W X GND@1 16 500 -700 200 L 40 40 1 1 W X GND@2 26 500 -800 200 L 40 40 1 1 W X IN 25 -600 800 200 R 40 40 1 1 I X INT/EXT 18 -600 300 200 R 40 40 1 1 I X IN\ 24 -600 700 200 R 40 40 1 1 I X OE\ 12 -600 400 200 R 40 40 1 1 I X PD 13 -600 200 200 R 40 40 1 1 I X REFB 19 -600 -300 200 R 40 40 1 1 I X REFT 22 -600 -100 200 R 40 40 1 1 I X RSEL 17 -600 0 200 R 40 40 1 1 I X VDRV 28 -600 100 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS824E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS824E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS823 F0 "IC" -400 925 50 H V L B F1 "ADS824E" -400 -1100 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 900 300 900 P 2 1 0 0 300 900 300 -1000 P 2 1 0 0 300 -1000 -400 -1000 P 2 1 0 0 -400 -1000 -400 900 X +VS 15 500 -300 200 L 40 40 1 1 W X +VS@1 27 500 -400 200 L 40 40 1 1 W X B1 2 500 800 200 L 40 40 1 1 O X B2 3 500 700 200 L 40 40 1 1 O X B3 4 500 600 200 L 40 40 1 1 O X B4 5 500 500 200 L 40 40 1 1 O X B5 6 500 400 200 L 40 40 1 1 O X B6 7 500 300 200 L 40 40 1 1 O X B7 8 500 200 200 L 40 40 1 1 O X B8 9 500 100 200 L 40 40 1 1 O X B9 10 500 0 200 L 40 40 1 1 O X B10 11 500 -100 200 L 40 40 1 1 O X BYB 20 -600 -600 200 R 40 40 1 1 P X BYT 21 -600 -500 200 R 40 40 1 1 P X CLK 14 -600 500 200 R 40 40 1 1 I X CM 23 -600 -200 200 R 40 40 1 1 I X GND 1 500 -600 200 L 40 40 1 1 W X GND@1 16 500 -700 200 L 40 40 1 1 W X GND@2 26 500 -800 200 L 40 40 1 1 W X IN 25 -600 800 200 R 40 40 1 1 I X INT/EXT 18 -600 300 200 R 40 40 1 1 I X IN\ 24 -600 700 200 R 40 40 1 1 I X OE\ 12 -600 400 200 R 40 40 1 1 I X PD 13 -600 200 200 R 40 40 1 1 I X REFB 19 -600 -300 200 R 40 40 1 1 I X REFT 22 -600 -100 200 R 40 40 1 1 I X RSEL 17 -600 0 200 R 40 40 1 1 I X VDRV 28 -600 100 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS900E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS900E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS900 F0 "IC" -400 1425 50 H V L B F1 "ADS900E" -400 -1400 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1400 300 1400 P 2 1 0 0 300 1400 300 -1300 P 2 1 0 0 300 -1300 -400 -1300 P 2 1 0 0 -400 -1300 -400 1400 X +VS 1 500 -400 200 L 40 40 1 1 W X +VS@1 18 500 -500 200 L 40 40 1 1 W X +VS@2 28 500 -600 200 L 40 40 1 1 W X 1VREF 23 500 -200 200 L 40 40 1 1 O X B1 12 500 1300 200 L 40 40 1 1 O X B2 11 500 1200 200 L 40 40 1 1 O X B3 10 500 1100 200 L 40 40 1 1 O X B4 9 500 1000 200 L 40 40 1 1 O X B5 8 500 900 200 L 40 40 1 1 O X B6 7 500 800 200 L 40 40 1 1 O X B7 6 500 700 200 L 40 40 1 1 O X B8 5 500 600 200 L 40 40 1 1 O X B9 4 500 500 200 L 40 40 1 1 O X B10 3 500 400 200 L 40 40 1 1 O X CLK 15 -600 1000 200 R 40 40 1 1 I X CM 26 500 100 200 L 40 40 1 1 O X GND 13 500 -900 200 L 40 40 1 1 W X GND@1 14 500 -1000 200 L 40 40 1 1 W X GND@2 19 500 -1100 200 L 40 40 1 1 W X GND@3 20 500 -1200 200 L 40 40 1 1 W X IN 27 -600 1300 200 R 40 40 1 1 I X IN\ 24 -600 1200 200 R 40 40 1 1 I X LNBY 25 500 0 200 L 40 40 1 1 O X LPBY 21 500 200 200 L 40 40 1 1 O X LVDD 2 500 -700 200 L 40 40 1 1 W X NC 22 -600 600 200 R 40 40 1 1 U X OE\ 16 -600 900 200 R 40 40 1 1 I X PWRD 17 -600 800 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS901E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS901E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS901 F0 "IC" -400 1225 50 H V L B F1 "ADS901E" -400 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1200 300 1200 P 2 1 0 0 300 1200 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1200 X +VS 1 500 -200 200 L 40 40 1 1 W X +VS@1 18 500 -300 200 L 40 40 1 1 W X +VS@2 28 500 -400 200 L 40 40 1 1 W X B1 12 500 1100 200 L 40 40 1 1 O X B2 11 500 1000 200 L 40 40 1 1 O X B3 10 500 900 200 L 40 40 1 1 O X B4 9 500 800 200 L 40 40 1 1 O X B5 8 500 700 200 L 40 40 1 1 O X B6 7 500 600 200 L 40 40 1 1 O X B7 6 500 500 200 L 40 40 1 1 O X B8 5 500 400 200 L 40 40 1 1 O X B9 4 500 300 200 L 40 40 1 1 O X B10 3 500 200 200 L 40 40 1 1 O X CLK 15 -600 600 200 R 40 40 1 1 I X CM 26 500 0 200 L 40 40 1 1 O X GND 13 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 19 500 -900 200 L 40 40 1 1 W X GND@3 20 500 -1000 200 L 40 40 1 1 W X IN 27 -600 1100 200 R 40 40 1 1 I X LNBY 25 -600 -100 200 R 40 40 1 1 P X LPBY 21 -600 0 200 R 40 40 1 1 P X LVDD 2 500 -500 200 L 40 40 1 1 W X NC 23 -600 200 200 R 40 40 1 1 U X OE\ 16 -600 500 200 R 40 40 1 1 I X PWRD 17 -600 400 200 R 40 40 1 1 I X REFB 24 -600 800 200 R 40 40 1 1 I X REFT 22 -600 900 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS902E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS902E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS902 F0 "IC" -400 1025 50 H V L B F1 "ADS902E" -400 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1000 300 1000 P 2 1 0 0 300 1000 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1000 X +VS 1 500 -200 200 L 40 40 1 1 W X +VS@1 18 500 -300 200 L 40 40 1 1 W X +VS@2 28 500 -400 200 L 40 40 1 1 W X B1 12 500 900 200 L 40 40 1 1 O X B2 11 500 800 200 L 40 40 1 1 O X B3 10 500 700 200 L 40 40 1 1 O X B4 9 500 600 200 L 40 40 1 1 O X B5 8 500 500 200 L 40 40 1 1 O X B6 7 500 400 200 L 40 40 1 1 O X B7 6 500 300 200 L 40 40 1 1 O X B8 5 500 200 200 L 40 40 1 1 O X B9 4 500 100 200 L 40 40 1 1 O X B10 3 500 0 200 L 40 40 1 1 O X CLK 15 -600 700 200 R 40 40 1 1 I X CM 26 -600 -300 200 R 40 40 1 1 B X GND 13 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 19 500 -900 200 L 40 40 1 1 W X GND@3 20 500 -1000 200 L 40 40 1 1 W X IN 27 -600 900 200 R 40 40 1 1 I X LNBY 25 -600 0 200 R 40 40 1 1 P X LPBY 21 -600 100 200 R 40 40 1 1 P X LVDD 2 500 -500 200 L 40 40 1 1 W X NC 23 -600 300 200 R 40 40 1 1 U X OE\ 16 -600 600 200 R 40 40 1 1 I X PWRD 17 -600 500 200 R 40 40 1 1 I X REFB 24 -600 -400 200 R 40 40 1 1 I X REFT 22 -600 -200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS930E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS930E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS930 F0 "IC" -400 1225 50 H V L B F1 "ADS930E" -400 -1300 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1200 300 1200 P 2 1 0 0 300 1200 300 -1200 P 2 1 0 0 300 -1200 -400 -1200 P 2 1 0 0 -400 -1200 -400 1200 X +IN 27 -600 1100 200 R 40 40 1 1 I X +VS 1 500 -300 200 L 40 40 1 1 W X +VS@1 18 500 -400 200 L 40 40 1 1 W X +VS@2 28 500 -500 200 L 40 40 1 1 W X 1VREF 23 500 -100 200 L 40 40 1 1 O X B1 12 500 1100 200 L 40 40 1 1 O X B2 11 500 1000 200 L 40 40 1 1 O X B3 10 500 900 200 L 40 40 1 1 O X B4 9 500 800 200 L 40 40 1 1 O X B5 8 500 700 200 L 40 40 1 1 O X B6 7 500 600 200 L 40 40 1 1 O X B7 6 500 500 200 L 40 40 1 1 O X B8 5 500 400 200 L 40 40 1 1 O X CLK 15 -600 800 200 R 40 40 1 1 I X CM 26 500 100 200 L 40 40 1 1 O X GND 13 500 -800 200 L 40 40 1 1 W X GND@1 14 500 -900 200 L 40 40 1 1 W X GND@2 19 500 -1000 200 L 40 40 1 1 W X GND@3 20 500 -1100 200 L 40 40 1 1 W X IN\ 24 -600 1000 200 R 40 40 1 1 I X LNBY 25 500 0 200 L 40 40 1 1 O X LPBY 21 500 200 200 L 40 40 1 1 O X LVDD 2 500 -600 200 L 40 40 1 1 W X NC 3 -600 400 200 R 40 40 1 1 U X NC@1 4 -600 300 200 R 40 40 1 1 U X NC@2 22 -600 200 200 R 40 40 1 1 U X OE\ 16 -600 700 200 R 40 40 1 1 I X PWRD 17 -600 600 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS931E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS931E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS931 F0 "IC" -400 1225 50 H V L B F1 "ADS931E" -400 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 1200 300 1200 P 2 1 0 0 300 1200 300 -1100 P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1200 X +VS 1 500 -200 200 L 40 40 1 1 W X +VS@1 18 500 -300 200 L 40 40 1 1 W X +VS@2 28 500 -400 200 L 40 40 1 1 W X B1 12 500 1100 200 L 40 40 1 1 O X B2 11 500 1000 200 L 40 40 1 1 O X B3 10 500 900 200 L 40 40 1 1 O X B4 9 500 800 200 L 40 40 1 1 O X B5 8 500 700 200 L 40 40 1 1 O X B6 7 500 600 200 L 40 40 1 1 O X B7 6 500 500 200 L 40 40 1 1 O X B8 5 500 400 200 L 40 40 1 1 O X CLK 15 -600 900 200 R 40 40 1 1 I X CM 26 500 100 200 L 40 40 1 1 O X GND 13 500 -700 200 L 40 40 1 1 W X GND@1 14 500 -800 200 L 40 40 1 1 W X GND@2 19 500 -900 200 L 40 40 1 1 W X GND@3 20 500 -1000 200 L 40 40 1 1 W X IN 27 -600 1100 200 R 40 40 1 1 I X LNBY 25 -600 0 200 R 40 40 1 1 P X LPBY 21 -600 100 200 R 40 40 1 1 P X LVDD 2 500 -500 200 L 40 40 1 1 W X NC 3 -600 500 200 R 40 40 1 1 U X NC@1 4 -600 400 200 R 40 40 1 1 U X NC@2 23 -600 300 200 R 40 40 1 1 U X OE\ 16 -600 800 200 R 40 40 1 1 I X PWRD 17 -600 700 200 R 40 40 1 1 I X REFB 24 500 0 200 L 40 40 1 1 O X REFT 22 500 200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1210P # Package Name: DIL18 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1210P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1212 F0 "IC" -400 625 50 H V L B F1 "ADS1210P" -400 -800 50 H V L B F2 "burr-brown-DIL18" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 400 -700 P 2 1 0 0 400 -700 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X AGND 3 600 -500 200 L 40 40 1 1 W X AINN 2 -600 400 200 R 40 40 1 1 I X AINP 1 -600 500 200 R 40 40 1 1 I X AVDD 16 600 -200 200 L 40 40 1 1 W X CS\ 5 -600 -200 200 R 40 40 1 1 I X DGND 9 600 -600 200 L 40 40 1 1 W X DRDY\ 14 600 0 200 L 40 40 1 1 O X DSYNC\ 6 -600 0 200 R 40 40 1 1 I X DVDD 10 600 -300 200 L 40 40 1 1 W X MODE 15 -600 -100 200 R 40 40 1 1 I X REFIN 18 -600 200 200 R 40 40 1 1 I X REFOUT 17 600 200 200 L 40 40 1 1 O X SCLK 11 -600 -400 200 R 40 40 1 1 B X SDIO 12 -600 -500 200 R 40 40 1 1 B X SDOUT 13 600 500 200 L 40 40 1 1 O X VBIAS 4 600 300 200 L 40 40 1 1 O X XIN 7 -600 100 200 R 40 40 1 1 I X XOUT 8 600 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1210U # Package Name: SO18L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1210U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1212 F0 "IC" -400 625 50 H V L B F1 "ADS1210U" -400 -800 50 H V L B F2 "burr-brown-SO18L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 400 -700 P 2 1 0 0 400 -700 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X AGND 3 600 -500 200 L 40 40 1 1 W X AINN 2 -600 400 200 R 40 40 1 1 I X AINP 1 -600 500 200 R 40 40 1 1 I X AVDD 16 600 -200 200 L 40 40 1 1 W X CS\ 5 -600 -200 200 R 40 40 1 1 I X DGND 9 600 -600 200 L 40 40 1 1 W X DRDY\ 14 600 0 200 L 40 40 1 1 O X DSYNC\ 6 -600 0 200 R 40 40 1 1 I X DVDD 10 600 -300 200 L 40 40 1 1 W X MODE 15 -600 -100 200 R 40 40 1 1 I X REFIN 18 -600 200 200 R 40 40 1 1 I X REFOUT 17 600 200 200 L 40 40 1 1 O X SCLK 11 -600 -400 200 R 40 40 1 1 B X SDIO 12 -600 -500 200 R 40 40 1 1 B X SDOUT 13 600 500 200 L 40 40 1 1 O X VBIAS 4 600 300 200 L 40 40 1 1 O X XIN 7 -600 100 200 R 40 40 1 1 I X XOUT 8 600 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1211E # Package Name: SSOP28DL # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1211E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1211 F0 "IC" -400 925 50 H V L B F1 "ADS1211E" -400 -1100 50 H V L B F2 "burr-brown-SSOP28DL" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 400 -1000 P 2 1 0 0 400 -1000 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X AGND 6 600 -800 200 L 40 40 1 1 W X AIN1N 5 -600 700 200 R 40 40 1 1 I X AIN1P 4 -600 800 200 R 40 40 1 1 I X AIN2N 3 -600 500 200 R 40 40 1 1 I X AIN2P 2 -600 600 200 R 40 40 1 1 I X AIN3N 1 -600 300 200 R 40 40 1 1 I X AIN3P 28 -600 400 200 R 40 40 1 1 I X AIN4N 27 -600 100 200 R 40 40 1 1 I X AIN4P 26 -600 200 200 R 40 40 1 1 I X AVDD 23 600 -500 200 L 40 40 1 1 W X CS\ 10 -600 -500 200 R 40 40 1 1 I X DGND 14 600 -900 200 L 40 40 1 1 W X DRDY\ 19 600 -300 200 L 40 40 1 1 O X DSYNC\ 11 -600 -300 200 R 40 40 1 1 I X DVDD 15 600 -600 200 L 40 40 1 1 W X MODE 22 -600 -400 200 R 40 40 1 1 I X REFIN 25 -600 -100 200 R 40 40 1 1 I X REFOUT 24 600 -100 200 L 40 40 1 1 O X SCLK 16 -600 -700 200 R 40 40 1 1 B X SDIO 17 -600 -800 200 R 40 40 1 1 B X SDOUT 18 600 800 200 L 40 40 1 1 O X VBIAS 7 600 0 200 L 40 40 1 1 O X XIN 12 -600 -200 200 R 40 40 1 1 I X XOUT 13 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1211P # Package Name: DIL24-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1211P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1211 F0 "IC" -400 925 50 H V L B F1 "ADS1211P" -400 -1100 50 H V L B F2 "burr-brown-DIL24-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 400 -1000 P 2 1 0 0 400 -1000 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X AGND 6 600 -800 200 L 40 40 1 1 W X AIN1N 5 -600 700 200 R 40 40 1 1 I X AIN1P 4 -600 800 200 R 40 40 1 1 I X AIN2N 3 -600 500 200 R 40 40 1 1 I X AIN2P 2 -600 600 200 R 40 40 1 1 I X AIN3N 1 -600 300 200 R 40 40 1 1 I X AIN3P 24 -600 400 200 R 40 40 1 1 I X AIN4N 23 -600 100 200 R 40 40 1 1 I X AIN4P 22 -600 200 200 R 40 40 1 1 I X AVDD 19 600 -500 200 L 40 40 1 1 W X CS\ 8 -600 -500 200 R 40 40 1 1 I X DGND 12 600 -900 200 L 40 40 1 1 W X DRDY\ 17 600 -300 200 L 40 40 1 1 O X DSYNC\ 9 -600 -300 200 R 40 40 1 1 I X DVDD 13 600 -600 200 L 40 40 1 1 W X MODE 18 -600 -400 200 R 40 40 1 1 I X REFIN 21 -600 -100 200 R 40 40 1 1 I X REFOUT 20 600 -100 200 L 40 40 1 1 O X SCLK 14 -600 -700 200 R 40 40 1 1 B X SDIO 15 -600 -800 200 R 40 40 1 1 B X SDOUT 16 600 800 200 L 40 40 1 1 O X VBIAS 7 600 0 200 L 40 40 1 1 O X XIN 10 -600 -200 200 R 40 40 1 1 I X XOUT 11 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1211U # Package Name: SO24L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1211U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1211 F0 "IC" -400 925 50 H V L B F1 "ADS1211U" -400 -1100 50 H V L B F2 "burr-brown-SO24L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 400 -1000 P 2 1 0 0 400 -1000 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X AGND 6 600 -800 200 L 40 40 1 1 W X AIN1N 5 -600 700 200 R 40 40 1 1 I X AIN1P 4 -600 800 200 R 40 40 1 1 I X AIN2N 3 -600 500 200 R 40 40 1 1 I X AIN2P 2 -600 600 200 R 40 40 1 1 I X AIN3N 1 -600 300 200 R 40 40 1 1 I X AIN3P 24 -600 400 200 R 40 40 1 1 I X AIN4N 23 -600 100 200 R 40 40 1 1 I X AIN4P 22 -600 200 200 R 40 40 1 1 I X AVDD 19 600 -500 200 L 40 40 1 1 W X CS\ 8 -600 -500 200 R 40 40 1 1 I X DGND 12 600 -900 200 L 40 40 1 1 W X DRDY\ 17 600 -300 200 L 40 40 1 1 O X DSYNC\ 9 -600 -300 200 R 40 40 1 1 I X DVDD 13 600 -600 200 L 40 40 1 1 W X MODE 18 -600 -400 200 R 40 40 1 1 I X REFIN 21 -600 -100 200 R 40 40 1 1 I X REFOUT 20 600 -100 200 L 40 40 1 1 O X SCLK 14 -600 -700 200 R 40 40 1 1 B X SDIO 15 -600 -800 200 R 40 40 1 1 B X SDOUT 16 600 800 200 L 40 40 1 1 O X VBIAS 7 600 0 200 L 40 40 1 1 O X XIN 10 -600 -200 200 R 40 40 1 1 I X XOUT 11 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1212P # Package Name: DIL18 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1212P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1212 F0 "IC" -400 625 50 H V L B F1 "ADS1212P" -400 -800 50 H V L B F2 "burr-brown-DIL18" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 400 -700 P 2 1 0 0 400 -700 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X AGND 3 600 -500 200 L 40 40 1 1 W X AINN 2 -600 400 200 R 40 40 1 1 I X AINP 1 -600 500 200 R 40 40 1 1 I X AVDD 16 600 -200 200 L 40 40 1 1 W X CS\ 5 -600 -200 200 R 40 40 1 1 I X DGND 9 600 -600 200 L 40 40 1 1 W X DRDY\ 14 600 0 200 L 40 40 1 1 O X DSYNC\ 6 -600 0 200 R 40 40 1 1 I X DVDD 10 600 -300 200 L 40 40 1 1 W X MODE 15 -600 -100 200 R 40 40 1 1 I X REFIN 18 -600 200 200 R 40 40 1 1 I X REFOUT 17 600 200 200 L 40 40 1 1 O X SCLK 11 -600 -400 200 R 40 40 1 1 B X SDIO 12 -600 -500 200 R 40 40 1 1 B X SDOUT 13 600 500 200 L 40 40 1 1 O X VBIAS 4 600 300 200 L 40 40 1 1 O X XIN 7 -600 100 200 R 40 40 1 1 I X XOUT 8 600 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1212U # Package Name: SO18L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1212U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1212 F0 "IC" -400 625 50 H V L B F1 "ADS1212U" -400 -800 50 H V L B F2 "burr-brown-SO18L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 400 -700 P 2 1 0 0 400 -700 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X AGND 3 600 -500 200 L 40 40 1 1 W X AINN 2 -600 400 200 R 40 40 1 1 I X AINP 1 -600 500 200 R 40 40 1 1 I X AVDD 16 600 -200 200 L 40 40 1 1 W X CS\ 5 -600 -200 200 R 40 40 1 1 I X DGND 9 600 -600 200 L 40 40 1 1 W X DRDY\ 14 600 0 200 L 40 40 1 1 O X DSYNC\ 6 -600 0 200 R 40 40 1 1 I X DVDD 10 600 -300 200 L 40 40 1 1 W X MODE 15 -600 -100 200 R 40 40 1 1 I X REFIN 18 -600 200 200 R 40 40 1 1 I X REFOUT 17 600 200 200 L 40 40 1 1 O X SCLK 11 -600 -400 200 R 40 40 1 1 B X SDIO 12 -600 -500 200 R 40 40 1 1 B X SDOUT 13 600 500 200 L 40 40 1 1 O X VBIAS 4 600 300 200 L 40 40 1 1 O X XIN 7 -600 100 200 R 40 40 1 1 I X XOUT 8 600 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1213E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1213E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1213 F0 "IC" -400 925 50 H V L B F1 "ADS1213E" -400 -1100 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 400 -1000 P 2 1 0 0 400 -1000 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X AGND 6 600 -800 200 L 40 40 1 1 W X AIN1N 5 -600 700 200 R 40 40 1 1 I X AIN1P 4 -600 800 200 R 40 40 1 1 I X AIN2N 3 -600 500 200 R 40 40 1 1 I X AIN2P 2 -600 600 200 R 40 40 1 1 I X AIN3N 1 -600 300 200 R 40 40 1 1 I X AIN3P 28 -600 400 200 R 40 40 1 1 I X AIN4N 27 -600 100 200 R 40 40 1 1 I X AIN4P 26 -600 200 200 R 40 40 1 1 I X AVDD 23 600 -500 200 L 40 40 1 1 W X CS\ 10 -600 -300 200 R 40 40 1 1 I X DGND 14 600 -900 200 L 40 40 1 1 W X DRDY\ 19 600 -300 200 L 40 40 1 1 O X DSYNC\ 11 -600 -500 200 R 40 40 1 1 I X DVDD 15 600 -600 200 L 40 40 1 1 W X MODE 22 -600 -400 200 R 40 40 1 1 I X REFIN 25 -600 -100 200 R 40 40 1 1 I X REFOUT 24 600 -100 200 L 40 40 1 1 O X SCLK 16 -600 -800 200 R 40 40 1 1 B X SDIO 17 -600 -900 200 R 40 40 1 1 B X SDOUT 18 600 800 200 L 40 40 1 1 O X VBIAS 7 600 600 200 L 40 40 1 1 O X XIN 12 -600 -200 200 R 40 40 1 1 I X XOUT 13 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1213P # Package Name: DIL24-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1213P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1213 F0 "IC" -400 925 50 H V L B F1 "ADS1213P" -400 -1100 50 H V L B F2 "burr-brown-DIL24-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 400 -1000 P 2 1 0 0 400 -1000 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X AGND 6 600 -800 200 L 40 40 1 1 W X AIN1N 5 -600 700 200 R 40 40 1 1 I X AIN1P 4 -600 800 200 R 40 40 1 1 I X AIN2N 3 -600 500 200 R 40 40 1 1 I X AIN2P 2 -600 600 200 R 40 40 1 1 I X AIN3N 1 -600 300 200 R 40 40 1 1 I X AIN3P 24 -600 400 200 R 40 40 1 1 I X AIN4N 23 -600 100 200 R 40 40 1 1 I X AIN4P 22 -600 200 200 R 40 40 1 1 I X AVDD 19 600 -500 200 L 40 40 1 1 W X CS\ 8 -600 -300 200 R 40 40 1 1 I X DGND 12 600 -900 200 L 40 40 1 1 W X DRDY\ 17 600 -300 200 L 40 40 1 1 O X DSYNC\ 9 -600 -500 200 R 40 40 1 1 I X DVDD 13 600 -600 200 L 40 40 1 1 W X MODE 18 -600 -400 200 R 40 40 1 1 I X REFIN 21 -600 -100 200 R 40 40 1 1 I X REFOUT 20 600 -100 200 L 40 40 1 1 O X SCLK 14 -600 -800 200 R 40 40 1 1 B X SDIO 15 -600 -900 200 R 40 40 1 1 B X SDOUT 16 600 800 200 L 40 40 1 1 O X VBIAS 7 600 600 200 L 40 40 1 1 O X XIN 10 -600 -200 200 R 40 40 1 1 I X XOUT 11 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1213U # Package Name: SO24L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1213U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS1213 F0 "IC" -400 925 50 H V L B F1 "ADS1213U" -400 -1100 50 H V L B F2 "burr-brown-SO24L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 400 -1000 P 2 1 0 0 400 -1000 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X AGND 6 600 -800 200 L 40 40 1 1 W X AIN1N 5 -600 700 200 R 40 40 1 1 I X AIN1P 4 -600 800 200 R 40 40 1 1 I X AIN2N 3 -600 500 200 R 40 40 1 1 I X AIN2P 2 -600 600 200 R 40 40 1 1 I X AIN3N 1 -600 300 200 R 40 40 1 1 I X AIN3P 24 -600 400 200 R 40 40 1 1 I X AIN4N 23 -600 100 200 R 40 40 1 1 I X AIN4P 22 -600 200 200 R 40 40 1 1 I X AVDD 19 600 -500 200 L 40 40 1 1 W X CS\ 8 -600 -300 200 R 40 40 1 1 I X DGND 12 600 -900 200 L 40 40 1 1 W X DRDY\ 17 600 -300 200 L 40 40 1 1 O X DSYNC\ 9 -600 -500 200 R 40 40 1 1 I X DVDD 13 600 -600 200 L 40 40 1 1 W X MODE 18 -600 -400 200 R 40 40 1 1 I X REFIN 21 -600 -100 200 R 40 40 1 1 I X REFOUT 20 600 -100 200 L 40 40 1 1 O X SCLK 14 -600 -800 200 R 40 40 1 1 B X SDIO 15 -600 -900 200 R 40 40 1 1 B X SDOUT 16 600 800 200 L 40 40 1 1 O X VBIAS 7 600 600 200 L 40 40 1 1 O X XIN 10 -600 -200 200 R 40 40 1 1 I X XOUT 11 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ADS1286P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1286P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS1286P" -300 -400 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS1286U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS1286U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS1286U" -300 -400 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7800P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7800P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7800 F0 "IC" -300 1225 50 H V L B F1 "ADS7800P" -300 -1200 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1200 P 2 1 0 0 -300 1200 300 1200 P 2 1 0 0 300 1200 300 -1100 X -VS 22 500 -700 200 L 40 40 1 1 W X AGND 4 500 -900 200 L 40 40 1 1 W X BUSY\ 21 500 -300 200 L 40 40 1 1 O X CS\ 20 -500 600 200 R 40 40 1 1 I X D0 17 500 1100 200 L 40 40 1 1 O X D1 16 500 1000 200 L 40 40 1 1 O X D2 15 500 900 200 L 40 40 1 1 O X D3 14 500 800 200 L 40 40 1 1 O X D4 12 500 700 200 L 40 40 1 1 O X D5 11 500 600 200 L 40 40 1 1 O X D6 10 500 500 200 L 40 40 1 1 O X D7 9 500 400 200 L 40 40 1 1 O X D8 8 500 300 200 L 40 40 1 1 O X D9 7 500 200 200 L 40 40 1 1 O X D10 6 500 100 200 L 40 40 1 1 O X D11 5 500 0 200 L 40 40 1 1 O X DGND 13 500 -1000 200 L 40 40 1 1 W X HBE 18 -500 800 200 R 40 40 1 1 I X IN1 1 -500 1100 200 R 40 40 1 1 I X IN2 2 -500 1000 200 R 40 40 1 1 I X R/C\ 19 -500 700 200 R 40 40 1 1 I X REF 3 500 -200 200 L 40 40 1 1 O X VSA 24 500 -500 200 L 40 40 1 1 W X VSD 23 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7800U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7800U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7800 F0 "IC" -300 1225 50 H V L B F1 "ADS7800U" -300 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1200 P 2 1 0 0 -300 1200 300 1200 P 2 1 0 0 300 1200 300 -1100 X -VS 22 500 -700 200 L 40 40 1 1 W X AGND 4 500 -900 200 L 40 40 1 1 W X BUSY\ 21 500 -300 200 L 40 40 1 1 O X CS\ 20 -500 600 200 R 40 40 1 1 I X D0 17 500 1100 200 L 40 40 1 1 O X D1 16 500 1000 200 L 40 40 1 1 O X D2 15 500 900 200 L 40 40 1 1 O X D3 14 500 800 200 L 40 40 1 1 O X D4 12 500 700 200 L 40 40 1 1 O X D5 11 500 600 200 L 40 40 1 1 O X D6 10 500 500 200 L 40 40 1 1 O X D7 9 500 400 200 L 40 40 1 1 O X D8 8 500 300 200 L 40 40 1 1 O X D9 7 500 200 200 L 40 40 1 1 O X D10 6 500 100 200 L 40 40 1 1 O X D11 5 500 0 200 L 40 40 1 1 O X DGND 13 500 -1000 200 L 40 40 1 1 W X HBE 18 -500 800 200 R 40 40 1 1 I X IN1 1 -500 1100 200 R 40 40 1 1 I X IN2 2 -500 1000 200 R 40 40 1 1 I X R/C\ 19 -500 700 200 R 40 40 1 1 I X REF 3 500 -200 200 L 40 40 1 1 O X VSA 24 500 -500 200 L 40 40 1 1 W X VSD 23 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7803P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF ADS7803P IC 0 40 Y Y 2 L N # Gate Name: G # Symbol Name: ADS7803 F0 "IC" -400 950 50 H V L B F1 "ADS7803P" -400 -1000 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -400 900 -400 -900 P 2 1 0 0 -400 -900 400 -900 P 2 1 0 0 400 -900 400 900 P 2 1 0 0 400 900 -400 900 X /BUSY 22 -500 0 100 R 40 40 1 1 I X /CAL 26 -500 -200 100 R 40 40 1 1 I X /CS 19 500 -700 100 L 40 40 1 1 I X /RD 18 500 -600 100 L 40 40 1 1 I X /WR 20 500 -500 100 L 40 40 1 1 I X A0 24 500 -300 100 L 40 40 1 1 I X A1 25 500 -200 100 L 40 40 1 1 I X AGND 27 -500 -800 100 R 40 40 1 1 W X AIN0 2 -500 600 100 R 40 40 1 1 I X AIN1 3 -500 500 100 R 40 40 1 1 I X AIN2 4 -500 400 100 R 40 40 1 1 I X AIN3 5 -500 300 100 R 40 40 1 1 I X CLK 23 -500 800 100 R 40 40 1 1 I C X D0 17 500 100 100 L 40 40 1 1 T X D1 16 500 200 100 L 40 40 1 1 T X D2 15 500 300 100 L 40 40 1 1 T X D3 14 500 400 100 L 40 40 1 1 T X D4 13 500 500 100 L 40 40 1 1 T X D5 12 500 600 100 L 40 40 1 1 T X D6 11 500 700 100 L 40 40 1 1 T X D7 10 500 800 100 L 40 40 1 1 T X HBE 21 -500 -100 100 R 40 40 1 1 I X SFR 1 -500 -300 100 R 40 40 1 1 I X VD 9 -500 100 100 R 40 40 1 1 B X VREF+ 6 -500 -500 100 R 40 40 1 1 B X VREF- 7 -500 -600 100 R 40 40 1 1 B # Gate Name: P # Symbol Name: PWRN T 1 50 -155 50 0 2 0 GND T 1 50 175 50 0 2 0 VCC X GND 8 0 -300 200 U 40 40 2 1 W X VCC 28 0 300 200 D 40 40 2 1 W ENDDRAW ENDDEF # # Dev Name: ADS7804P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7804P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7804 F0 "IC" -300 1325 50 H V L B F1 "ADS7804P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X AGND1 2 500 -1000 200 L 40 40 1 1 W X AGND2 5 500 -1100 200 L 40 40 1 1 W X B0 22 500 1200 200 L 40 40 1 1 O X B1 21 500 1100 200 L 40 40 1 1 O X B2 20 500 1000 200 L 40 40 1 1 O X B3 19 500 900 200 L 40 40 1 1 O X B4 18 500 800 200 L 40 40 1 1 O X B5 17 500 700 200 L 40 40 1 1 O X B6 16 500 600 200 L 40 40 1 1 O X B7 15 500 500 200 L 40 40 1 1 O X B8 13 500 400 200 L 40 40 1 1 O X B9 12 500 300 200 L 40 40 1 1 O X B10 11 500 200 200 L 40 40 1 1 O X B11 10 500 100 200 L 40 40 1 1 O X B12 9 500 0 200 L 40 40 1 1 O X B13 8 500 -100 200 L 40 40 1 1 O X B14 7 500 -200 200 L 40 40 1 1 O X B15 6 500 -300 200 L 40 40 1 1 O X BUSY\ 26 500 -500 200 L 40 40 1 1 O X BYTE 23 -500 1000 200 R 40 40 1 1 I X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 25 -500 800 200 R 40 40 1 1 I X DGND 14 500 -1200 200 L 40 40 1 1 W X IN 1 -500 1200 200 R 40 40 1 1 I X R/C\ 24 -500 900 200 R 40 40 1 1 I X REF 3 -500 600 200 R 40 40 1 1 B X VANA 27 500 -700 200 L 40 40 1 1 W X VDIG 28 500 -800 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7805P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7805P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7821 F0 "IC" -300 1425 50 H V L B F1 "ADS7805P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1400 P 2 1 0 0 -300 1400 300 1400 P 2 1 0 0 300 1400 300 -1300 X AGND1 2 500 -1000 200 L 40 40 1 1 W X AGND2 5 500 -1100 200 L 40 40 1 1 W X BUSY\ 26 500 -500 200 L 40 40 1 1 O X BYTE 23 -500 1100 200 R 40 40 1 1 I X CAP 4 -500 300 200 R 40 40 1 1 P X CS\ 25 -500 700 200 R 40 40 1 1 I X D0 22 500 1300 200 L 40 40 1 1 O X D1 21 500 1200 200 L 40 40 1 1 O X D2 20 500 1100 200 L 40 40 1 1 O X D3 19 500 1000 200 L 40 40 1 1 O X D4 18 500 900 200 L 40 40 1 1 O X D5 17 500 800 200 L 40 40 1 1 O X D6 16 500 700 200 L 40 40 1 1 O X D7 15 500 600 200 L 40 40 1 1 O X D8 13 500 400 200 L 40 40 1 1 O X D9 12 500 300 200 L 40 40 1 1 O X D10 11 500 200 200 L 40 40 1 1 O X D11 10 500 100 200 L 40 40 1 1 O X D12 9 500 0 200 L 40 40 1 1 O X D13 8 500 -100 200 L 40 40 1 1 O X D14 7 500 -200 200 L 40 40 1 1 O X D15 6 500 -300 200 L 40 40 1 1 O X DGND 14 500 -1200 200 L 40 40 1 1 W X R/C\ 24 -500 900 200 R 40 40 1 1 I X REF 3 -500 500 200 R 40 40 1 1 B X VANA 27 500 -700 200 L 40 40 1 1 W X VDIG 28 500 -800 200 L 40 40 1 1 W X VIN 1 -500 1300 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7805U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7805U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7821 F0 "IC" -300 1425 50 H V L B F1 "ADS7805U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1400 P 2 1 0 0 -300 1400 300 1400 P 2 1 0 0 300 1400 300 -1300 X AGND1 2 500 -1000 200 L 40 40 1 1 W X AGND2 5 500 -1100 200 L 40 40 1 1 W X BUSY\ 26 500 -500 200 L 40 40 1 1 O X BYTE 23 -500 1100 200 R 40 40 1 1 I X CAP 4 -500 300 200 R 40 40 1 1 P X CS\ 25 -500 700 200 R 40 40 1 1 I X D0 22 500 1300 200 L 40 40 1 1 O X D1 21 500 1200 200 L 40 40 1 1 O X D2 20 500 1100 200 L 40 40 1 1 O X D3 19 500 1000 200 L 40 40 1 1 O X D4 18 500 900 200 L 40 40 1 1 O X D5 17 500 800 200 L 40 40 1 1 O X D6 16 500 700 200 L 40 40 1 1 O X D7 15 500 600 200 L 40 40 1 1 O X D8 13 500 400 200 L 40 40 1 1 O X D9 12 500 300 200 L 40 40 1 1 O X D10 11 500 200 200 L 40 40 1 1 O X D11 10 500 100 200 L 40 40 1 1 O X D12 9 500 0 200 L 40 40 1 1 O X D13 8 500 -100 200 L 40 40 1 1 O X D14 7 500 -200 200 L 40 40 1 1 O X D15 6 500 -300 200 L 40 40 1 1 O X DGND 14 500 -1200 200 L 40 40 1 1 W X R/C\ 24 -500 900 200 R 40 40 1 1 I X REF 3 -500 500 200 R 40 40 1 1 B X VANA 27 500 -700 200 L 40 40 1 1 W X VDIG 28 500 -800 200 L 40 40 1 1 W X VIN 1 -500 1300 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7806P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7806P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7806 F0 "IC" -400 1025 50 H V L B F1 "ADS7806P" -400 -1100 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1000 400 1000 P 2 1 0 0 400 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1000 P 2 1 0 0 -400 -1000 400 -1000 X AGND1 2 600 -700 200 L 40 40 1 1 W X AGND2 6 600 -800 200 L 40 40 1 1 W X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 300 200 R 40 40 1 1 I X CAP 4 -600 -500 200 R 40 40 1 1 P X CS\ 23 -600 100 200 R 40 40 1 1 I X D0 17 600 900 200 L 40 40 1 1 O X D1 16 600 800 200 L 40 40 1 1 O X D2 15 600 700 200 L 40 40 1 1 O X D3 13 600 600 200 L 40 40 1 1 O X D4 12 600 500 200 L 40 40 1 1 O X D5 11 600 400 200 L 40 40 1 1 O X D6 10 600 300 200 L 40 40 1 1 O X D7 9 600 200 200 L 40 40 1 1 O X DATACLK 18 -600 -300 200 R 40 40 1 1 B X DGND 14 600 -900 200 L 40 40 1 1 W X EXT/INT\ 8 -600 500 200 R 40 40 1 1 I X PWRD 25 -600 0 200 R 40 40 1 1 I X R/C\ 22 -600 200 200 R 40 40 1 1 I X R1IN 1 -600 900 200 R 40 40 1 1 I X R2IN 3 -600 800 200 R 40 40 1 1 I X REF 5 600 -200 200 L 40 40 1 1 O X REFD 26 -600 -100 200 R 40 40 1 1 I X SB/PTC\ 7 -600 600 200 R 40 40 1 1 I X SDATA 19 600 0 200 L 40 40 1 1 O X TAG 20 -600 400 200 R 40 40 1 1 I X VANA 27 600 -400 200 L 40 40 1 1 W X VDIG 28 600 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7806U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7806U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7806 F0 "IC" -400 1025 50 H V L B F1 "ADS7806U" -400 -1100 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1000 400 1000 P 2 1 0 0 400 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1000 P 2 1 0 0 -400 -1000 400 -1000 X AGND1 2 600 -700 200 L 40 40 1 1 W X AGND2 6 600 -800 200 L 40 40 1 1 W X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 300 200 R 40 40 1 1 I X CAP 4 -600 -500 200 R 40 40 1 1 P X CS\ 23 -600 100 200 R 40 40 1 1 I X D0 17 600 900 200 L 40 40 1 1 O X D1 16 600 800 200 L 40 40 1 1 O X D2 15 600 700 200 L 40 40 1 1 O X D3 13 600 600 200 L 40 40 1 1 O X D4 12 600 500 200 L 40 40 1 1 O X D5 11 600 400 200 L 40 40 1 1 O X D6 10 600 300 200 L 40 40 1 1 O X D7 9 600 200 200 L 40 40 1 1 O X DATACLK 18 -600 -300 200 R 40 40 1 1 B X DGND 14 600 -900 200 L 40 40 1 1 W X EXT/INT\ 8 -600 500 200 R 40 40 1 1 I X PWRD 25 -600 0 200 R 40 40 1 1 I X R/C\ 22 -600 200 200 R 40 40 1 1 I X R1IN 1 -600 900 200 R 40 40 1 1 I X R2IN 3 -600 800 200 R 40 40 1 1 I X REF 5 600 -200 200 L 40 40 1 1 O X REFD 26 -600 -100 200 R 40 40 1 1 I X SB/PTC\ 7 -600 600 200 R 40 40 1 1 I X SDATA 19 600 0 200 L 40 40 1 1 O X TAG 20 -600 400 200 R 40 40 1 1 I X VANA 27 600 -400 200 L 40 40 1 1 W X VDIG 28 600 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7807P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7807P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7806 F0 "IC" -400 1025 50 H V L B F1 "ADS7807P" -400 -1100 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1000 400 1000 P 2 1 0 0 400 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1000 P 2 1 0 0 -400 -1000 400 -1000 X AGND1 2 600 -700 200 L 40 40 1 1 W X AGND2 6 600 -800 200 L 40 40 1 1 W X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 300 200 R 40 40 1 1 I X CAP 4 -600 -500 200 R 40 40 1 1 P X CS\ 23 -600 100 200 R 40 40 1 1 I X D0 17 600 900 200 L 40 40 1 1 O X D1 16 600 800 200 L 40 40 1 1 O X D2 15 600 700 200 L 40 40 1 1 O X D3 13 600 600 200 L 40 40 1 1 O X D4 12 600 500 200 L 40 40 1 1 O X D5 11 600 400 200 L 40 40 1 1 O X D6 10 600 300 200 L 40 40 1 1 O X D7 9 600 200 200 L 40 40 1 1 O X DATACLK 18 -600 -300 200 R 40 40 1 1 B X DGND 14 600 -900 200 L 40 40 1 1 W X EXT/INT\ 8 -600 500 200 R 40 40 1 1 I X PWRD 25 -600 0 200 R 40 40 1 1 I X R/C\ 22 -600 200 200 R 40 40 1 1 I X R1IN 1 -600 900 200 R 40 40 1 1 I X R2IN 3 -600 800 200 R 40 40 1 1 I X REF 5 600 -200 200 L 40 40 1 1 O X REFD 26 -600 -100 200 R 40 40 1 1 I X SB/PTC\ 7 -600 600 200 R 40 40 1 1 I X SDATA 19 600 0 200 L 40 40 1 1 O X TAG 20 -600 400 200 R 40 40 1 1 I X VANA 27 600 -400 200 L 40 40 1 1 W X VDIG 28 600 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7807U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7807U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7806 F0 "IC" -400 1025 50 H V L B F1 "ADS7807U" -400 -1100 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1000 400 1000 P 2 1 0 0 400 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1000 P 2 1 0 0 -400 -1000 400 -1000 X AGND1 2 600 -700 200 L 40 40 1 1 W X AGND2 6 600 -800 200 L 40 40 1 1 W X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 300 200 R 40 40 1 1 I X CAP 4 -600 -500 200 R 40 40 1 1 P X CS\ 23 -600 100 200 R 40 40 1 1 I X D0 17 600 900 200 L 40 40 1 1 O X D1 16 600 800 200 L 40 40 1 1 O X D2 15 600 700 200 L 40 40 1 1 O X D3 13 600 600 200 L 40 40 1 1 O X D4 12 600 500 200 L 40 40 1 1 O X D5 11 600 400 200 L 40 40 1 1 O X D6 10 600 300 200 L 40 40 1 1 O X D7 9 600 200 200 L 40 40 1 1 O X DATACLK 18 -600 -300 200 R 40 40 1 1 B X DGND 14 600 -900 200 L 40 40 1 1 W X EXT/INT\ 8 -600 500 200 R 40 40 1 1 I X PWRD 25 -600 0 200 R 40 40 1 1 I X R/C\ 22 -600 200 200 R 40 40 1 1 I X R1IN 1 -600 900 200 R 40 40 1 1 I X R2IN 3 -600 800 200 R 40 40 1 1 I X REF 5 600 -200 200 L 40 40 1 1 O X REFD 26 -600 -100 200 R 40 40 1 1 I X SB/PTC\ 7 -600 600 200 R 40 40 1 1 I X SDATA 19 600 0 200 L 40 40 1 1 O X TAG 20 -600 400 200 R 40 40 1 1 I X VANA 27 600 -400 200 L 40 40 1 1 W X VDIG 28 600 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7809P # Package Name: DIL20 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7809P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7809 F0 "IC" -400 825 50 H V L B F1 "ADS7809P" -400 -900 50 H V L B F2 "burr-brown-DIL20" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 -400 800 P 2 1 0 0 -400 800 300 800 P 2 1 0 0 300 800 300 -800 P 2 1 0 0 300 -800 -400 -800 X AGND1 2 500 -500 200 L 40 40 1 1 W X AGND2 7 500 -600 200 L 40 40 1 1 W X BUSY\ 17 500 400 200 L 40 40 1 1 O X CAP 5 -600 -700 200 R 40 40 1 1 P X CS\ 16 -600 -100 200 R 40 40 1 1 I X DATA 13 500 700 200 L 40 40 1 1 O X DATACLK 12 -600 -400 200 R 40 40 1 1 B X DGND 10 500 -700 200 L 40 40 1 1 W X EXT/INT\ 9 -600 200 200 R 40 40 1 1 I X PWRD 18 -600 -200 200 R 40 40 1 1 I X R/C\ 15 -600 0 200 R 40 40 1 1 I X R1IN 1 -600 700 200 R 40 40 1 1 I X R2IN 3 -600 600 200 R 40 40 1 1 I X R3IN 4 -600 500 200 R 40 40 1 1 I X REF 6 -600 -500 200 R 40 40 1 1 B X SB/BTC\ 8 -600 300 200 R 40 40 1 1 I X SYNC 11 500 500 200 L 40 40 1 1 O X TAG 14 -600 100 200 R 40 40 1 1 I X VANA 19 500 -200 200 L 40 40 1 1 W X VDIG 20 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7809U # Package Name: SO20L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7809U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7809 F0 "IC" -400 825 50 H V L B F1 "ADS7809U" -400 -900 50 H V L B F2 "burr-brown-SO20L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 -400 800 P 2 1 0 0 -400 800 300 800 P 2 1 0 0 300 800 300 -800 P 2 1 0 0 300 -800 -400 -800 X AGND1 2 500 -500 200 L 40 40 1 1 W X AGND2 7 500 -600 200 L 40 40 1 1 W X BUSY\ 17 500 400 200 L 40 40 1 1 O X CAP 5 -600 -700 200 R 40 40 1 1 P X CS\ 16 -600 -100 200 R 40 40 1 1 I X DATA 13 500 700 200 L 40 40 1 1 O X DATACLK 12 -600 -400 200 R 40 40 1 1 B X DGND 10 500 -700 200 L 40 40 1 1 W X EXT/INT\ 9 -600 200 200 R 40 40 1 1 I X PWRD 18 -600 -200 200 R 40 40 1 1 I X R/C\ 15 -600 0 200 R 40 40 1 1 I X R1IN 1 -600 700 200 R 40 40 1 1 I X R2IN 3 -600 600 200 R 40 40 1 1 I X R3IN 4 -600 500 200 R 40 40 1 1 I X REF 6 -600 -500 200 R 40 40 1 1 B X SB/BTC\ 8 -600 300 200 R 40 40 1 1 I X SYNC 11 500 500 200 L 40 40 1 1 O X TAG 14 -600 100 200 R 40 40 1 1 I X VANA 19 500 -200 200 L 40 40 1 1 W X VDIG 20 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7810P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7810P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7819 F0 "IC" -300 1325 50 H V L B F1 "ADS7810P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X +VANA 20 500 -300 200 L 40 40 1 1 W X +VANA@1 28 500 -400 200 L 40 40 1 1 W X +VDIG 21 500 -600 200 L 40 40 1 1 W X +VDIG@1 27 500 -700 200 L 40 40 1 1 W X -VANA 26 500 -500 200 L 40 40 1 1 W X AGND1 2 500 -900 200 L 40 40 1 1 W X AGND2 5 500 -1000 200 L 40 40 1 1 W X BUSY\ 25 500 -100 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 24 -500 800 200 R 40 40 1 1 I X D0 18 500 1200 200 L 40 40 1 1 O X D1 17 500 1100 200 L 40 40 1 1 O X D2 16 500 1000 200 L 40 40 1 1 O X D3 15 500 900 200 L 40 40 1 1 O X D4 13 500 800 200 L 40 40 1 1 O X D5 12 500 700 200 L 40 40 1 1 O X D6 11 500 600 200 L 40 40 1 1 O X D7 10 500 500 200 L 40 40 1 1 O X D8 9 500 400 200 L 40 40 1 1 O X D9 8 500 300 200 L 40 40 1 1 O X D10 7 500 200 200 L 40 40 1 1 O X D11 6 500 100 200 L 40 40 1 1 O X DGND 14 500 -1100 200 L 40 40 1 1 W X DGND@1 22 500 -1200 200 L 40 40 1 1 W X NC 19 -500 600 200 R 40 40 1 1 U X R/C\ 23 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7810U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7810U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7819 F0 "IC" -300 1325 50 H V L B F1 "ADS7810U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X +VANA 20 500 -300 200 L 40 40 1 1 W X +VANA@1 28 500 -400 200 L 40 40 1 1 W X +VDIG 21 500 -600 200 L 40 40 1 1 W X +VDIG@1 27 500 -700 200 L 40 40 1 1 W X -VANA 26 500 -500 200 L 40 40 1 1 W X AGND1 2 500 -900 200 L 40 40 1 1 W X AGND2 5 500 -1000 200 L 40 40 1 1 W X BUSY\ 25 500 -100 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 24 -500 800 200 R 40 40 1 1 I X D0 18 500 1200 200 L 40 40 1 1 O X D1 17 500 1100 200 L 40 40 1 1 O X D2 16 500 1000 200 L 40 40 1 1 O X D3 15 500 900 200 L 40 40 1 1 O X D4 13 500 800 200 L 40 40 1 1 O X D5 12 500 700 200 L 40 40 1 1 O X D6 11 500 600 200 L 40 40 1 1 O X D7 10 500 500 200 L 40 40 1 1 O X D8 9 500 400 200 L 40 40 1 1 O X D9 8 500 300 200 L 40 40 1 1 O X D10 7 500 200 200 L 40 40 1 1 O X D11 6 500 100 200 L 40 40 1 1 O X DGND 14 500 -1100 200 L 40 40 1 1 W X DGND@1 22 500 -1200 200 L 40 40 1 1 W X NC 19 -500 600 200 R 40 40 1 1 U X R/C\ 23 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7812P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7812P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7812 F0 "IC" -400 625 50 H V L B F1 "ADS7812P" -400 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X BUF 5 600 100 200 L 40 40 1 1 O X BUSY\ 14 600 300 200 L 40 40 1 1 O X CAP 6 -600 -500 200 R 40 40 1 1 P X CONV\ 12 -600 0 200 R 40 40 1 1 I X CS\ 13 -600 -100 200 R 40 40 1 1 I X DATA 10 600 500 200 L 40 40 1 1 O X DATACLK 9 -600 -400 200 R 40 40 1 1 B X EXT/INT\ 11 -600 -200 200 R 40 40 1 1 I X GND 2 600 -400 200 L 40 40 1 1 W X GND@1 8 600 -500 200 L 40 40 1 1 W X PWRD 15 -600 100 200 R 40 40 1 1 I X R1IN 1 -600 500 200 R 40 40 1 1 I X R2IN 3 -600 400 200 R 40 40 1 1 I X R3IN 4 -600 300 200 R 40 40 1 1 I X REF 7 -600 -300 200 R 40 40 1 1 B X VS 16 600 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7812U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7812U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7812 F0 "IC" -400 625 50 H V L B F1 "ADS7812U" -400 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X BUF 5 600 100 200 L 40 40 1 1 O X BUSY\ 14 600 300 200 L 40 40 1 1 O X CAP 6 -600 -500 200 R 40 40 1 1 P X CONV\ 12 -600 0 200 R 40 40 1 1 I X CS\ 13 -600 -100 200 R 40 40 1 1 I X DATA 10 600 500 200 L 40 40 1 1 O X DATACLK 9 -600 -400 200 R 40 40 1 1 B X EXT/INT\ 11 -600 -200 200 R 40 40 1 1 I X GND 2 600 -400 200 L 40 40 1 1 W X GND@1 8 600 -500 200 L 40 40 1 1 W X PWRD 15 -600 100 200 R 40 40 1 1 I X R1IN 1 -600 500 200 R 40 40 1 1 I X R2IN 3 -600 400 200 R 40 40 1 1 I X R3IN 4 -600 300 200 R 40 40 1 1 I X REF 7 -600 -300 200 R 40 40 1 1 B X VS 16 600 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7813P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7813P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7812 F0 "IC" -400 625 50 H V L B F1 "ADS7813P" -400 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X BUF 5 600 100 200 L 40 40 1 1 O X BUSY\ 14 600 300 200 L 40 40 1 1 O X CAP 6 -600 -500 200 R 40 40 1 1 P X CONV\ 12 -600 0 200 R 40 40 1 1 I X CS\ 13 -600 -100 200 R 40 40 1 1 I X DATA 10 600 500 200 L 40 40 1 1 O X DATACLK 9 -600 -400 200 R 40 40 1 1 B X EXT/INT\ 11 -600 -200 200 R 40 40 1 1 I X GND 2 600 -400 200 L 40 40 1 1 W X GND@1 8 600 -500 200 L 40 40 1 1 W X PWRD 15 -600 100 200 R 40 40 1 1 I X R1IN 1 -600 500 200 R 40 40 1 1 I X R2IN 3 -600 400 200 R 40 40 1 1 I X R3IN 4 -600 300 200 R 40 40 1 1 I X REF 7 -600 -300 200 R 40 40 1 1 B X VS 16 600 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7813U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7813U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7812 F0 "IC" -400 625 50 H V L B F1 "ADS7813U" -400 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X BUF 5 600 100 200 L 40 40 1 1 O X BUSY\ 14 600 300 200 L 40 40 1 1 O X CAP 6 -600 -500 200 R 40 40 1 1 P X CONV\ 12 -600 0 200 R 40 40 1 1 I X CS\ 13 -600 -100 200 R 40 40 1 1 I X DATA 10 600 500 200 L 40 40 1 1 O X DATACLK 9 -600 -400 200 R 40 40 1 1 B X EXT/INT\ 11 -600 -200 200 R 40 40 1 1 I X GND 2 600 -400 200 L 40 40 1 1 W X GND@1 8 600 -500 200 L 40 40 1 1 W X PWRD 15 -600 100 200 R 40 40 1 1 I X R1IN 1 -600 500 200 R 40 40 1 1 I X R2IN 3 -600 400 200 R 40 40 1 1 I X R3IN 4 -600 300 200 R 40 40 1 1 I X REF 7 -600 -300 200 R 40 40 1 1 B X VS 16 600 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7815U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7815U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7815 F0 "IC" -300 1325 50 H V L B F1 "ADS7815U" -300 -1500 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1400 -300 -1400 P 2 1 0 0 -300 -1400 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1400 X +VS 27 500 -700 200 L 40 40 1 1 W X +VS@1 28 500 -800 200 L 40 40 1 1 W X -VS 23 500 -900 200 L 40 40 1 1 W X BUSY\ 26 500 -500 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 25 -500 800 200 R 40 40 1 1 I X D0 22 500 1200 200 L 40 40 1 1 O X D1 21 500 1100 200 L 40 40 1 1 O X D2 20 500 1000 200 L 40 40 1 1 O X D3 19 500 900 200 L 40 40 1 1 O X D4 18 500 800 200 L 40 40 1 1 O X D5 17 500 700 200 L 40 40 1 1 O X D6 16 500 600 200 L 40 40 1 1 O X D7 15 500 500 200 L 40 40 1 1 O X D8 13 500 400 200 L 40 40 1 1 O X D9 12 500 300 200 L 40 40 1 1 O X D10 11 500 200 200 L 40 40 1 1 O X D11 10 500 100 200 L 40 40 1 1 O X D12 9 500 0 200 L 40 40 1 1 W X D13 8 500 -100 200 L 40 40 1 1 W X D14 7 500 -200 200 L 40 40 1 1 W X D15 6 500 -300 200 L 40 40 1 1 W X GND 2 500 -1100 200 L 40 40 1 1 W X GND@1 5 500 -1200 200 L 40 40 1 1 W X GND@2 14 500 -1300 200 L 40 40 1 1 W X R/C\ 24 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7816E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7816E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS7816E" -300 -400 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7816P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7816P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS7816P" -300 -400 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7816U # Package Name: SO08-GW # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7816U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS7816U" -300 -400 50 H V L B F2 "burr-brown-SO08-GW" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7817E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7817E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS7817E" -300 -400 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7817P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7817P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS7817P" -300 -400 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7817U # Package Name: SO08-GW # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7817U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7817 F0 "IC" -300 425 50 H V L B F1 "ADS7817U" -300 -400 50 H V L B F2 "burr-brown-SO08-GW" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 400 -300 P 2 1 0 0 400 -300 400 400 P 2 1 0 0 400 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X +IN 2 -500 300 200 R 40 40 1 1 I X +VCC 8 600 0 200 L 40 40 1 1 W X -IN 3 -500 200 200 R 40 40 1 1 I X CS\/SHDN 5 -500 -100 200 R 40 40 1 1 I X DCLOCK 7 -500 -200 200 R 40 40 1 1 I X DOUT 6 600 300 200 L 40 40 1 1 O X GND 4 600 -200 200 L 40 40 1 1 W X VREF 1 -500 0 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7819P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7819P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7819 F0 "IC" -300 1325 50 H V L B F1 "ADS7819P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X +VANA 20 500 -300 200 L 40 40 1 1 W X +VANA@1 28 500 -400 200 L 40 40 1 1 W X +VDIG 21 500 -600 200 L 40 40 1 1 W X +VDIG@1 27 500 -700 200 L 40 40 1 1 W X -VANA 26 500 -500 200 L 40 40 1 1 W X AGND1 2 500 -900 200 L 40 40 1 1 W X AGND2 5 500 -1000 200 L 40 40 1 1 W X BUSY\ 25 500 -100 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 24 -500 800 200 R 40 40 1 1 I X D0 18 500 1200 200 L 40 40 1 1 O X D1 17 500 1100 200 L 40 40 1 1 O X D2 16 500 1000 200 L 40 40 1 1 O X D3 15 500 900 200 L 40 40 1 1 O X D4 13 500 800 200 L 40 40 1 1 O X D5 12 500 700 200 L 40 40 1 1 O X D6 11 500 600 200 L 40 40 1 1 O X D7 10 500 500 200 L 40 40 1 1 O X D8 9 500 400 200 L 40 40 1 1 O X D9 8 500 300 200 L 40 40 1 1 O X D10 7 500 200 200 L 40 40 1 1 O X D11 6 500 100 200 L 40 40 1 1 O X DGND 14 500 -1100 200 L 40 40 1 1 W X DGND@1 22 500 -1200 200 L 40 40 1 1 W X NC 19 -500 600 200 R 40 40 1 1 U X R/C\ 23 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7819U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7819U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7819 F0 "IC" -300 1325 50 H V L B F1 "ADS7819U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X +VANA 20 500 -300 200 L 40 40 1 1 W X +VANA@1 28 500 -400 200 L 40 40 1 1 W X +VDIG 21 500 -600 200 L 40 40 1 1 W X +VDIG@1 27 500 -700 200 L 40 40 1 1 W X -VANA 26 500 -500 200 L 40 40 1 1 W X AGND1 2 500 -900 200 L 40 40 1 1 W X AGND2 5 500 -1000 200 L 40 40 1 1 W X BUSY\ 25 500 -100 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 24 -500 800 200 R 40 40 1 1 I X D0 18 500 1200 200 L 40 40 1 1 O X D1 17 500 1100 200 L 40 40 1 1 O X D2 16 500 1000 200 L 40 40 1 1 O X D3 15 500 900 200 L 40 40 1 1 O X D4 13 500 800 200 L 40 40 1 1 O X D5 12 500 700 200 L 40 40 1 1 O X D6 11 500 600 200 L 40 40 1 1 O X D7 10 500 500 200 L 40 40 1 1 O X D8 9 500 400 200 L 40 40 1 1 O X D9 8 500 300 200 L 40 40 1 1 O X D10 7 500 200 200 L 40 40 1 1 O X D11 6 500 100 200 L 40 40 1 1 O X DGND 14 500 -1100 200 L 40 40 1 1 W X DGND@1 22 500 -1200 200 L 40 40 1 1 W X NC 19 -500 600 200 R 40 40 1 1 U X R/C\ 23 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7820P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7820P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7820 F0 "IC" -300 1125 50 H V L B F1 "ADS7820P" -300 -1200 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X AGND1 2 600 -800 200 L 40 40 1 1 W X AGND2 5 600 -900 200 L 40 40 1 1 W X BUSY\ 26 600 -300 200 L 40 40 1 1 O X BYTE 23 -500 800 200 R 40 40 1 1 I X CAP 4 -500 200 200 R 40 40 1 1 P X CS\ 25 -500 600 200 R 40 40 1 1 I X D0 18 600 1000 200 L 40 40 1 1 O X D1 17 600 900 200 L 40 40 1 1 O X D2 16 600 800 200 L 40 40 1 1 O X D3 15 600 700 200 L 40 40 1 1 O X D4 13 600 600 200 L 40 40 1 1 O X D5 12 600 500 200 L 40 40 1 1 O X D6 11 600 400 200 L 40 40 1 1 O X D7 10 600 300 200 L 40 40 1 1 O X D8 9 600 200 200 L 40 40 1 1 O X D9 8 600 100 200 L 40 40 1 1 O X D10 7 600 0 200 L 40 40 1 1 O X D11 6 600 -100 200 L 40 40 1 1 O X DGND 14 600 -1000 200 L 40 40 1 1 W X DZ 19 -500 100 200 R 40 40 1 1 P X DZ@1 20 -500 0 200 R 40 40 1 1 P X DZ@2 21 -500 -100 200 R 40 40 1 1 P X DZ@3 22 -500 -200 200 R 40 40 1 1 P X R/C\ 24 -500 700 200 R 40 40 1 1 I X REF 3 -500 400 200 R 40 40 1 1 B X VANA 27 600 -500 200 L 40 40 1 1 W X VDIG 28 600 -600 200 L 40 40 1 1 W X VIN 1 -500 1000 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7820U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7820U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7820 F0 "IC" -300 1125 50 H V L B F1 "ADS7820U" -300 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X AGND1 2 600 -800 200 L 40 40 1 1 W X AGND2 5 600 -900 200 L 40 40 1 1 W X BUSY\ 26 600 -300 200 L 40 40 1 1 O X BYTE 23 -500 800 200 R 40 40 1 1 I X CAP 4 -500 200 200 R 40 40 1 1 P X CS\ 25 -500 600 200 R 40 40 1 1 I X D0 18 600 1000 200 L 40 40 1 1 O X D1 17 600 900 200 L 40 40 1 1 O X D2 16 600 800 200 L 40 40 1 1 O X D3 15 600 700 200 L 40 40 1 1 O X D4 13 600 600 200 L 40 40 1 1 O X D5 12 600 500 200 L 40 40 1 1 O X D6 11 600 400 200 L 40 40 1 1 O X D7 10 600 300 200 L 40 40 1 1 O X D8 9 600 200 200 L 40 40 1 1 O X D9 8 600 100 200 L 40 40 1 1 O X D10 7 600 0 200 L 40 40 1 1 O X D11 6 600 -100 200 L 40 40 1 1 O X DGND 14 600 -1000 200 L 40 40 1 1 W X DZ 19 -500 100 200 R 40 40 1 1 P X DZ@1 20 -500 0 200 R 40 40 1 1 P X DZ@2 21 -500 -100 200 R 40 40 1 1 P X DZ@3 22 -500 -200 200 R 40 40 1 1 P X R/C\ 24 -500 700 200 R 40 40 1 1 I X REF 3 -500 400 200 R 40 40 1 1 B X VANA 27 600 -500 200 L 40 40 1 1 W X VDIG 28 600 -600 200 L 40 40 1 1 W X VIN 1 -500 1000 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7821P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7821P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7821 F0 "IC" -300 1425 50 H V L B F1 "ADS7821P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1400 P 2 1 0 0 -300 1400 300 1400 P 2 1 0 0 300 1400 300 -1300 X AGND1 2 500 -1000 200 L 40 40 1 1 W X AGND2 5 500 -1100 200 L 40 40 1 1 W X BUSY\ 26 500 -500 200 L 40 40 1 1 O X BYTE 23 -500 1100 200 R 40 40 1 1 I X CAP 4 -500 300 200 R 40 40 1 1 P X CS\ 25 -500 700 200 R 40 40 1 1 I X D0 22 500 1300 200 L 40 40 1 1 O X D1 21 500 1200 200 L 40 40 1 1 O X D2 20 500 1100 200 L 40 40 1 1 O X D3 19 500 1000 200 L 40 40 1 1 O X D4 18 500 900 200 L 40 40 1 1 O X D5 17 500 800 200 L 40 40 1 1 O X D6 16 500 700 200 L 40 40 1 1 O X D7 15 500 600 200 L 40 40 1 1 O X D8 13 500 400 200 L 40 40 1 1 O X D9 12 500 300 200 L 40 40 1 1 O X D10 11 500 200 200 L 40 40 1 1 O X D11 10 500 100 200 L 40 40 1 1 O X D12 9 500 0 200 L 40 40 1 1 O X D13 8 500 -100 200 L 40 40 1 1 O X D14 7 500 -200 200 L 40 40 1 1 O X D15 6 500 -300 200 L 40 40 1 1 O X DGND 14 500 -1200 200 L 40 40 1 1 W X R/C\ 24 -500 900 200 R 40 40 1 1 I X REF 3 -500 500 200 R 40 40 1 1 B X VANA 27 500 -700 200 L 40 40 1 1 W X VDIG 28 500 -800 200 L 40 40 1 1 W X VIN 1 -500 1300 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7821U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7821U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7821 F0 "IC" -300 1425 50 H V L B F1 "ADS7821U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1400 P 2 1 0 0 -300 1400 300 1400 P 2 1 0 0 300 1400 300 -1300 X AGND1 2 500 -1000 200 L 40 40 1 1 W X AGND2 5 500 -1100 200 L 40 40 1 1 W X BUSY\ 26 500 -500 200 L 40 40 1 1 O X BYTE 23 -500 1100 200 R 40 40 1 1 I X CAP 4 -500 300 200 R 40 40 1 1 P X CS\ 25 -500 700 200 R 40 40 1 1 I X D0 22 500 1300 200 L 40 40 1 1 O X D1 21 500 1200 200 L 40 40 1 1 O X D2 20 500 1100 200 L 40 40 1 1 O X D3 19 500 1000 200 L 40 40 1 1 O X D4 18 500 900 200 L 40 40 1 1 O X D5 17 500 800 200 L 40 40 1 1 O X D6 16 500 700 200 L 40 40 1 1 O X D7 15 500 600 200 L 40 40 1 1 O X D8 13 500 400 200 L 40 40 1 1 O X D9 12 500 300 200 L 40 40 1 1 O X D10 11 500 200 200 L 40 40 1 1 O X D11 10 500 100 200 L 40 40 1 1 O X D12 9 500 0 200 L 40 40 1 1 O X D13 8 500 -100 200 L 40 40 1 1 O X D14 7 500 -200 200 L 40 40 1 1 O X D15 6 500 -300 200 L 40 40 1 1 O X DGND 14 500 -1200 200 L 40 40 1 1 W X R/C\ 24 -500 900 200 R 40 40 1 1 I X REF 3 -500 500 200 R 40 40 1 1 B X VANA 27 500 -700 200 L 40 40 1 1 W X VDIG 28 500 -800 200 L 40 40 1 1 W X VIN 1 -500 1300 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7824P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7824P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7824 F0 "IC" -400 925 50 H V L B F1 "ADS7824P" -400 -1000 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -900 400 -900 P 2 1 0 0 400 -900 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -900 X A0 19 -600 300 200 R 40 40 1 1 B X A1 18 -600 200 200 R 40 40 1 1 B X AGND1 1 600 -600 200 L 40 40 1 1 W X AGND2 8 600 -700 200 L 40 40 1 1 W X AIN0 2 -600 800 200 R 40 40 1 1 I X AIN1 3 -600 700 200 R 40 40 1 1 I X AIN2 4 -600 600 200 R 40 40 1 1 I X AIN3 5 -600 500 200 R 40 40 1 1 I X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 -100 200 R 40 40 1 1 I X CAP 6 -600 -600 200 R 40 40 1 1 I X CONTC 25 -600 -400 200 R 40 40 1 1 I X CS\ 23 -600 -300 200 R 40 40 1 1 I X D0 17 600 800 200 L 40 40 1 1 B X D1 16 600 700 200 L 40 40 1 1 O X D2 15 600 600 200 L 40 40 1 1 B X D3 13 600 500 200 L 40 40 1 1 O X D4 12 600 400 200 L 40 40 1 1 B X D5 11 600 300 200 L 40 40 1 1 O X D6 10 600 200 200 L 40 40 1 1 O X D7 9 600 100 200 L 40 40 1 1 O X DGND 14 600 -800 200 L 40 40 1 1 W X PAR/SER\ 20 -600 0 200 R 40 40 1 1 I X PWRD 26 -600 -500 200 R 40 40 1 1 I X R/C\ 22 -600 -200 200 R 40 40 1 1 I X REF 7 -600 -700 200 R 40 40 1 1 B X VS1 28 600 -300 200 L 40 40 1 1 W X VS2 27 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7824U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7824U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7824 F0 "IC" -400 925 50 H V L B F1 "ADS7824U" -400 -1000 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -900 400 -900 P 2 1 0 0 400 -900 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -900 X A0 19 -600 300 200 R 40 40 1 1 B X A1 18 -600 200 200 R 40 40 1 1 B X AGND1 1 600 -600 200 L 40 40 1 1 W X AGND2 8 600 -700 200 L 40 40 1 1 W X AIN0 2 -600 800 200 R 40 40 1 1 I X AIN1 3 -600 700 200 R 40 40 1 1 I X AIN2 4 -600 600 200 R 40 40 1 1 I X AIN3 5 -600 500 200 R 40 40 1 1 I X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 -100 200 R 40 40 1 1 I X CAP 6 -600 -600 200 R 40 40 1 1 I X CONTC 25 -600 -400 200 R 40 40 1 1 I X CS\ 23 -600 -300 200 R 40 40 1 1 I X D0 17 600 800 200 L 40 40 1 1 B X D1 16 600 700 200 L 40 40 1 1 O X D2 15 600 600 200 L 40 40 1 1 B X D3 13 600 500 200 L 40 40 1 1 O X D4 12 600 400 200 L 40 40 1 1 B X D5 11 600 300 200 L 40 40 1 1 O X D6 10 600 200 200 L 40 40 1 1 O X D7 9 600 100 200 L 40 40 1 1 O X DGND 14 600 -800 200 L 40 40 1 1 W X PAR/SER\ 20 -600 0 200 R 40 40 1 1 I X PWRD 26 -600 -500 200 R 40 40 1 1 I X R/C\ 22 -600 -200 200 R 40 40 1 1 I X REF 7 -600 -700 200 R 40 40 1 1 B X VS1 28 600 -300 200 L 40 40 1 1 W X VS2 27 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7825P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7825P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7824 F0 "IC" -400 925 50 H V L B F1 "ADS7825P" -400 -1000 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -900 400 -900 P 2 1 0 0 400 -900 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -900 X A0 19 -600 300 200 R 40 40 1 1 B X A1 18 -600 200 200 R 40 40 1 1 B X AGND1 1 600 -600 200 L 40 40 1 1 W X AGND2 8 600 -700 200 L 40 40 1 1 W X AIN0 2 -600 800 200 R 40 40 1 1 I X AIN1 3 -600 700 200 R 40 40 1 1 I X AIN2 4 -600 600 200 R 40 40 1 1 I X AIN3 5 -600 500 200 R 40 40 1 1 I X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 -100 200 R 40 40 1 1 I X CAP 6 -600 -600 200 R 40 40 1 1 I X CONTC 25 -600 -400 200 R 40 40 1 1 I X CS\ 23 -600 -300 200 R 40 40 1 1 I X D0 17 600 800 200 L 40 40 1 1 B X D1 16 600 700 200 L 40 40 1 1 O X D2 15 600 600 200 L 40 40 1 1 B X D3 13 600 500 200 L 40 40 1 1 O X D4 12 600 400 200 L 40 40 1 1 B X D5 11 600 300 200 L 40 40 1 1 O X D6 10 600 200 200 L 40 40 1 1 O X D7 9 600 100 200 L 40 40 1 1 O X DGND 14 600 -800 200 L 40 40 1 1 W X PAR/SER\ 20 -600 0 200 R 40 40 1 1 I X PWRD 26 -600 -500 200 R 40 40 1 1 I X R/C\ 22 -600 -200 200 R 40 40 1 1 I X REF 7 -600 -700 200 R 40 40 1 1 B X VS1 28 600 -300 200 L 40 40 1 1 W X VS2 27 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7825U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7825U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7824 F0 "IC" -400 925 50 H V L B F1 "ADS7825U" -400 -1000 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -900 400 -900 P 2 1 0 0 400 -900 400 900 P 2 1 0 0 400 900 -400 900 P 2 1 0 0 -400 900 -400 -900 X A0 19 -600 300 200 R 40 40 1 1 B X A1 18 -600 200 200 R 40 40 1 1 B X AGND1 1 600 -600 200 L 40 40 1 1 W X AGND2 8 600 -700 200 L 40 40 1 1 W X AIN0 2 -600 800 200 R 40 40 1 1 I X AIN1 3 -600 700 200 R 40 40 1 1 I X AIN2 4 -600 600 200 R 40 40 1 1 I X AIN3 5 -600 500 200 R 40 40 1 1 I X BUSY\ 24 600 -100 200 L 40 40 1 1 O X BYTE 21 -600 -100 200 R 40 40 1 1 I X CAP 6 -600 -600 200 R 40 40 1 1 I X CONTC 25 -600 -400 200 R 40 40 1 1 I X CS\ 23 -600 -300 200 R 40 40 1 1 I X D0 17 600 800 200 L 40 40 1 1 B X D1 16 600 700 200 L 40 40 1 1 O X D2 15 600 600 200 L 40 40 1 1 B X D3 13 600 500 200 L 40 40 1 1 O X D4 12 600 400 200 L 40 40 1 1 B X D5 11 600 300 200 L 40 40 1 1 O X D6 10 600 200 200 L 40 40 1 1 O X D7 9 600 100 200 L 40 40 1 1 O X DGND 14 600 -800 200 L 40 40 1 1 W X PAR/SER\ 20 -600 0 200 R 40 40 1 1 I X PWRD 26 -600 -500 200 R 40 40 1 1 I X R/C\ 22 -600 -200 200 R 40 40 1 1 I X REF 7 -600 -700 200 R 40 40 1 1 B X VS1 28 600 -300 200 L 40 40 1 1 W X VS2 27 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS7831P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7831P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7819 F0 "IC" -300 1325 50 H V L B F1 "ADS7831P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X +VANA 20 500 -300 200 L 40 40 1 1 W X +VANA@1 28 500 -400 200 L 40 40 1 1 W X +VDIG 21 500 -600 200 L 40 40 1 1 W X +VDIG@1 27 500 -700 200 L 40 40 1 1 W X -VANA 26 500 -500 200 L 40 40 1 1 W X AGND1 2 500 -900 200 L 40 40 1 1 W X AGND2 5 500 -1000 200 L 40 40 1 1 W X BUSY\ 25 500 -100 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 24 -500 800 200 R 40 40 1 1 I X D0 18 500 1200 200 L 40 40 1 1 O X D1 17 500 1100 200 L 40 40 1 1 O X D2 16 500 1000 200 L 40 40 1 1 O X D3 15 500 900 200 L 40 40 1 1 O X D4 13 500 800 200 L 40 40 1 1 O X D5 12 500 700 200 L 40 40 1 1 O X D6 11 500 600 200 L 40 40 1 1 O X D7 10 500 500 200 L 40 40 1 1 O X D8 9 500 400 200 L 40 40 1 1 O X D9 8 500 300 200 L 40 40 1 1 O X D10 7 500 200 200 L 40 40 1 1 O X D11 6 500 100 200 L 40 40 1 1 O X DGND 14 500 -1100 200 L 40 40 1 1 W X DGND@1 22 500 -1200 200 L 40 40 1 1 W X NC 19 -500 600 200 R 40 40 1 1 U X R/C\ 23 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7831U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7831U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7819 F0 "IC" -300 1325 50 H V L B F1 "ADS7831U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1300 P 2 1 0 0 -300 1300 300 1300 P 2 1 0 0 300 1300 300 -1300 X +VANA 20 500 -300 200 L 40 40 1 1 W X +VANA@1 28 500 -400 200 L 40 40 1 1 W X +VDIG 21 500 -600 200 L 40 40 1 1 W X +VDIG@1 27 500 -700 200 L 40 40 1 1 W X -VANA 26 500 -500 200 L 40 40 1 1 W X AGND1 2 500 -900 200 L 40 40 1 1 W X AGND2 5 500 -1000 200 L 40 40 1 1 W X BUSY\ 25 500 -100 200 L 40 40 1 1 O X CAP 4 -500 400 200 R 40 40 1 1 P X CS\ 24 -500 800 200 R 40 40 1 1 I X D0 18 500 1200 200 L 40 40 1 1 O X D1 17 500 1100 200 L 40 40 1 1 O X D2 16 500 1000 200 L 40 40 1 1 O X D3 15 500 900 200 L 40 40 1 1 O X D4 13 500 800 200 L 40 40 1 1 O X D5 12 500 700 200 L 40 40 1 1 O X D6 11 500 600 200 L 40 40 1 1 O X D7 10 500 500 200 L 40 40 1 1 O X D8 9 500 400 200 L 40 40 1 1 O X D9 8 500 300 200 L 40 40 1 1 O X D10 7 500 200 200 L 40 40 1 1 O X D11 6 500 100 200 L 40 40 1 1 O X DGND 14 500 -1100 200 L 40 40 1 1 W X DGND@1 22 500 -1200 200 L 40 40 1 1 W X NC 19 -500 600 200 R 40 40 1 1 U X R/C\ 23 -500 900 200 R 40 40 1 1 I X REF 3 -500 1000 200 R 40 40 1 1 B X VIN 1 -500 1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: ADS7833N # Package Name: PLCC68 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS7833N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS7833 F0 "IC" -400 2125 50 H V L B F1 "ADS7833N" -400 -2100 50 H V L B F2 "burr-brown-PLCC68" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -2000 500 -2000 P 2 1 0 0 500 -2000 500 2100 P 2 1 0 0 500 2100 -400 2100 P 2 1 0 0 -400 2100 -400 -2000 X AGND 67 700 -1700 200 L 40 40 1 1 W X AOUT 62 700 2000 200 L 40 40 1 1 O X ASH 38 -600 -1700 200 R 40 40 1 1 I X BUSY 40 700 1400 200 L 40 40 1 1 O X CLK 36 -600 -1900 200 R 40 40 1 1 I X CONV 37 -600 -1800 200 R 40 40 1 1 I X DCLOCK 41 700 1300 200 L 40 40 1 1 O X DGND 30 700 -1800 200 L 40 40 1 1 W X NC 7 -600 -100 200 R 40 40 1 1 U X NC@1 10 -600 -200 200 R 40 40 1 1 U X NC@2 13 -600 -300 200 R 40 40 1 1 U X NC@3 16 -600 -400 200 R 40 40 1 1 U X NC@4 19 -600 -500 200 R 40 40 1 1 U X NC@5 20 -600 -600 200 R 40 40 1 1 U X NC@6 21 -600 -700 200 R 40 40 1 1 U X NC@7 22 -600 -800 200 R 40 40 1 1 U X NC@8 23 700 -700 200 L 40 40 1 1 U X NC@9 24 700 -600 200 L 40 40 1 1 U X NC@10 25 700 -500 200 L 40 40 1 1 U X NC@11 26 700 -400 200 L 40 40 1 1 U X NC@12 32 700 -300 200 L 40 40 1 1 U X NC@13 42 700 -200 200 L 40 40 1 1 U X NC@14 43 700 -100 200 L 40 40 1 1 U X NC@15 44 700 0 200 L 40 40 1 1 U X NC@16 45 700 100 200 L 40 40 1 1 U X NC@17 46 700 200 200 L 40 40 1 1 U X NC@18 47 700 300 200 L 40 40 1 1 U X NC@19 48 700 400 200 L 40 40 1 1 U X NC@20 49 700 500 200 L 40 40 1 1 U X NC@21 50 700 600 200 L 40 40 1 1 U X NC@22 51 700 700 200 L 40 40 1 1 U X NC@23 54 700 800 200 L 40 40 1 1 U X NC@24 57 700 900 200 L 40 40 1 1 U X NC@25 60 700 1000 200 L 40 40 1 1 U X NC@26 61 700 1100 200 L 40 40 1 1 U X REFGND 65 700 -1900 200 L 40 40 1 1 W X REFIN 64 -600 -1000 200 R 40 40 1 1 I X REFOUT 63 700 -1000 200 L 40 40 1 1 O X SERIN 39 -600 -1600 200 R 40 40 1 1 I X SOUT1 35 700 1800 200 L 40 40 1 1 O X SOUT2 33 700 1700 200 L 40 40 1 1 O X SOUT3 34 700 1600 200 L 40 40 1 1 O X TP1 27 -600 -1200 200 R 40 40 1 1 P X TP2 28 -600 -1300 200 R 40 40 1 1 P X V1-1N 59 -600 2000 200 R 40 40 1 1 I X V1-1P 58 -600 1900 200 R 40 40 1 1 I X V1-2N 56 -600 1800 200 R 40 40 1 1 I X V1-2P 55 -600 1700 200 R 40 40 1 1 I X V1-3N 53 -600 1600 200 R 40 40 1 1 I X V1-3P 52 -600 1500 200 R 40 40 1 1 I X V2-1N 11 -600 1400 200 R 40 40 1 1 I X V2-1P 12 -600 1300 200 R 40 40 1 1 I X V2-2N 14 -600 1200 200 R 40 40 1 1 I X V2-2P 15 -600 1100 200 R 40 40 1 1 I X V2-3N 17 -600 1000 200 R 40 40 1 1 I X V2-3P 18 -600 900 200 R 40 40 1 1 I X V3-1N 8 -600 800 200 R 40 40 1 1 I X V3-1P 9 -600 700 200 R 40 40 1 1 I X V3-2N 5 -600 600 200 R 40 40 1 1 I X V3-2P 6 -600 500 200 R 40 40 1 1 I X V3-3N 3 -600 400 200 R 40 40 1 1 I X V3-3P 4 -600 300 200 R 40 40 1 1 I X V3-4N 1 -600 200 200 R 40 40 1 1 I X V3-4P 2 -600 100 200 R 40 40 1 1 I X VANA+ 68 700 -1200 200 L 40 40 1 1 W X VANA- 66 700 -1300 200 L 40 40 1 1 W X VDIG+ 29 700 -1400 200 L 40 40 1 1 W X VDIG- 31 700 -1500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ADS8344U # Package Name: SSOP20BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ADS8344U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ADS8344 F0 "IC" -400 650 50 H V L B F1 "ADS8344U" -400 -800 50 H V L B F2 "burr-brown-SSOP20BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 600 400 600 P 2 1 0 0 400 600 400 -700 P 2 1 0 0 400 -700 -400 -700 P 2 1 0 0 -400 -700 -400 600 X BUSY 16 500 -200 100 L 40 40 1 1 O X CH0 1 -500 500 100 R 40 40 1 1 I X CH1 2 -500 400 100 R 40 40 1 1 I X CH2 3 -500 300 100 R 40 40 1 1 I X CH3 4 -500 200 100 R 40 40 1 1 I X CH4 5 -500 100 100 R 40 40 1 1 I X CH5 6 -500 0 100 R 40 40 1 1 I X CH6 7 -500 -100 100 R 40 40 1 1 I X CH7 8 -500 -200 100 R 40 40 1 1 I X COM 9 -500 -600 100 R 40 40 1 1 I X CS\ 18 500 0 100 L 40 40 1 1 I X DCLK 19 500 100 100 L 40 40 1 1 I X DI 17 500 -100 100 L 40 40 1 1 I X DOUT 15 500 -300 100 L 40 40 1 1 O X GND 13 500 -500 100 L 40 40 1 1 W X GND@1 14 500 -600 100 L 40 40 1 1 W X SHDN\ 10 500 200 100 L 40 40 1 1 I X VCC 12 500 400 100 L 40 40 1 1 W X VCC@1 20 500 500 100 L 40 40 1 1 W X VREF 11 -500 -500 100 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: AFE1103E # Package Name: SSOP48DL # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF AFE1103E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: AFE1103 F0 "IC" -500 1825 50 H V L B F1 "AFE1103E" -500 -1900 50 H V L B F2 "burr-brown-SSOP48DL" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -1800 400 -1800 P 2 1 0 0 400 -1800 400 1800 P 2 1 0 0 400 1800 -500 1800 P 2 1 0 0 -500 1800 -500 -1800 X AGND 32 600 -1100 200 L 40 40 1 1 W X AGND@1 33 600 -1200 200 L 40 40 1 1 W X AGND@2 38 600 -1300 200 L 40 40 1 1 W X AGND@3 42 600 -1400 200 L 40 40 1 1 W X AVDD 27 600 -500 200 L 40 40 1 1 W X AVDD@1 37 600 -600 200 L 40 40 1 1 W X AVDD@2 40 600 -700 200 L 40 40 1 1 W X DGND 12 600 -1500 200 L 40 40 1 1 W X DGND@1 22 600 -1600 200 L 40 40 1 1 W X DVDD 13 600 -800 200 L 40 40 1 1 W X NC 43 -700 -1400 200 R 40 40 1 1 U X NC@1 44 -700 -1500 200 R 40 40 1 1 U X NC@2 45 -700 -1600 200 R 40 40 1 1 U X NC@3 46 -700 -1700 200 R 40 40 1 1 U X PGND 1 600 -1700 200 L 40 40 1 1 W X PLLIN 48 -700 200 200 R 40 40 1 1 I X PLLOUT 47 600 200 200 L 40 40 1 1 O X PVDD 2 600 -900 200 L 40 40 1 1 W X REFN 36 600 -300 200 L 40 40 1 1 O X REFP 34 600 -100 200 L 40 40 1 1 O X RXD0 6 600 1700 200 L 40 40 1 1 O X RXD1 7 600 1600 200 L 40 40 1 1 O X RXD2 8 600 1500 200 L 40 40 1 1 O X RXD3 9 600 1400 200 L 40 40 1 1 O X RXD4 10 600 1300 200 L 40 40 1 1 O X RXD5 11 600 1200 200 L 40 40 1 1 O X RXD6 14 600 1100 200 L 40 40 1 1 O X RXD7 15 600 1000 200 L 40 40 1 1 O X RXD8 16 600 900 200 L 40 40 1 1 O X RXD9 17 600 800 200 L 40 40 1 1 O X RXD10 18 600 700 200 L 40 40 1 1 O X RXD11 19 600 600 200 L 40 40 1 1 O X RXD12 20 600 500 200 L 40 40 1 1 O X RXD13 21 600 400 200 L 40 40 1 1 O X RXGAIN0 24 -700 -200 200 R 40 40 1 1 I X RXGAIN1 25 -700 -300 200 R 40 40 1 1 I X RXHYBN 28 -700 -700 200 R 40 40 1 1 I X RXHYBP 29 -700 -600 200 R 40 40 1 1 I X RXLN 39 -700 -500 200 R 40 40 1 1 I X RXLOOP 26 -700 -100 200 R 40 40 1 1 I X RXLP 31 -700 -400 200 R 40 40 1 1 I X RXSYNC 23 -700 0 200 R 40 40 1 1 I X TXCLK 3 -700 100 200 R 40 40 1 1 I X TXDN 4 -700 1600 200 R 40 40 1 1 I X TXDP 5 -700 1700 200 R 40 40 1 1 I X TXLN 30 600 0 200 L 40 40 1 1 O X TXLP 41 600 100 200 L 40 40 1 1 O X VCM 35 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: AFE1104E # Package Name: SSOP48DL # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF AFE1104E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: AFE1104 F0 "IC" -500 1925 50 H V L B F1 "AFE1104E" -500 -1800 50 H V L B F2 "burr-brown-SSOP48DL" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1700 -500 -1700 P 2 1 0 0 -500 -1700 -500 1900 P 2 1 0 0 -500 1900 400 1900 P 2 1 0 0 400 1900 400 -1700 X AGND 32 600 -1300 200 L 40 40 1 1 W X AGND@1 33 600 -1400 200 L 40 40 1 1 W X AGND@2 38 600 -1500 200 L 40 40 1 1 W X AGND@3 42 600 -1600 200 L 40 40 1 1 W X AV 27 600 -600 200 L 40 40 1 1 W X AV@1 37 600 -700 200 L 40 40 1 1 W X AV@2 40 600 -800 200 L 40 40 1 1 W X D0 6 600 1800 200 L 40 40 1 1 O X D1 7 600 1700 200 L 40 40 1 1 O X D2 8 600 1600 200 L 40 40 1 1 O X D3 9 600 1500 200 L 40 40 1 1 O X D4 10 600 1400 200 L 40 40 1 1 O X D5 11 600 1300 200 L 40 40 1 1 O X D6 14 600 1200 200 L 40 40 1 1 O X D7 15 600 1100 200 L 40 40 1 1 O X D8 16 600 1000 200 L 40 40 1 1 O X D9 17 600 900 200 L 40 40 1 1 O X D10 18 600 800 200 L 40 40 1 1 O X D11 19 600 700 200 L 40 40 1 1 O X D12 20 600 600 200 L 40 40 1 1 O X D13 21 600 500 200 L 40 40 1 1 O X DGND 4 600 -1100 200 L 40 40 1 1 W X DGND@1 12 600 -1200 200 L 40 40 1 1 W X DV 13 600 -500 200 L 40 40 1 1 W X LINEN 39 600 -100 200 L 40 40 1 1 O X LINEP 41 600 -200 200 L 40 40 1 1 O X NC 43 -700 -1300 200 R 40 40 1 1 U X NC@1 44 -700 -1400 200 R 40 40 1 1 U X NC@2 45 -700 -1500 200 R 40 40 1 1 U X NC@3 46 -700 -1600 200 R 40 40 1 1 U X PGND 1 600 -1000 200 L 40 40 1 1 W X PLLIN 48 -700 300 200 R 40 40 1 1 I X PLLOUT 47 600 300 200 L 40 40 1 1 O X PV 2 600 -400 200 L 40 40 1 1 W X REFN 36 600 0 200 L 40 40 1 1 O X REFP 34 600 200 200 L 40 40 1 1 O X RXCLK 22 -700 -700 200 R 40 40 1 1 I X RXGAIN0 24 -700 -100 200 R 40 40 1 1 I X RXGAIN1 25 -700 -200 200 R 40 40 1 1 I X RXHYBN 28 -700 -600 200 R 40 40 1 1 I X RXHYBP 29 -700 -500 200 R 40 40 1 1 I X RXLN 30 -700 -400 200 R 40 40 1 1 I X RXLOOP 26 -700 0 200 R 40 40 1 1 I X RXLP 31 -700 -300 200 R 40 40 1 1 I X RXSYNC 23 -700 100 200 R 40 40 1 1 I X TXCLK 3 -700 200 200 R 40 40 1 1 I X TXDAT 5 -700 1800 200 R 40 40 1 1 I X VCM 35 600 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: AFE1115E # Package Name: SSOP56DL # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF AFE1115E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: AFE1115 F0 "IC" -400 2025 50 H V L B F1 "AFE1115E" -400 -2200 50 H V L B F2 "burr-brown-SSOP56DL" 0 150 50 H I C C DRAW P 2 1 0 0 -400 2000 500 2000 P 2 1 0 0 500 2000 500 -2100 P 2 1 0 0 500 -2100 -400 -2100 P 2 1 0 0 -400 -2100 -400 2000 X AGND 36 700 -1500 200 L 40 40 1 1 W X AGND@1 37 700 -1600 200 L 40 40 1 1 W X AGND@2 42 700 -1700 200 L 40 40 1 1 W X AGND@3 46 700 -1800 200 L 40 40 1 1 W X AGND@4 48 700 -1900 200 L 40 40 1 1 W X AGND@5 49 700 -2000 200 L 40 40 1 1 O X AVDD 31 700 -800 200 L 40 40 1 1 W X AVDD@1 41 700 -900 200 L 40 40 1 1 W X AVDD@2 44 700 -1000 200 L 40 40 1 1 W X AVDD@3 50 700 -1100 200 L 40 40 1 1 W X DGND 56 700 -1400 200 L 40 40 1 1 W X DVDD 4 700 -600 200 L 40 40 1 1 W X DVDD@1 17 700 -700 200 L 40 40 1 1 W X GNDD 16 700 -1300 200 L 40 40 1 1 W X NC 5 -600 -1800 200 R 40 40 1 1 U X NC@1 6 -600 -1900 200 R 40 40 1 1 U X NC@2 26 -600 -2000 200 R 40 40 1 1 U X PLLIN 52 -600 400 200 R 40 40 1 1 I X PLLOUT 51 700 400 200 L 40 40 1 1 O X REFN 40 700 100 200 L 40 40 1 1 O X REFP 38 700 200 200 L 40 40 1 1 O X RXD0 10 700 1900 200 L 40 40 1 1 O X RXD1 11 700 1800 200 L 40 40 1 1 O X RXD2 12 700 1700 200 L 40 40 1 1 O X RXD3 13 700 1600 200 L 40 40 1 1 O X RXD4 14 700 1500 200 L 40 40 1 1 O X RXD5 15 700 1400 200 L 40 40 1 1 O X RXD6 18 700 1300 200 L 40 40 1 1 O X RXD7 19 700 1200 200 L 40 40 1 1 O X RXD8 20 700 1100 200 L 40 40 1 1 O X RXD9 21 700 1000 200 L 40 40 1 1 O X RXD10 22 700 900 200 L 40 40 1 1 O X RXD11 23 700 800 200 L 40 40 1 1 O X RXD12 24 700 700 200 L 40 40 1 1 O X RXD13 25 700 600 200 L 40 40 1 1 O X RXGAIN0 28 -600 -100 200 R 40 40 1 1 I X RXGAIN1 29 -600 -200 200 R 40 40 1 1 I X RXHYB+ 33 -600 -500 200 R 40 40 1 1 I X RXHYB- 32 -600 -600 200 R 40 40 1 1 I X RXLINE+ 35 -600 -300 200 R 40 40 1 1 I X RXLINE- 34 -600 -400 200 R 40 40 1 1 I X RXLOOP 30 -600 0 200 R 40 40 1 1 I X RXSYNC 27 -600 100 200 R 40 40 1 1 I X TXCLK 7 -600 300 200 R 40 40 1 1 I X TXDATA 9 -600 1900 200 R 40 40 1 1 I X TXLINE+ 45 700 0 200 L 40 40 1 1 O X TXLINE- 43 700 -100 200 L 40 40 1 1 O X TXSCLK 8 -600 200 200 R 40 40 1 1 I X VCCLK 3 700 -200 200 L 40 40 1 1 O X VCDAC 47 700 -400 200 L 40 40 1 1 O X VCDATA 54 -600 -800 200 R 40 40 1 1 I X VCINP 2 -600 -700 200 R 40 40 1 1 I X VCLATCH 53 -600 -1000 200 R 40 40 1 1 I X VCM 39 700 300 200 L 40 40 1 1 O X VCOUT 1 700 -300 200 L 40 40 1 1 O X VCSCLK 55 -600 -900 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: BUF634P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF BUF634P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: BUF634 F0 "IC" -200 325 50 H V L B F1 "BUF634P" -200 -400 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 300 -300 -200 -300 P 2 1 0 0 -200 -300 -200 300 P 2 1 0 0 -200 300 300 300 P 2 1 0 0 300 300 300 -300 X BW 1 -400 0 200 R 40 40 1 1 P X IN 3 -400 200 200 R 40 40 1 1 I X OUT 6 500 200 200 L 40 40 1 1 O X V+ 7 500 0 200 L 40 40 1 1 W X V- 4 500 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: BUF634T # Package Name: TO220-G5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF BUF634T IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: BUF634 F0 "IC" -200 325 50 H V L B F1 "BUF634T" -200 -400 50 H V L B F2 "burr-brown-TO220-G5" 0 150 50 H I C C DRAW P 2 1 0 0 300 -300 -200 -300 P 2 1 0 0 -200 -300 -200 300 P 2 1 0 0 -200 300 300 300 P 2 1 0 0 300 300 300 -300 X BW 1 -400 0 200 R 40 40 1 1 P X IN 2 -400 200 200 R 40 40 1 1 I X OUT 4 500 200 200 L 40 40 1 1 O X V+ 5 500 0 200 L 40 40 1 1 W X V- 3 500 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: BUF634U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF BUF634U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: BUF634 F0 "IC" -200 325 50 H V L B F1 "BUF634U" -200 -400 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 300 -300 -200 -300 P 2 1 0 0 -200 -300 -200 300 P 2 1 0 0 -200 300 300 300 P 2 1 0 0 300 300 300 -300 X BW 1 -400 0 200 R 40 40 1 1 P X IN 3 -400 200 200 R 40 40 1 1 I X OUT 6 500 200 200 L 40 40 1 1 O X V+ 7 500 0 200 L 40 40 1 1 W X V- 4 500 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DAC56P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC56P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC56 F0 "IC" -300 625 50 H V L B F1 "DAC56P" -300 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -600 X +VL 3 500 100 200 L 40 40 1 1 W X +VS 16 500 -100 200 L 40 40 1 1 W X -VL 8 500 0 200 L 40 40 1 1 W X -VS 1 500 -200 200 L 40 40 1 1 W X ACOM 12 500 -400 200 L 40 40 1 1 W X CLK 5 -500 200 200 R 40 40 1 1 I X DATA 7 -500 500 200 R 40 40 1 1 I X IOUT 13 500 300 200 L 40 40 1 1 O X LCOM 2 500 -500 200 L 40 40 1 1 W X LE 6 -500 300 200 R 40 40 1 1 I X MSBAD 14 -500 -300 200 R 40 40 1 1 P X NC 4 -500 -500 200 R 40 40 1 1 U X OUT 9 500 500 200 L 40 40 1 1 O X RF 10 -500 -100 200 R 40 40 1 1 P X SJ 11 -500 -200 200 R 40 40 1 1 P X TRIM 15 -500 0 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: DAC56U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC56U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC56 F0 "IC" -300 625 50 H V L B F1 "DAC56U" -300 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -600 X +VL 3 500 100 200 L 40 40 1 1 W X +VS 16 500 -100 200 L 40 40 1 1 W X -VL 8 500 0 200 L 40 40 1 1 W X -VS 1 500 -200 200 L 40 40 1 1 W X ACOM 12 500 -400 200 L 40 40 1 1 W X CLK 5 -500 200 200 R 40 40 1 1 I X DATA 7 -500 500 200 R 40 40 1 1 I X IOUT 13 500 300 200 L 40 40 1 1 O X LCOM 2 500 -500 200 L 40 40 1 1 W X LE 6 -500 300 200 R 40 40 1 1 I X MSBAD 14 -500 -300 200 R 40 40 1 1 P X NC 4 -500 -500 200 R 40 40 1 1 U X OUT 9 500 500 200 L 40 40 1 1 O X RF 10 -500 -100 200 R 40 40 1 1 P X SJ 11 -500 -200 200 R 40 40 1 1 P X TRIM 15 -500 0 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: DAC712P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC712P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC712 F0 "IC" -300 1025 50 H V L B F1 "DAC712P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -1300 400 -1300 P 2 1 0 0 400 -1300 400 1000 P 2 1 0 0 400 1000 -300 1000 P 2 1 0 0 -300 1000 -300 -1300 X +VCC 7 600 -800 200 L 40 40 1 1 W X -VCC 8 600 -900 200 L 40 40 1 1 W X A0 12 -500 -800 200 R 40 40 1 1 I X A1 11 -500 -900 200 R 40 40 1 1 I X ACOM 2 600 -1100 200 L 40 40 1 1 W X CLR\ 9 -500 -1100 200 R 40 40 1 1 I X D0 28 -500 900 200 R 40 40 1 1 I X D1 27 -500 800 200 R 40 40 1 1 I X D2 26 -500 700 200 R 40 40 1 1 I X D3 25 -500 600 200 R 40 40 1 1 I X D4 24 -500 500 200 R 40 40 1 1 I X D5 23 -500 400 200 R 40 40 1 1 I X D6 22 -500 300 200 R 40 40 1 1 I X D7 21 -500 200 200 R 40 40 1 1 I X D8 20 -500 100 200 R 40 40 1 1 I X D9 19 -500 0 200 R 40 40 1 1 I X D10 18 -500 -100 200 R 40 40 1 1 I X D11 17 -500 -200 200 R 40 40 1 1 I X D12 16 -500 -300 200 R 40 40 1 1 I X D13 15 -500 -400 200 R 40 40 1 1 I X D14 14 -500 -500 200 R 40 40 1 1 I X D15 13 -500 -600 200 R 40 40 1 1 I X DCOM 1 600 -1200 200 L 40 40 1 1 W X GA 6 600 400 200 L 40 40 1 1 P X OA 4 600 500 200 L 40 40 1 1 P X OUT 3 600 900 200 L 40 40 1 1 O X REF 5 600 700 200 L 40 40 1 1 O X WR\ 10 -500 -1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC712U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC712U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC712 F0 "IC" -300 1025 50 H V L B F1 "DAC712U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -1300 400 -1300 P 2 1 0 0 400 -1300 400 1000 P 2 1 0 0 400 1000 -300 1000 P 2 1 0 0 -300 1000 -300 -1300 X +VCC 7 600 -800 200 L 40 40 1 1 W X -VCC 8 600 -900 200 L 40 40 1 1 W X A0 12 -500 -800 200 R 40 40 1 1 I X A1 11 -500 -900 200 R 40 40 1 1 I X ACOM 2 600 -1100 200 L 40 40 1 1 W X CLR\ 9 -500 -1100 200 R 40 40 1 1 I X D0 28 -500 900 200 R 40 40 1 1 I X D1 27 -500 800 200 R 40 40 1 1 I X D2 26 -500 700 200 R 40 40 1 1 I X D3 25 -500 600 200 R 40 40 1 1 I X D4 24 -500 500 200 R 40 40 1 1 I X D5 23 -500 400 200 R 40 40 1 1 I X D6 22 -500 300 200 R 40 40 1 1 I X D7 21 -500 200 200 R 40 40 1 1 I X D8 20 -500 100 200 R 40 40 1 1 I X D9 19 -500 0 200 R 40 40 1 1 I X D10 18 -500 -100 200 R 40 40 1 1 I X D11 17 -500 -200 200 R 40 40 1 1 I X D12 16 -500 -300 200 R 40 40 1 1 I X D13 15 -500 -400 200 R 40 40 1 1 I X D14 14 -500 -500 200 R 40 40 1 1 I X D15 13 -500 -600 200 R 40 40 1 1 I X DCOM 1 600 -1200 200 L 40 40 1 1 W X GA 6 600 400 200 L 40 40 1 1 P X OA 4 600 500 200 L 40 40 1 1 P X OUT 3 600 900 200 L 40 40 1 1 O X REF 5 600 700 200 L 40 40 1 1 O X WR\ 10 -500 -1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC714P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC714P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC714 F0 "IC" -300 625 50 H V L B F1 "DAC714P" -300 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -600 X +VCC 7 500 -100 200 L 40 40 1 1 W X -VCC 15 500 -200 200 L 40 40 1 1 W X A0 2 -500 300 200 R 40 40 1 1 I X A1 3 -500 200 200 R 40 40 1 1 I X ACOM 8 500 -400 200 L 40 40 1 1 W X BPO 11 -500 -300 200 R 40 40 1 1 P X CLK\ 1 -500 0 200 R 40 40 1 1 I X CLR\ 16 -500 -100 200 R 40 40 1 1 I X DCOM 6 500 -500 200 L 40 40 1 1 W X FB2 10 500 200 200 L 40 40 1 1 O X GA 14 -500 -500 200 R 40 40 1 1 P X OA 13 -500 -400 200 R 40 40 1 1 P X OUT 9 500 500 200 L 40 40 1 1 O X REF 12 500 100 200 L 40 40 1 1 O X SDI 4 -500 500 200 R 40 40 1 1 I X SDO 5 500 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: DAC714U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC714U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC714 F0 "IC" -300 625 50 H V L B F1 "DAC714U" -300 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -600 X +VCC 7 500 -100 200 L 40 40 1 1 W X -VCC 15 500 -200 200 L 40 40 1 1 W X A0 2 -500 300 200 R 40 40 1 1 I X A1 3 -500 200 200 R 40 40 1 1 I X ACOM 8 500 -400 200 L 40 40 1 1 W X BPO 11 -500 -300 200 R 40 40 1 1 P X CLK\ 1 -500 0 200 R 40 40 1 1 I X CLR\ 16 -500 -100 200 R 40 40 1 1 I X DCOM 6 500 -500 200 L 40 40 1 1 W X FB2 10 500 200 200 L 40 40 1 1 O X GA 14 -500 -500 200 R 40 40 1 1 P X OA 13 -500 -400 200 R 40 40 1 1 P X OUT 9 500 500 200 L 40 40 1 1 O X REF 12 500 100 200 L 40 40 1 1 O X SDI 4 -500 500 200 R 40 40 1 1 I X SDO 5 500 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: DAC715P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC715P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC712 F0 "IC" -300 1025 50 H V L B F1 "DAC715P" -300 -1400 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -1300 400 -1300 P 2 1 0 0 400 -1300 400 1000 P 2 1 0 0 400 1000 -300 1000 P 2 1 0 0 -300 1000 -300 -1300 X +VCC 7 600 -800 200 L 40 40 1 1 W X -VCC 8 600 -900 200 L 40 40 1 1 W X A0 12 -500 -800 200 R 40 40 1 1 I X A1 11 -500 -900 200 R 40 40 1 1 I X ACOM 2 600 -1100 200 L 40 40 1 1 W X CLR\ 9 -500 -1100 200 R 40 40 1 1 I X D0 28 -500 900 200 R 40 40 1 1 I X D1 27 -500 800 200 R 40 40 1 1 I X D2 26 -500 700 200 R 40 40 1 1 I X D3 25 -500 600 200 R 40 40 1 1 I X D4 24 -500 500 200 R 40 40 1 1 I X D5 23 -500 400 200 R 40 40 1 1 I X D6 22 -500 300 200 R 40 40 1 1 I X D7 21 -500 200 200 R 40 40 1 1 I X D8 20 -500 100 200 R 40 40 1 1 I X D9 19 -500 0 200 R 40 40 1 1 I X D10 18 -500 -100 200 R 40 40 1 1 I X D11 17 -500 -200 200 R 40 40 1 1 I X D12 16 -500 -300 200 R 40 40 1 1 I X D13 15 -500 -400 200 R 40 40 1 1 I X D14 14 -500 -500 200 R 40 40 1 1 I X D15 13 -500 -600 200 R 40 40 1 1 I X DCOM 1 600 -1200 200 L 40 40 1 1 W X GA 6 600 400 200 L 40 40 1 1 P X OA 4 600 500 200 L 40 40 1 1 P X OUT 3 600 900 200 L 40 40 1 1 O X REF 5 600 700 200 L 40 40 1 1 O X WR\ 10 -500 -1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC715U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC715U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC712 F0 "IC" -300 1025 50 H V L B F1 "DAC715U" -300 -1400 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -1300 400 -1300 P 2 1 0 0 400 -1300 400 1000 P 2 1 0 0 400 1000 -300 1000 P 2 1 0 0 -300 1000 -300 -1300 X +VCC 7 600 -800 200 L 40 40 1 1 W X -VCC 8 600 -900 200 L 40 40 1 1 W X A0 12 -500 -800 200 R 40 40 1 1 I X A1 11 -500 -900 200 R 40 40 1 1 I X ACOM 2 600 -1100 200 L 40 40 1 1 W X CLR\ 9 -500 -1100 200 R 40 40 1 1 I X D0 28 -500 900 200 R 40 40 1 1 I X D1 27 -500 800 200 R 40 40 1 1 I X D2 26 -500 700 200 R 40 40 1 1 I X D3 25 -500 600 200 R 40 40 1 1 I X D4 24 -500 500 200 R 40 40 1 1 I X D5 23 -500 400 200 R 40 40 1 1 I X D6 22 -500 300 200 R 40 40 1 1 I X D7 21 -500 200 200 R 40 40 1 1 I X D8 20 -500 100 200 R 40 40 1 1 I X D9 19 -500 0 200 R 40 40 1 1 I X D10 18 -500 -100 200 R 40 40 1 1 I X D11 17 -500 -200 200 R 40 40 1 1 I X D12 16 -500 -300 200 R 40 40 1 1 I X D13 15 -500 -400 200 R 40 40 1 1 I X D14 14 -500 -500 200 R 40 40 1 1 I X D15 13 -500 -600 200 R 40 40 1 1 I X DCOM 1 600 -1200 200 L 40 40 1 1 W X GA 6 600 400 200 L 40 40 1 1 P X OA 4 600 500 200 L 40 40 1 1 P X OUT 3 600 900 200 L 40 40 1 1 O X REF 5 600 700 200 L 40 40 1 1 O X WR\ 10 -500 -1200 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC725P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC725P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC725 F0 "IC" -400 925 50 H V L B F1 "DAC725P" -400 -1100 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 300 -1000 P 2 1 0 0 300 -1000 300 900 P 2 1 0 0 300 900 -400 900 P 2 1 0 0 -400 900 -400 -1000 X +VCC 21 500 -400 200 L 40 40 1 1 W X -VCC 22 500 -300 200 L 40 40 1 1 W X A0\ 4 -600 -100 200 R 40 40 1 1 I X A1\ 5 -600 -200 200 R 40 40 1 1 I X A2\ 3 -600 -300 200 R 40 40 1 1 I X ACOMA 26 500 -700 200 L 40 40 1 1 W X ACOMB 16 500 -800 200 L 40 40 1 1 W X CLR\ 1 -600 -500 200 R 40 40 1 1 I X CS\A 23 -600 -800 200 R 40 40 1 1 I X CS\B 20 -600 -900 200 R 40 40 1 1 I X D0 13 -600 800 200 R 40 40 1 1 I X D1 12 -600 700 200 R 40 40 1 1 I X D2 11 -600 600 200 R 40 40 1 1 I X D3 10 -600 500 200 R 40 40 1 1 I X D4 9 -600 400 200 R 40 40 1 1 I X D5 8 -600 300 200 R 40 40 1 1 I X D6 7 -600 200 200 R 40 40 1 1 I X D7 6 -600 100 200 R 40 40 1 1 I X DCOM 14 500 -900 200 L 40 40 1 1 W X GAA 28 500 300 200 L 40 40 1 1 P X GAB 18 500 200 200 L 40 40 1 1 P X OUTA 25 500 800 200 L 40 40 1 1 O X OUTB 15 500 700 200 L 40 40 1 1 O X SJA 27 500 500 200 L 40 40 1 1 P X SJB 17 500 400 200 L 40 40 1 1 P X VDD 2 500 -500 200 L 40 40 1 1 W X WR\A 24 -600 -600 200 R 40 40 1 1 I X WR\B 19 -600 -700 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC813P # Package Name: DIL28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC813P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC813 F0 "IC" -400 925 50 H V L B F1 "DAC813P" -400 -1200 50 H V L B F2 "burr-brown-DIL28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1100 300 -1100 P 2 1 0 0 300 -1100 300 900 P 2 1 0 0 300 900 -400 900 P 2 1 0 0 -400 900 -400 -1100 X +VCC 8 500 -500 200 L 40 40 1 1 W X +VL 1 500 -700 200 L 40 40 1 1 W X -VCC 10 500 -600 200 L 40 40 1 1 W X ACOM 5 500 -900 200 L 40 40 1 1 W X BPO 4 500 500 200 L 40 40 1 1 P X D0 17 -600 800 200 R 40 40 1 1 I X D1 18 -600 700 200 R 40 40 1 1 I X D2 19 -600 600 200 R 40 40 1 1 I X D3 20 -600 500 200 R 40 40 1 1 I X D4 21 -600 400 200 R 40 40 1 1 I X D5 22 -600 300 200 R 40 40 1 1 I X D6 23 -600 200 200 R 40 40 1 1 I X D7 24 -600 100 200 R 40 40 1 1 I X D8 25 -600 0 200 R 40 40 1 1 I X D9 26 -600 -100 200 R 40 40 1 1 I X D10 27 -600 -200 200 R 40 40 1 1 I X D11 28 -600 -300 200 R 40 40 1 1 I X DCOM 16 500 -1000 200 L 40 40 1 1 W X LDAC\ 12 -600 -700 200 R 40 40 1 1 I X LLSB\ 15 -600 -1000 200 R 40 40 1 1 I X LMSB\ 14 -600 -900 200 R 40 40 1 1 I X OUT 9 500 800 200 L 40 40 1 1 O X RANGE 2 500 400 200 L 40 40 1 1 P X RANGE@1 3 500 300 200 L 40 40 1 1 P X REFIN 7 -600 -500 200 R 40 40 1 1 I X REFOUT 6 500 600 200 L 40 40 1 1 O X RESET\ 13 -600 -800 200 R 40 40 1 1 I X WR\ 11 -600 -600 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC813U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC813U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC813 F0 "IC" -400 925 50 H V L B F1 "DAC813U" -400 -1200 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1100 300 -1100 P 2 1 0 0 300 -1100 300 900 P 2 1 0 0 300 900 -400 900 P 2 1 0 0 -400 900 -400 -1100 X +VCC 8 500 -500 200 L 40 40 1 1 W X +VL 1 500 -700 200 L 40 40 1 1 W X -VCC 10 500 -600 200 L 40 40 1 1 W X ACOM 5 500 -900 200 L 40 40 1 1 W X BPO 4 500 500 200 L 40 40 1 1 P X D0 17 -600 800 200 R 40 40 1 1 I X D1 18 -600 700 200 R 40 40 1 1 I X D2 19 -600 600 200 R 40 40 1 1 I X D3 20 -600 500 200 R 40 40 1 1 I X D4 21 -600 400 200 R 40 40 1 1 I X D5 22 -600 300 200 R 40 40 1 1 I X D6 23 -600 200 200 R 40 40 1 1 I X D7 24 -600 100 200 R 40 40 1 1 I X D8 25 -600 0 200 R 40 40 1 1 I X D9 26 -600 -100 200 R 40 40 1 1 I X D10 27 -600 -200 200 R 40 40 1 1 I X D11 28 -600 -300 200 R 40 40 1 1 I X DCOM 16 500 -1000 200 L 40 40 1 1 W X LDAC\ 12 -600 -700 200 R 40 40 1 1 I X LLSB\ 15 -600 -1000 200 R 40 40 1 1 I X LMSB\ 14 -600 -900 200 R 40 40 1 1 I X OUT 9 500 800 200 L 40 40 1 1 O X RANGE 2 500 400 200 L 40 40 1 1 P X RANGE@1 3 500 300 200 L 40 40 1 1 P X REFIN 7 -600 -500 200 R 40 40 1 1 I X REFOUT 6 500 600 200 L 40 40 1 1 O X RESET\ 13 -600 -800 200 R 40 40 1 1 I X WR\ 11 -600 -600 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC4813P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC4813P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC4813 F0 "IC" -400 1125 50 H V L B F1 "DAC4813P" -400 -1100 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1000 300 -1000 P 2 1 0 0 300 -1000 300 1100 P 2 1 0 0 300 1100 -400 1100 P 2 1 0 0 -400 1100 -400 -1000 X +VCC 23 500 -500 200 L 40 40 1 1 W X -VCC 21 500 -600 200 L 40 40 1 1 W X ACOM 22 500 -800 200 L 40 40 1 1 W X DB0 12 -600 1000 200 R 40 40 1 1 I X DB1 11 -600 900 200 R 40 40 1 1 I X DB2 10 -600 800 200 R 40 40 1 1 I X DB3 9 -600 700 200 R 40 40 1 1 I X DB4 8 -600 600 200 R 40 40 1 1 I X DB5 7 -600 500 200 R 40 40 1 1 I X DB6 6 -600 400 200 R 40 40 1 1 I X DB7 5 -600 300 200 R 40 40 1 1 I X DB8 4 -600 200 200 R 40 40 1 1 I X DB9 3 -600 100 200 R 40 40 1 1 I X DB10 2 -600 0 200 R 40 40 1 1 I X DB11 1 -600 -100 200 R 40 40 1 1 I X DCOM 20 500 -900 200 L 40 40 1 1 W X EN1 15 -600 -300 200 R 40 40 1 1 I X EN2 16 -600 -400 200 R 40 40 1 1 I X EN3 17 -600 -500 200 R 40 40 1 1 I X EN4 18 -600 -600 200 R 40 40 1 1 I X LDAC\ 19 -600 -900 200 R 40 40 1 1 I X OUT1 27 500 1000 200 L 40 40 1 1 O X OUT2 26 500 900 200 L 40 40 1 1 O X OUT3 25 500 800 200 L 40 40 1 1 O X OUT4 24 500 700 200 L 40 40 1 1 O X REFOUT 28 500 500 200 L 40 40 1 1 O X RESET\ 13 -600 -700 200 R 40 40 1 1 I X WR\ 14 -600 -800 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC4814P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC4814P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC4814 F0 "IC" -500 825 50 H V L B F1 "DAC4814P" -500 -1000 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -900 500 -900 P 2 1 0 0 500 -900 500 800 P 2 1 0 0 500 800 -500 800 P 2 1 0 0 -500 800 -500 -900 X +VL 28 700 -400 200 L 40 40 1 1 W X +VS 15 700 -500 200 L 40 40 1 1 W X -VS 7 700 -600 200 L 40 40 1 1 W X AGND 12 700 -700 200 L 40 40 1 1 W X BPOA 6 -700 0 200 R 40 40 1 1 I X BPOB 5 -700 -100 200 R 40 40 1 1 I X BPOC 9 -700 -300 200 R 40 40 1 1 I X BPOD 8 -700 -200 200 R 40 40 1 1 I X CLK\ 19 -700 -700 200 R 40 40 1 1 I X CLR\ 24 -700 -500 200 R 40 40 1 1 I X CS\ 23 -700 -600 200 R 40 40 1 1 I X DATAIN 22 -700 700 200 R 40 40 1 1 I X DATAOUT 18 700 700 200 L 40 40 1 1 O X DGND 17 700 -800 200 L 40 40 1 1 W X INVIN 3 -700 200 200 R 40 40 1 1 I X INVOUT 11 700 0 200 L 40 40 1 1 O X LATCHA\ 27 -700 600 200 R 40 40 1 1 I X LATCHB\ 26 -700 500 200 R 40 40 1 1 I X LATCHC\ 21 -700 400 200 R 40 40 1 1 I X LATCHD\ 20 -700 300 200 R 40 40 1 1 I X MODE 25 -700 -400 200 R 40 40 1 1 I X NC 16 -700 -800 200 R 40 40 1 1 U X OUTA 2 700 600 200 L 40 40 1 1 O X OUTB 1 700 500 200 L 40 40 1 1 O X OUTC 14 700 400 200 L 40 40 1 1 O X OUTD 13 700 300 200 L 40 40 1 1 O X REFIN 10 -700 100 200 R 40 40 1 1 I X REFOUT 4 700 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: DAC4815PP # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC4815PP IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC4815 F0 "IC" -300 925 50 H V L B F1 "DAC4815PP" -300 -1200 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -1100 300 -1100 P 2 1 0 0 300 -1100 300 900 P 2 1 0 0 300 900 -300 900 P 2 1 0 0 -300 900 -300 -1100 X +VL 11 500 -700 200 L 40 40 1 1 W X +VS 8 500 -400 200 L 40 40 1 1 W X -VS 7 500 -500 200 L 40 40 1 1 W X A0 26 -500 -100 200 R 40 40 1 1 I X A1 27 -500 -200 200 R 40 40 1 1 I X A2 28 -500 -300 200 R 40 40 1 1 I X AGND 9 500 -900 200 L 40 40 1 1 W X BPO 6 -500 -600 200 R 40 40 1 1 I X CLR\ 14 -500 -700 200 R 40 40 1 1 I X CS\ 16 -500 -900 200 R 40 40 1 1 I X D0 18 -500 800 200 R 40 40 1 1 I X D1 19 -500 700 200 R 40 40 1 1 I X D2 20 -500 600 200 R 40 40 1 1 I X D3 21 -500 500 200 R 40 40 1 1 I X D4 22 -500 400 200 R 40 40 1 1 I X D5 23 -500 300 200 R 40 40 1 1 I X D6 24 -500 200 200 R 40 40 1 1 I X D7 25 -500 100 200 R 40 40 1 1 I X DGND 10 500 -1000 200 L 40 40 1 1 W X LE\ 17 -500 -800 200 R 40 40 1 1 I X OUTA 2 500 800 200 L 40 40 1 1 O X OUTB 1 500 700 200 L 40 40 1 1 O X OUTC 13 500 600 200 L 40 40 1 1 O X OUTD 12 500 500 200 L 40 40 1 1 O X REF+ 5 500 200 200 L 40 40 1 1 O X REF- 3 500 300 200 L 40 40 1 1 O X REFIN 4 -500 -500 200 R 40 40 1 1 I X WR\ 15 -500 -1000 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC7541AP # Package Name: DIL18 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF DAC7541AP IC 0 40 Y Y 2 L N # Gate Name: G # Symbol Name: DAC7541A F0 "IC" -300 750 50 H V L B F1 "DAC7541AP" -300 -900 50 H V L B F2 "burr-brown-DIL18" 0 150 50 H I C C DRAW P 2 1 0 0 -300 700 -300 -800 P 2 1 0 0 -300 -800 400 -800 P 2 1 0 0 400 700 400 -800 P 2 1 0 0 400 700 -300 700 X B1(MSB) 4 -400 500 100 R 40 40 1 1 I X B2 5 -400 400 100 R 40 40 1 1 I X B3 6 -400 300 100 R 40 40 1 1 I X B4 7 -400 200 100 R 40 40 1 1 I X B5 8 -400 100 100 R 40 40 1 1 I X B6 9 -400 0 100 R 40 40 1 1 I X B7 10 -400 -100 100 R 40 40 1 1 I X B8 11 -400 -200 100 R 40 40 1 1 I X B9 12 -400 -300 100 R 40 40 1 1 I X B10 13 -400 -400 100 R 40 40 1 1 I X B11 14 -400 -500 100 R 40 40 1 1 I X B12(LSB) 15 -400 -600 100 R 40 40 1 1 I X FEEDBACK 18 500 -700 100 L 40 40 1 1 P X IOUT1 1 500 100 100 L 40 40 1 1 O X IOUT2 2 500 -100 100 L 40 40 1 1 O X VREF 17 500 600 100 L 40 40 1 1 W # Gate Name: PWR # Symbol Name: PWRN T 1 50 -155 50 0 2 0 GND T 1 50 175 50 0 2 0 VCC X GND 3 0 -300 200 U 40 40 2 1 W X VCC 16 0 300 200 D 40 40 2 1 W ENDDRAW ENDDEF # # Dev Name: DAC7800P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC7800P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC7800 F0 "IC" -400 625 50 H V L B F1 "DAC7800P" -400 -800 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 300 -700 P 2 1 0 0 300 -700 300 600 P 2 1 0 0 300 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X AGNDA 1 500 -400 200 L 40 40 1 1 W X AGNDB 16 500 -500 200 L 40 40 1 1 W X CLK 5 -600 300 200 R 40 40 1 1 I X CLR\ 11 -600 100 200 R 40 40 1 1 I X CS\ 8 -600 200 200 R 40 40 1 1 I X DGND 9 500 -600 200 L 40 40 1 1 W X FBA 3 -600 -500 200 R 40 40 1 1 P X FBB 14 -600 -600 200 R 40 40 1 1 P X IN 7 -600 500 200 R 40 40 1 1 I X OUTA 2 500 500 200 L 40 40 1 1 O X OUTB 15 500 400 200 L 40 40 1 1 O X REFA 4 -600 -200 200 R 40 40 1 1 I X REFB 13 -600 -300 200 R 40 40 1 1 I X UPDA\ 6 -600 0 200 R 40 40 1 1 I X UPDB\ 10 -600 -100 200 R 40 40 1 1 I X VDD 12 500 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DAC7800U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC7800U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC7800 F0 "IC" -400 625 50 H V L B F1 "DAC7800U" -400 -800 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 300 -700 P 2 1 0 0 300 -700 300 600 P 2 1 0 0 300 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X AGNDA 1 500 -400 200 L 40 40 1 1 W X AGNDB 16 500 -500 200 L 40 40 1 1 W X CLK 5 -600 300 200 R 40 40 1 1 I X CLR\ 11 -600 100 200 R 40 40 1 1 I X CS\ 8 -600 200 200 R 40 40 1 1 I X DGND 9 500 -600 200 L 40 40 1 1 W X FBA 3 -600 -500 200 R 40 40 1 1 P X FBB 14 -600 -600 200 R 40 40 1 1 P X IN 7 -600 500 200 R 40 40 1 1 I X OUTA 2 500 500 200 L 40 40 1 1 O X OUTB 15 500 400 200 L 40 40 1 1 O X REFA 4 -600 -200 200 R 40 40 1 1 I X REFB 13 -600 -300 200 R 40 40 1 1 I X UPDA\ 6 -600 0 200 R 40 40 1 1 I X UPDB\ 10 -600 -100 200 R 40 40 1 1 I X VDD 12 500 -200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DAC7801P # Package Name: DIL24-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC7801P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC7801 F0 "IC" -400 1025 50 H V L B F1 "DAC7801P" -400 -1300 50 H V L B F2 "burr-brown-DIL24-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1000 P 2 1 0 0 300 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1200 X A0 15 -600 0 200 R 40 40 1 1 I X A1 16 -600 -100 200 R 40 40 1 1 I X AGNDA 1 500 -900 200 L 40 40 1 1 W X AGNDB 24 500 -1000 200 L 40 40 1 1 W X CLR\ 17 -600 -500 200 R 40 40 1 1 I X CS\ 5 -600 -400 200 R 40 40 1 1 I X DB0 6 -600 900 200 R 40 40 1 1 I X DB1 7 -600 800 200 R 40 40 1 1 I X DB2 8 -600 700 200 R 40 40 1 1 I X DB3 9 -600 600 200 R 40 40 1 1 I X DB4 10 -600 500 200 R 40 40 1 1 I X DB5 11 -600 400 200 R 40 40 1 1 I X DB6 13 -600 300 200 R 40 40 1 1 I X DB7 14 -600 200 200 R 40 40 1 1 I X DGND 12 500 -1100 200 L 40 40 1 1 W X FBA 3 -600 -1000 200 R 40 40 1 1 P X FBB 22 -600 -1100 200 R 40 40 1 1 P X OUTA 2 500 900 200 L 40 40 1 1 O X OUTB 23 500 800 200 L 40 40 1 1 O X REFA 4 -600 -700 200 R 40 40 1 1 I X REFB 21 -600 -800 200 R 40 40 1 1 I X UPD\ 19 -600 -600 200 R 40 40 1 1 I X VDD 20 500 -700 200 L 40 40 1 1 W X WR\ 18 -600 -300 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC7801U # Package Name: SO24L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC7801U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC7801 F0 "IC" -400 1025 50 H V L B F1 "DAC7801U" -400 -1300 50 H V L B F2 "burr-brown-SO24L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1000 P 2 1 0 0 300 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1200 X A0 15 -600 0 200 R 40 40 1 1 I X A1 16 -600 -100 200 R 40 40 1 1 I X AGNDA 1 500 -900 200 L 40 40 1 1 W X AGNDB 24 500 -1000 200 L 40 40 1 1 W X CLR\ 17 -600 -500 200 R 40 40 1 1 I X CS\ 5 -600 -400 200 R 40 40 1 1 I X DB0 6 -600 900 200 R 40 40 1 1 I X DB1 7 -600 800 200 R 40 40 1 1 I X DB2 8 -600 700 200 R 40 40 1 1 I X DB3 9 -600 600 200 R 40 40 1 1 I X DB4 10 -600 500 200 R 40 40 1 1 I X DB5 11 -600 400 200 R 40 40 1 1 I X DB6 13 -600 300 200 R 40 40 1 1 I X DB7 14 -600 200 200 R 40 40 1 1 I X DGND 12 500 -1100 200 L 40 40 1 1 W X FBA 3 -600 -1000 200 R 40 40 1 1 P X FBB 22 -600 -1100 200 R 40 40 1 1 P X OUTA 2 500 900 200 L 40 40 1 1 O X OUTB 23 500 800 200 L 40 40 1 1 O X REFA 4 -600 -700 200 R 40 40 1 1 I X REFB 21 -600 -800 200 R 40 40 1 1 I X UPD\ 19 -600 -600 200 R 40 40 1 1 I X VDD 20 500 -700 200 L 40 40 1 1 W X WR\ 18 -600 -300 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC7802P # Package Name: DIL24-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC7802P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC7802 F0 "IC" -400 1025 50 H V L B F1 "DAC7802P" -400 -1300 50 H V L B F2 "burr-brown-DIL24-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1000 P 2 1 0 0 300 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1200 X AGND 1 500 -1000 200 L 40 40 1 1 W X CSA\ 5 -600 -500 200 R 40 40 1 1 I X CSB\ 20 -600 -600 200 R 40 40 1 1 I X DB0 6 -600 900 200 R 40 40 1 1 I X DB1 7 -600 800 200 R 40 40 1 1 I X DB2 8 -600 700 200 R 40 40 1 1 I X DB3 9 -600 600 200 R 40 40 1 1 I X DB4 10 -600 500 200 R 40 40 1 1 I X DB5 11 -600 400 200 R 40 40 1 1 I X DB6 13 -600 300 200 R 40 40 1 1 I X DB7 14 -600 200 200 R 40 40 1 1 I X DB8 15 -600 100 200 R 40 40 1 1 I X DB9 16 -600 0 200 R 40 40 1 1 I X DB10 17 -600 -100 200 R 40 40 1 1 I X DB11 18 -600 -200 200 R 40 40 1 1 I X DGND 12 500 -1100 200 L 40 40 1 1 W X FBA 3 -600 -1000 200 R 40 40 1 1 P X FBB 23 -600 -1100 200 R 40 40 1 1 P X OUTA 2 500 900 200 L 40 40 1 1 O X OUTB 24 500 800 200 L 40 40 1 1 O X REFA 4 -600 -700 200 R 40 40 1 1 I X REFB 22 -600 -800 200 R 40 40 1 1 I X VDD 21 500 -800 200 L 40 40 1 1 W X WR\ 19 -600 -400 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DAC7802U # Package Name: SO24L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DAC7802U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DAC7802 F0 "IC" -400 1025 50 H V L B F1 "DAC7802U" -400 -1300 50 H V L B F2 "burr-brown-SO24L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1000 P 2 1 0 0 300 1000 -400 1000 P 2 1 0 0 -400 1000 -400 -1200 X AGND 1 500 -1000 200 L 40 40 1 1 W X CSA\ 5 -600 -500 200 R 40 40 1 1 I X CSB\ 20 -600 -600 200 R 40 40 1 1 I X DB0 6 -600 900 200 R 40 40 1 1 I X DB1 7 -600 800 200 R 40 40 1 1 I X DB2 8 -600 700 200 R 40 40 1 1 I X DB3 9 -600 600 200 R 40 40 1 1 I X DB4 10 -600 500 200 R 40 40 1 1 I X DB5 11 -600 400 200 R 40 40 1 1 I X DB6 13 -600 300 200 R 40 40 1 1 I X DB7 14 -600 200 200 R 40 40 1 1 I X DB8 15 -600 100 200 R 40 40 1 1 I X DB9 16 -600 0 200 R 40 40 1 1 I X DB10 17 -600 -100 200 R 40 40 1 1 I X DB11 18 -600 -200 200 R 40 40 1 1 I X DGND 12 500 -1100 200 L 40 40 1 1 W X FBA 3 -600 -1000 200 R 40 40 1 1 P X FBB 23 -600 -1100 200 R 40 40 1 1 P X OUTA 2 500 900 200 L 40 40 1 1 O X OUTB 24 500 800 200 L 40 40 1 1 O X REFA 4 -600 -700 200 R 40 40 1 1 I X REFB 22 -600 -800 200 R 40 40 1 1 I X VDD 21 500 -800 200 L 40 40 1 1 W X WR\ 19 -600 -400 200 R 40 40 1 1 I ENDDRAW ENDDEF # # Dev Name: DCP0105P # Package Name: DIL14/7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DCP0105P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DCP0124 F0 "IC" -300 325 50 H V L B F1 "DCP0105P" -300 -500 50 H V L B F2 "burr-brown-DIL14/7" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -400 400 -400 P 2 1 0 0 400 -400 400 300 P 2 1 0 0 400 300 -300 300 P 2 1 0 0 -300 300 -300 -400 X +VOUT 6 600 -100 200 L 40 40 1 1 W X 0V 2 -500 -300 200 R 40 40 1 1 W X 0V@1 5 600 -300 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X SYIN 14 -500 200 200 R 40 40 1 1 I X SYOUT 8 600 200 200 L 40 40 1 1 O X VS 1 -500 -200 200 R 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DCP0115P # Package Name: DIL14/7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DCP0115P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DCP0124D F0 "IC" -300 325 50 H V L B F1 "DCP0115P" -300 -500 50 H V L B F2 "burr-brown-DIL14/7" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -400 400 -400 P 2 1 0 0 400 -400 400 300 P 2 1 0 0 400 300 -300 300 P 2 1 0 0 -300 300 -300 -400 X +VOUT 6 600 0 200 L 40 40 1 1 W X -VOUT 7 600 -100 200 L 40 40 1 1 U X 0V 2 -500 -300 200 R 40 40 1 1 W X 0V@1 5 600 -300 200 L 40 40 1 1 W X SYIN 14 -500 200 200 R 40 40 1 1 I X SYOUT 8 600 200 200 L 40 40 1 1 O X VS 1 -500 -100 200 R 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DCP0124D # Package Name: DIL14/7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DCP0124D IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DCP0124D F0 "IC" -300 325 50 H V L B F1 "DCP0124D" -300 -500 50 H V L B F2 "burr-brown-DIL14/7" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -400 400 -400 P 2 1 0 0 400 -400 400 300 P 2 1 0 0 400 300 -300 300 P 2 1 0 0 -300 300 -300 -400 X +VOUT 6 600 0 200 L 40 40 1 1 W X -VOUT 7 600 -100 200 L 40 40 1 1 U X 0V 2 -500 -300 200 R 40 40 1 1 W X 0V@1 5 600 -300 200 L 40 40 1 1 W X SYIN 14 -500 200 200 R 40 40 1 1 I X SYOUT 8 600 200 200 L 40 40 1 1 O X VS 1 -500 -100 200 R 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DCP0124P # Package Name: DIL14/7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DCP0124P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DCP0124 F0 "IC" -300 325 50 H V L B F1 "DCP0124P" -300 -500 50 H V L B F2 "burr-brown-DIL14/7" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -400 400 -400 P 2 1 0 0 400 -400 400 300 P 2 1 0 0 400 300 -300 300 P 2 1 0 0 -300 300 -300 -400 X +VOUT 6 600 -100 200 L 40 40 1 1 W X 0V 2 -500 -300 200 R 40 40 1 1 W X 0V@1 5 600 -300 200 L 40 40 1 1 W X NC 7 -500 0 200 R 40 40 1 1 U X SYIN 14 -500 200 200 R 40 40 1 1 I X SYOUT 8 600 200 200 L 40 40 1 1 O X VS 1 -500 -200 200 R 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DDC101P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DDC101P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DDC101U F0 "IC" -400 725 50 H V L B F1 "DDC101P" -400 -1200 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1100 500 -1100 P 2 1 0 0 500 -1100 500 700 P 2 1 0 0 500 700 -400 700 P 2 1 0 0 -400 700 -400 -1100 X ANACOM 2 700 -800 200 L 40 40 1 1 W X ANACOM@1 4 700 -900 200 L 40 40 1 1 W X DATACLK 12 -600 100 200 R 40 40 1 1 I X DATAIN 13 -600 0 200 R 40 40 1 1 I X DGND 15 700 -1000 200 L 40 40 1 1 U X DIN 3 -600 600 200 R 40 40 1 1 I X DOUT 16 700 600 200 L 40 40 1 1 O X DTR\ 20 -600 -100 200 R 40 40 1 1 I X DVAL\ 17 700 400 200 L 40 40 1 1 O X FDS\ 10 -600 300 200 R 40 40 1 1 I X OVF+\ 19 700 300 200 L 40 40 1 1 O X OVF-\ 18 700 200 200 L 40 40 1 1 O X RD/SE\ 23 -600 -200 200 R 40 40 1 1 I X REF 27 -600 -500 200 R 40 40 1 1 I X REFBB 28 -600 -700 200 R 40 40 1 1 P X RESE\ 25 -600 -300 200 R 40 40 1 1 I X RESYS\ 9 -600 400 200 R 40 40 1 1 I X SETUP 24 -600 -600 200 R 40 40 1 1 I X SYSCLK 11 -600 200 200 R 40 40 1 1 I X TEST 26 -600 -400 200 R 40 40 1 1 I X VDD+ 14 700 -600 200 L 40 40 1 1 W X VS+ 5 700 -300 200 L 40 40 1 1 W X VS+@1 6 700 -400 200 L 40 40 1 1 W X VS- 1 700 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DDC101U # Package Name: SO24L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DDC101U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DDC101U F0 "IC" -400 725 50 H V L B F1 "DDC101U" -400 -1200 50 H V L B F2 "burr-brown-SO24L" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1100 500 -1100 P 2 1 0 0 500 -1100 500 700 P 2 1 0 0 500 700 -400 700 P 2 1 0 0 -400 700 -400 -1100 X ANACOM 2 700 -800 200 L 40 40 1 1 W X ANACOM@1 4 700 -900 200 L 40 40 1 1 W X DATACLK 10 -600 100 200 R 40 40 1 1 I X DATAIN 11 -600 0 200 R 40 40 1 1 I X DGND 13 700 -1000 200 L 40 40 1 1 U X DIN 3 -600 600 200 R 40 40 1 1 I X DOUT 14 700 600 200 L 40 40 1 1 O X DTR\ 18 -600 -100 200 R 40 40 1 1 I X DVAL\ 15 700 400 200 L 40 40 1 1 O X FDS\ 8 -600 300 200 R 40 40 1 1 I X OVF+\ 17 700 300 200 L 40 40 1 1 O X OVF-\ 16 700 200 200 L 40 40 1 1 O X RD/SE\ 19 -600 -200 200 R 40 40 1 1 I X REF 23 -600 -500 200 R 40 40 1 1 I X REFBB 24 -600 -700 200 R 40 40 1 1 P X RESE\ 21 -600 -300 200 R 40 40 1 1 I X RESYS\ 7 -600 400 200 R 40 40 1 1 I X SETUP 20 -600 -600 200 R 40 40 1 1 I X SYSCLK 9 -600 200 200 R 40 40 1 1 I X TEST 22 -600 -400 200 R 40 40 1 1 I X VDD+ 12 700 -600 200 L 40 40 1 1 W X VS+ 5 700 -300 200 L 40 40 1 1 W X VS+@1 6 700 -400 200 L 40 40 1 1 W X VS- 1 700 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DRV102-DDPAK/7 # Package Name: DD-7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DRV102-DDPAK/7 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DRV102-T0220/7 F0 "IC" 0 0 50 H V C C F1 "DRV102-DDPAK/7" 0 0 50 H V C C F2 "burr-brown-DD-7" 0 150 50 H I C C DRAW P 2 1 0 0 -700 -500 -700 500 P 2 1 0 0 -700 500 700 500 P 2 1 0 0 700 500 700 -500 P 2 1 0 0 700 -500 -700 -500 T 0 -390 235 70 0 1 0 DRV102 X DELAY 2 -300 -700 200 U 40 40 1 1 B X FLAG 7 500 700 200 D 40 40 1 1 O X GND 4 500 -700 200 U 40 40 1 1 w X IN 1 -900 0 200 R 40 40 1 1 I X OUT 6 900 0 200 L 40 40 1 1 O X PWM 3 100 -700 200 U 40 40 1 1 B X VS 5 100 700 200 D 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: DRV102-TO220/7 # Package Name: TO220-7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF DRV102-TO220/7 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: DRV102-T0220/7 F0 "IC" 0 0 50 H V C C F1 "DRV102-TO220/7" 0 0 50 H V C C F2 "burr-brown-TO220-7" 0 150 50 H I C C DRAW P 2 1 0 0 -700 -500 -700 500 P 2 1 0 0 -700 500 700 500 P 2 1 0 0 700 500 700 -500 P 2 1 0 0 700 -500 -700 -500 T 0 -390 235 70 0 1 0 DRV102 X DELAY 2 -300 -700 200 U 40 40 1 1 B X FLAG 7 500 700 200 D 40 40 1 1 O X GND 4 500 -700 200 U 40 40 1 1 w X IN 1 -900 0 200 R 40 40 1 1 I X OUT 6 900 0 200 L 40 40 1 1 O X PWM 3 100 -700 200 U 40 40 1 1 B X VS 5 100 700 200 D 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA103P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA103P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA103 F0 "IC" -400 725 50 H V L B F1 "INA103P" -400 -900 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 300 -300 350 P 2 1 0 0 -300 350 -300 450 P 2 1 0 0 -300 450 -300 500 P 2 1 0 0 -300 500 -100 400 P 2 1 0 0 -100 400 -300 300 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 0 375 0 400 P 2 1 0 0 0 400 0 425 P 2 1 0 0 0 425 100 425 P 2 1 0 0 100 425 100 400 P 2 1 0 0 100 400 100 375 P 2 1 0 0 100 375 0 375 P 2 1 0 0 -300 450 -350 450 P 2 1 0 0 300 425 300 400 P 2 1 0 0 300 400 300 375 P 2 1 0 0 300 375 200 375 P 2 1 0 0 200 375 200 400 P 2 1 0 0 200 400 200 425 P 2 1 0 0 200 425 300 425 P 2 1 0 0 200 -275 200 -300 P 2 1 0 0 200 -300 200 -325 P 2 1 0 0 200 -325 300 -325 P 2 1 0 0 300 -325 300 -300 P 2 1 0 0 300 -300 300 -275 P 2 1 0 0 300 -275 200 -275 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 -287 450 -262 450 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -275 462 -275 437 P 2 1 0 0 -400 -800 500 -800 P 2 1 0 0 500 -800 500 -300 P 2 1 0 0 500 -300 500 0 P 2 1 0 0 500 0 500 400 P 2 1 0 0 500 400 500 700 P 2 1 0 0 500 700 -400 700 P 2 1 0 0 -400 700 -400 600 P 2 1 0 0 -400 600 -400 500 P 2 1 0 0 -400 500 -400 300 P 2 1 0 0 -400 300 -400 200 P 2 1 0 0 -400 200 -400 0 P 2 1 0 0 -400 0 -400 -100 P 2 1 0 0 -400 -100 -400 -200 P 2 1 0 0 -400 -200 -400 -400 P 2 1 0 0 -400 -400 -400 -500 P 2 1 0 0 -400 -500 -400 -800 P 2 1 0 0 -300 -400 -300 -350 P 2 1 0 0 -300 -350 -300 -250 P 2 1 0 0 -300 -250 -300 -200 P 2 1 0 0 -300 -200 -100 -300 P 2 1 0 0 -100 -300 -300 -400 P 2 1 0 0 100 -325 100 -300 P 2 1 0 0 100 -300 100 -275 P 2 1 0 0 100 -275 0 -275 P 2 1 0 0 0 -275 0 -300 P 2 1 0 0 0 -300 0 -325 P 2 1 0 0 0 -325 100 -325 P 2 1 0 0 -200 -125 -200 -100 P 2 1 0 0 -200 -100 -200 -75 P 2 1 0 0 -200 -75 -100 -75 P 2 1 0 0 -100 -75 -100 -100 P 2 1 0 0 -100 -100 -100 -125 P 2 1 0 0 -100 -125 -200 -125 P 2 1 0 0 -300 -250 -350 -250 P 2 1 0 0 -300 -350 -350 -350 P 2 1 0 0 -287 -250 -262 -250 P 2 1 0 0 -287 -350 -262 -350 P 2 1 0 0 -275 -337 -275 -362 P 2 1 0 0 -350 450 -350 500 P 2 1 0 0 -350 500 -400 500 P 2 1 0 0 -350 350 -350 300 P 2 1 0 0 -350 300 -400 300 P 2 1 0 0 200 -100 200 -50 P 2 1 0 0 200 -50 200 50 P 2 1 0 0 200 50 200 100 P 2 1 0 0 200 100 400 0 P 2 1 0 0 400 0 200 -100 P 2 1 0 0 200 -50 150 -50 P 2 1 0 0 212 50 237 50 P 2 1 0 0 212 -50 237 -50 P 2 1 0 0 225 -37 225 -62 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 0 400 P 2 1 0 0 100 400 150 400 P 2 1 0 0 150 400 200 400 P 2 1 0 0 437 400 425 400 P 2 1 0 0 425 400 300 400 P 2 1 0 0 400 0 500 0 P 2 1 0 0 -300 200 -200 200 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 150 400 150 50 P 2 1 0 0 150 50 200 50 P 2 1 0 0 -350 -200 -350 -250 P 2 1 0 0 -100 -100 -50 -100 P 2 1 0 0 -50 -100 -50 -300 P 2 1 0 0 -50 -300 -100 -300 P 2 1 0 0 -50 -300 0 -300 P 2 1 0 0 100 -300 150 -300 P 2 1 0 0 150 -300 200 -300 P 2 1 0 0 -350 -350 -350 -400 P 2 1 0 0 -350 -400 -400 -400 P 2 1 0 0 -400 -200 -350 -200 P 2 1 0 0 150 -50 150 -300 P 2 1 0 0 300 -300 500 -300 P 2 1 0 0 -275 150 -300 150 P 2 1 0 0 -300 150 -325 150 P 2 1 0 0 -325 150 -325 50 P 2 1 0 0 -325 50 -300 50 P 2 1 0 0 -300 50 -275 50 P 2 1 0 0 -275 50 -275 150 P 2 1 0 0 -300 0 -300 50 P 2 1 0 0 -300 200 -300 150 P 2 1 0 0 -300 0 -400 0 P 2 1 0 0 -200 -100 -400 -100 P 2 1 0 0 425 400 500 400 P 2 1 0 0 -400 200 -300 200 P 2 1 0 0 -400 600 -50 600 P 2 1 0 0 -50 600 -50 400 P 2 1 0 0 -50 -300 -50 -500 P 2 1 0 0 -50 -500 -400 -500 C -50 400 12 1 1 0 N C 150 400 12 1 1 0 N C -50 -300 12 1 1 0 N C 150 -300 12 1 1 0 N C -300 200 12 1 1 0 N X +GD 5 -600 -500 200 R 40 40 1 1 P X +GS 2 -600 -200 200 R 40 40 1 1 I X +IN 1 -600 -400 200 R 40 40 1 1 I X +OFFS 3 -600 -600 200 R 40 40 1 1 P X +RG 6 -600 -100 200 R 40 40 1 1 P X -GD 12 -600 600 200 R 40 40 1 1 P X -GS 15 -600 300 200 R 40 40 1 1 I X -IN 16 -600 500 200 R 40 40 1 1 I X -OFFS 4 -600 -700 200 R 40 40 1 1 P X -RG 13 -600 200 200 R 40 40 1 1 P X G=100 14 -600 0 200 R 40 40 1 1 P X OUT 10 700 0 200 L 40 40 1 1 O X REF 7 700 -300 200 L 40 40 1 1 P X SENSE 11 700 400 200 L 40 40 1 1 I X V+ 9 700 -500 200 L 40 40 1 1 W X V- 8 700 -700 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA103U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA103U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA103 F0 "IC" -400 725 50 H V L B F1 "INA103U" -400 -900 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 300 -300 350 P 2 1 0 0 -300 350 -300 450 P 2 1 0 0 -300 450 -300 500 P 2 1 0 0 -300 500 -100 400 P 2 1 0 0 -100 400 -300 300 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 0 375 0 400 P 2 1 0 0 0 400 0 425 P 2 1 0 0 0 425 100 425 P 2 1 0 0 100 425 100 400 P 2 1 0 0 100 400 100 375 P 2 1 0 0 100 375 0 375 P 2 1 0 0 -300 450 -350 450 P 2 1 0 0 300 425 300 400 P 2 1 0 0 300 400 300 375 P 2 1 0 0 300 375 200 375 P 2 1 0 0 200 375 200 400 P 2 1 0 0 200 400 200 425 P 2 1 0 0 200 425 300 425 P 2 1 0 0 200 -275 200 -300 P 2 1 0 0 200 -300 200 -325 P 2 1 0 0 200 -325 300 -325 P 2 1 0 0 300 -325 300 -300 P 2 1 0 0 300 -300 300 -275 P 2 1 0 0 300 -275 200 -275 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 -287 450 -262 450 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -275 462 -275 437 P 2 1 0 0 -400 -800 500 -800 P 2 1 0 0 500 -800 500 -300 P 2 1 0 0 500 -300 500 0 P 2 1 0 0 500 0 500 400 P 2 1 0 0 500 400 500 700 P 2 1 0 0 500 700 -400 700 P 2 1 0 0 -400 700 -400 600 P 2 1 0 0 -400 600 -400 500 P 2 1 0 0 -400 500 -400 300 P 2 1 0 0 -400 300 -400 200 P 2 1 0 0 -400 200 -400 0 P 2 1 0 0 -400 0 -400 -100 P 2 1 0 0 -400 -100 -400 -200 P 2 1 0 0 -400 -200 -400 -400 P 2 1 0 0 -400 -400 -400 -500 P 2 1 0 0 -400 -500 -400 -800 P 2 1 0 0 -300 -400 -300 -350 P 2 1 0 0 -300 -350 -300 -250 P 2 1 0 0 -300 -250 -300 -200 P 2 1 0 0 -300 -200 -100 -300 P 2 1 0 0 -100 -300 -300 -400 P 2 1 0 0 100 -325 100 -300 P 2 1 0 0 100 -300 100 -275 P 2 1 0 0 100 -275 0 -275 P 2 1 0 0 0 -275 0 -300 P 2 1 0 0 0 -300 0 -325 P 2 1 0 0 0 -325 100 -325 P 2 1 0 0 -200 -125 -200 -100 P 2 1 0 0 -200 -100 -200 -75 P 2 1 0 0 -200 -75 -100 -75 P 2 1 0 0 -100 -75 -100 -100 P 2 1 0 0 -100 -100 -100 -125 P 2 1 0 0 -100 -125 -200 -125 P 2 1 0 0 -300 -250 -350 -250 P 2 1 0 0 -300 -350 -350 -350 P 2 1 0 0 -287 -250 -262 -250 P 2 1 0 0 -287 -350 -262 -350 P 2 1 0 0 -275 -337 -275 -362 P 2 1 0 0 -350 450 -350 500 P 2 1 0 0 -350 500 -400 500 P 2 1 0 0 -350 350 -350 300 P 2 1 0 0 -350 300 -400 300 P 2 1 0 0 200 -100 200 -50 P 2 1 0 0 200 -50 200 50 P 2 1 0 0 200 50 200 100 P 2 1 0 0 200 100 400 0 P 2 1 0 0 400 0 200 -100 P 2 1 0 0 200 -50 150 -50 P 2 1 0 0 212 50 237 50 P 2 1 0 0 212 -50 237 -50 P 2 1 0 0 225 -37 225 -62 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 0 400 P 2 1 0 0 100 400 150 400 P 2 1 0 0 150 400 200 400 P 2 1 0 0 437 400 425 400 P 2 1 0 0 425 400 300 400 P 2 1 0 0 400 0 500 0 P 2 1 0 0 -300 200 -200 200 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 150 400 150 50 P 2 1 0 0 150 50 200 50 P 2 1 0 0 -350 -200 -350 -250 P 2 1 0 0 -100 -100 -50 -100 P 2 1 0 0 -50 -100 -50 -300 P 2 1 0 0 -50 -300 -100 -300 P 2 1 0 0 -50 -300 0 -300 P 2 1 0 0 100 -300 150 -300 P 2 1 0 0 150 -300 200 -300 P 2 1 0 0 -350 -350 -350 -400 P 2 1 0 0 -350 -400 -400 -400 P 2 1 0 0 -400 -200 -350 -200 P 2 1 0 0 150 -50 150 -300 P 2 1 0 0 300 -300 500 -300 P 2 1 0 0 -275 150 -300 150 P 2 1 0 0 -300 150 -325 150 P 2 1 0 0 -325 150 -325 50 P 2 1 0 0 -325 50 -300 50 P 2 1 0 0 -300 50 -275 50 P 2 1 0 0 -275 50 -275 150 P 2 1 0 0 -300 0 -300 50 P 2 1 0 0 -300 200 -300 150 P 2 1 0 0 -300 0 -400 0 P 2 1 0 0 -200 -100 -400 -100 P 2 1 0 0 425 400 500 400 P 2 1 0 0 -400 200 -300 200 P 2 1 0 0 -400 600 -50 600 P 2 1 0 0 -50 600 -50 400 P 2 1 0 0 -50 -300 -50 -500 P 2 1 0 0 -50 -500 -400 -500 C -50 400 12 1 1 0 N C 150 400 12 1 1 0 N C -50 -300 12 1 1 0 N C 150 -300 12 1 1 0 N C -300 200 12 1 1 0 N X +GD 5 -600 -500 200 R 40 40 1 1 P X +GS 2 -600 -200 200 R 40 40 1 1 I X +IN 1 -600 -400 200 R 40 40 1 1 I X +OFFS 3 -600 -600 200 R 40 40 1 1 P X +RG 6 -600 -100 200 R 40 40 1 1 P X -GD 12 -600 600 200 R 40 40 1 1 P X -GS 15 -600 300 200 R 40 40 1 1 I X -IN 16 -600 500 200 R 40 40 1 1 I X -OFFS 4 -600 -700 200 R 40 40 1 1 P X -RG 13 -600 200 200 R 40 40 1 1 P X G=100 14 -600 0 200 R 40 40 1 1 P X OUT 10 700 0 200 L 40 40 1 1 O X REF 7 700 -300 200 L 40 40 1 1 P X SENSE 11 700 400 200 L 40 40 1 1 I X V+ 9 700 -500 200 L 40 40 1 1 W X V- 8 700 -700 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA105M # Package Name: TO99 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA105M IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA105M" -500 -500 50 H V L B F2 "burr-brown-TO99" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA105P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA105P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA105P" -500 -500 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA105U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA105U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA105U" -500 -500 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA110KP # Package Name: DIL16 # Dev Tech: K # Dev Prefix: IC # Gate count = 2 # DEF INA110KP IC 0 40 Y Y 2 L N # Gate Name: G$1 # Symbol Name: INA110 F0 "IC" -500 550 50 H V L B F1 "INA110KP" -500 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -600 500 -600 P 2 1 0 0 500 -600 500 500 P 2 1 0 0 500 500 -500 500 P 2 1 0 0 -500 500 -500 -600 X *10 13 -600 300 100 R 40 40 1 1 P X *100 12 -600 200 100 R 40 40 1 1 P X *200 16 -600 100 100 R 40 40 1 1 P X *500 11 -600 0 100 R 40 40 1 1 P X +IN 2 -600 -200 100 R 40 40 1 1 I X -IN 1 -600 400 100 R 40 40 1 1 I X OUTPUT 9 600 200 100 L 40 40 1 1 O X O_IN@1 4 -600 -400 100 R 40 40 1 1 P X O_IN@2 5 -600 -500 100 R 40 40 1 1 P X O_OUT@1 15 600 -400 100 L 40 40 1 1 P X O_OUT@2 14 600 -500 100 L 40 40 1 1 P X REF 6 600 0 100 L 40 40 1 1 I X RG 3 -600 -100 100 R 40 40 1 1 P X SENSE 10 600 400 100 L 40 40 1 1 I # Gate Name: P # Symbol Name: +-VCC X +VCC 8 0 500 100 D 40 40 2 1 W X -VCC 7 0 -600 100 U 40 40 2 1 W ENDDRAW ENDDEF # # Dev Name: INA110KU # Package Name: SO16-1 # Dev Tech: K # Dev Prefix: IC # Gate count = 2 # DEF INA110KU IC 0 40 Y Y 2 L N # Gate Name: G$1 # Symbol Name: INA110 F0 "IC" -500 550 50 H V L B F1 "INA110KU" -500 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -600 500 -600 P 2 1 0 0 500 -600 500 500 P 2 1 0 0 500 500 -500 500 P 2 1 0 0 -500 500 -500 -600 X *10 13 -600 300 100 R 40 40 1 1 P X *100 12 -600 200 100 R 40 40 1 1 P X *200 16 -600 100 100 R 40 40 1 1 P X *500 11 -600 0 100 R 40 40 1 1 P X +IN 2 -600 -200 100 R 40 40 1 1 I X -IN 1 -600 400 100 R 40 40 1 1 I X OUTPUT 9 600 200 100 L 40 40 1 1 O X O_IN@1 4 -600 -400 100 R 40 40 1 1 P X O_IN@2 5 -600 -500 100 R 40 40 1 1 P X O_OUT@1 15 600 -400 100 L 40 40 1 1 P X O_OUT@2 14 600 -500 100 L 40 40 1 1 P X REF 6 600 0 100 L 40 40 1 1 I X RG 3 -600 -100 100 R 40 40 1 1 P X SENSE 10 600 400 100 L 40 40 1 1 I # Gate Name: P # Symbol Name: +-VCC X +VCC 8 0 500 100 D 40 40 2 1 W X -VCC 7 0 -600 100 U 40 40 2 1 W ENDDRAW ENDDEF # # Dev Name: INA111P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA111P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA114 F0 "IC" -500 625 50 H V L B F1 "INA111P" -500 -600 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -400 300 -400 350 P 2 1 0 0 -400 350 -400 450 P 2 1 0 0 -400 450 -400 500 P 2 1 0 0 -400 500 -200 400 P 2 1 0 0 -200 400 -400 300 P 2 1 0 0 -200 175 -200 200 P 2 1 0 0 -200 200 -200 225 P 2 1 0 0 -200 225 -300 225 P 2 1 0 0 -300 225 -300 200 P 2 1 0 0 -300 200 -300 175 P 2 1 0 0 -300 175 -200 175 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 0 425 P 2 1 0 0 0 425 0 400 P 2 1 0 0 0 400 0 375 P 2 1 0 0 0 375 -100 375 P 2 1 0 0 -400 450 -450 450 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 100 -75 100 -100 P 2 1 0 0 100 -100 100 -125 P 2 1 0 0 100 -125 200 -125 P 2 1 0 0 200 -125 200 -100 P 2 1 0 0 200 -100 200 -75 P 2 1 0 0 200 -75 100 -75 P 2 1 0 0 -400 350 -450 350 P 2 1 0 0 -387 450 -362 450 P 2 1 0 0 -387 350 -362 350 P 2 1 0 0 -375 462 -375 437 P 2 1 0 0 -500 -500 400 -500 P 2 1 0 0 400 -500 400 -100 P 2 1 0 0 400 -100 400 200 P 2 1 0 0 400 200 400 600 P 2 1 0 0 400 600 -500 600 P 2 1 0 0 -500 600 -500 500 P 2 1 0 0 -500 500 -500 300 P 2 1 0 0 -500 300 -500 0 P 2 1 0 0 -500 0 -500 -200 P 2 1 0 0 -500 -200 -500 -500 P 2 1 0 0 -400 -200 -400 -150 P 2 1 0 0 -400 -150 -400 -50 P 2 1 0 0 -400 -50 -400 0 P 2 1 0 0 -400 0 -200 -100 P 2 1 0 0 -200 -100 -400 -200 P 2 1 0 0 0 -125 0 -100 P 2 1 0 0 0 -100 0 -75 P 2 1 0 0 0 -75 -100 -75 P 2 1 0 0 -100 -75 -100 -100 P 2 1 0 0 -100 -100 -100 -125 P 2 1 0 0 -100 -125 0 -125 P 2 1 0 0 -300 75 -300 100 P 2 1 0 0 -300 100 -300 125 P 2 1 0 0 -300 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -300 75 P 2 1 0 0 -400 -50 -450 -50 P 2 1 0 0 -400 -150 -450 -150 P 2 1 0 0 -387 -50 -362 -50 P 2 1 0 0 -387 -150 -362 -150 P 2 1 0 0 -375 -137 -375 -162 P 2 1 0 0 -450 450 -450 500 P 2 1 0 0 -450 500 -500 500 P 2 1 0 0 -450 350 -450 300 P 2 1 0 0 -450 300 -500 300 P 2 1 0 0 100 100 100 150 P 2 1 0 0 100 150 100 250 P 2 1 0 0 100 250 100 300 P 2 1 0 0 100 300 300 200 P 2 1 0 0 300 200 100 100 P 2 1 0 0 100 150 50 150 P 2 1 0 0 112 250 137 250 P 2 1 0 0 112 150 137 150 P 2 1 0 0 125 162 125 137 P 2 1 0 0 -200 400 -150 400 P 2 1 0 0 -150 400 -100 400 P 2 1 0 0 0 400 50 400 P 2 1 0 0 50 400 100 400 P 2 1 0 0 300 200 337 200 P 2 1 0 0 337 200 337 400 P 2 1 0 0 337 400 200 400 P 2 1 0 0 337 200 400 200 P 2 1 0 0 -450 300 -450 200 P 2 1 0 0 -450 200 -300 200 P 2 1 0 0 -150 400 -150 200 P 2 1 0 0 -150 200 -200 200 P 2 1 0 0 50 400 50 250 P 2 1 0 0 50 250 100 250 P 2 1 0 0 -300 100 -450 100 P 2 1 0 0 -450 100 -450 0 P 2 1 0 0 -450 0 -450 -50 P 2 1 0 0 -200 100 -150 100 P 2 1 0 0 -150 100 -150 -100 P 2 1 0 0 -150 -100 -200 -100 P 2 1 0 0 -150 -100 -100 -100 P 2 1 0 0 0 -100 50 -100 P 2 1 0 0 50 -100 100 -100 P 2 1 0 0 -450 -150 -450 -200 P 2 1 0 0 -450 -200 -500 -200 P 2 1 0 0 -500 0 -450 0 P 2 1 0 0 50 150 50 -100 P 2 1 0 0 200 -100 400 -100 C -450 300 12 1 1 0 N C -150 400 12 1 1 0 N C 50 400 12 1 1 0 N C 337 200 12 1 1 0 N C -450 0 12 1 1 0 N C -150 -100 12 1 1 0 N C 50 -100 12 1 1 0 N X +IN 3 -700 -200 200 R 40 40 1 1 I X -IN 2 -700 500 200 R 40 40 1 1 I X OUT 6 600 200 200 L 40 40 1 1 O X REF 5 600 -100 200 L 40 40 1 1 P X RG 1 -700 300 200 R 40 40 1 1 P X RG@1 8 -700 0 200 R 40 40 1 1 P X V+ 7 600 -200 200 L 40 40 1 1 W X V- 4 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA111U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA111U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA114U F0 "IC" -400 925 50 H V L B F1 "INA111U" -400 -900 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 600 -300 650 P 2 1 0 0 -300 650 -300 750 P 2 1 0 0 -300 750 -300 800 P 2 1 0 0 -300 800 -100 700 P 2 1 0 0 -100 700 -300 600 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 0 675 0 700 P 2 1 0 0 0 700 0 725 P 2 1 0 0 0 725 100 725 P 2 1 0 0 100 725 100 700 P 2 1 0 0 100 700 100 675 P 2 1 0 0 100 675 0 675 P 2 1 0 0 -300 750 -350 750 P 2 1 0 0 300 725 300 700 P 2 1 0 0 300 700 300 675 P 2 1 0 0 300 675 200 675 P 2 1 0 0 200 675 200 700 P 2 1 0 0 200 700 200 725 P 2 1 0 0 200 725 300 725 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 300 175 P 2 1 0 0 300 175 300 200 P 2 1 0 0 300 200 300 225 P 2 1 0 0 300 225 200 225 P 2 1 0 0 -300 650 -350 650 P 2 1 0 0 -287 750 -262 750 P 2 1 0 0 -287 650 -262 650 P 2 1 0 0 -275 762 -275 737 P 2 1 0 0 -400 -800 500 -800 P 2 1 0 0 500 -800 500 200 P 2 1 0 0 500 200 500 500 P 2 1 0 0 500 500 500 700 P 2 1 0 0 500 700 500 900 P 2 1 0 0 500 900 -400 900 P 2 1 0 0 -400 900 -400 800 P 2 1 0 0 -400 800 -400 600 P 2 1 0 0 -400 600 -400 300 P 2 1 0 0 -400 300 -400 100 P 2 1 0 0 -400 100 -400 -800 P 2 1 0 0 -300 100 -300 150 P 2 1 0 0 -300 150 -300 250 P 2 1 0 0 -300 250 -300 300 P 2 1 0 0 -300 300 -100 200 P 2 1 0 0 -100 200 -300 100 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 0 225 P 2 1 0 0 0 225 0 200 P 2 1 0 0 0 200 0 175 P 2 1 0 0 0 175 100 175 P 2 1 0 0 -200 375 -200 400 P 2 1 0 0 -200 400 -200 425 P 2 1 0 0 -200 425 -100 425 P 2 1 0 0 -100 425 -100 400 P 2 1 0 0 -100 400 -100 375 P 2 1 0 0 -100 375 -200 375 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -300 150 -350 150 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -287 150 -262 150 P 2 1 0 0 -275 162 -275 137 P 2 1 0 0 -350 750 -350 800 P 2 1 0 0 -350 800 -400 800 P 2 1 0 0 -350 650 -350 600 P 2 1 0 0 -350 600 -400 600 P 2 1 0 0 200 400 200 450 P 2 1 0 0 200 450 200 550 P 2 1 0 0 200 550 200 600 P 2 1 0 0 200 600 400 500 P 2 1 0 0 400 500 200 400 P 2 1 0 0 200 450 150 450 P 2 1 0 0 212 550 237 550 P 2 1 0 0 212 450 237 450 P 2 1 0 0 225 462 225 437 P 2 1 0 0 -100 700 -50 700 P 2 1 0 0 -50 700 0 700 P 2 1 0 0 100 700 150 700 P 2 1 0 0 150 700 200 700 P 2 1 0 0 400 500 500 500 P 2 1 0 0 -350 600 -350 500 P 2 1 0 0 -350 500 -200 500 P 2 1 0 0 -50 700 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 150 700 150 550 P 2 1 0 0 150 550 200 550 P 2 1 0 0 -200 400 -350 400 P 2 1 0 0 -350 400 -350 300 P 2 1 0 0 -350 300 -350 250 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 0 200 P 2 1 0 0 100 200 150 200 P 2 1 0 0 150 200 200 200 P 2 1 0 0 -350 150 -350 100 P 2 1 0 0 -350 100 -400 100 P 2 1 0 0 -400 300 -350 300 P 2 1 0 0 150 450 150 200 P 2 1 0 0 300 200 500 200 P 2 1 0 0 500 700 300 700 C -350 600 12 1 1 0 N C -50 700 12 1 1 0 N C 150 700 12 1 1 0 N C -350 300 12 1 1 0 N C -50 200 12 1 1 0 N C 150 200 12 1 1 0 N T 0 -250 -200 60 0 1 0 NC T 0 -250 -300 60 0 1 0 NC T 0 -250 -400 60 0 1 0 NC T 0 -250 -500 60 0 1 0 NC T 0 -250 -600 60 0 1 0 NC T 0 -250 -700 60 0 1 0 NC X +IN 5 -500 100 100 R 40 40 1 1 I X -IN 4 -500 800 100 R 40 40 1 1 I X FB 12 600 700 100 L 40 40 1 1 P X NC 1 -500 -100 100 R 40 40 1 1 U X NC@1 3 -500 -200 100 R 40 40 1 1 U X NC@2 6 -500 -300 100 R 40 40 1 1 U X NC@3 8 -500 -400 100 R 40 40 1 1 U X NC@4 9 -500 -500 100 R 40 40 1 1 U X NC@5 14 -500 -600 100 R 40 40 1 1 U X NC@6 16 -500 -700 100 R 40 40 1 1 U X OUT 11 600 500 100 L 40 40 1 1 O X REF 10 600 200 100 L 40 40 1 1 P X RG 2 -500 600 100 R 40 40 1 1 P X RG@1 15 -500 300 100 R 40 40 1 1 P X V+ 13 600 -500 100 L 40 40 1 1 W X V- 7 600 -700 100 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA114P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA114P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA114 F0 "IC" -500 625 50 H V L B F1 "INA114P" -500 -600 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -400 300 -400 350 P 2 1 0 0 -400 350 -400 450 P 2 1 0 0 -400 450 -400 500 P 2 1 0 0 -400 500 -200 400 P 2 1 0 0 -200 400 -400 300 P 2 1 0 0 -200 175 -200 200 P 2 1 0 0 -200 200 -200 225 P 2 1 0 0 -200 225 -300 225 P 2 1 0 0 -300 225 -300 200 P 2 1 0 0 -300 200 -300 175 P 2 1 0 0 -300 175 -200 175 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 0 425 P 2 1 0 0 0 425 0 400 P 2 1 0 0 0 400 0 375 P 2 1 0 0 0 375 -100 375 P 2 1 0 0 -400 450 -450 450 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 100 -75 100 -100 P 2 1 0 0 100 -100 100 -125 P 2 1 0 0 100 -125 200 -125 P 2 1 0 0 200 -125 200 -100 P 2 1 0 0 200 -100 200 -75 P 2 1 0 0 200 -75 100 -75 P 2 1 0 0 -400 350 -450 350 P 2 1 0 0 -387 450 -362 450 P 2 1 0 0 -387 350 -362 350 P 2 1 0 0 -375 462 -375 437 P 2 1 0 0 -500 -500 400 -500 P 2 1 0 0 400 -500 400 -100 P 2 1 0 0 400 -100 400 200 P 2 1 0 0 400 200 400 600 P 2 1 0 0 400 600 -500 600 P 2 1 0 0 -500 600 -500 500 P 2 1 0 0 -500 500 -500 300 P 2 1 0 0 -500 300 -500 0 P 2 1 0 0 -500 0 -500 -200 P 2 1 0 0 -500 -200 -500 -500 P 2 1 0 0 -400 -200 -400 -150 P 2 1 0 0 -400 -150 -400 -50 P 2 1 0 0 -400 -50 -400 0 P 2 1 0 0 -400 0 -200 -100 P 2 1 0 0 -200 -100 -400 -200 P 2 1 0 0 0 -125 0 -100 P 2 1 0 0 0 -100 0 -75 P 2 1 0 0 0 -75 -100 -75 P 2 1 0 0 -100 -75 -100 -100 P 2 1 0 0 -100 -100 -100 -125 P 2 1 0 0 -100 -125 0 -125 P 2 1 0 0 -300 75 -300 100 P 2 1 0 0 -300 100 -300 125 P 2 1 0 0 -300 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -300 75 P 2 1 0 0 -400 -50 -450 -50 P 2 1 0 0 -400 -150 -450 -150 P 2 1 0 0 -387 -50 -362 -50 P 2 1 0 0 -387 -150 -362 -150 P 2 1 0 0 -375 -137 -375 -162 P 2 1 0 0 -450 450 -450 500 P 2 1 0 0 -450 500 -500 500 P 2 1 0 0 -450 350 -450 300 P 2 1 0 0 -450 300 -500 300 P 2 1 0 0 100 100 100 150 P 2 1 0 0 100 150 100 250 P 2 1 0 0 100 250 100 300 P 2 1 0 0 100 300 300 200 P 2 1 0 0 300 200 100 100 P 2 1 0 0 100 150 50 150 P 2 1 0 0 112 250 137 250 P 2 1 0 0 112 150 137 150 P 2 1 0 0 125 162 125 137 P 2 1 0 0 -200 400 -150 400 P 2 1 0 0 -150 400 -100 400 P 2 1 0 0 0 400 50 400 P 2 1 0 0 50 400 100 400 P 2 1 0 0 300 200 337 200 P 2 1 0 0 337 200 337 400 P 2 1 0 0 337 400 200 400 P 2 1 0 0 337 200 400 200 P 2 1 0 0 -450 300 -450 200 P 2 1 0 0 -450 200 -300 200 P 2 1 0 0 -150 400 -150 200 P 2 1 0 0 -150 200 -200 200 P 2 1 0 0 50 400 50 250 P 2 1 0 0 50 250 100 250 P 2 1 0 0 -300 100 -450 100 P 2 1 0 0 -450 100 -450 0 P 2 1 0 0 -450 0 -450 -50 P 2 1 0 0 -200 100 -150 100 P 2 1 0 0 -150 100 -150 -100 P 2 1 0 0 -150 -100 -200 -100 P 2 1 0 0 -150 -100 -100 -100 P 2 1 0 0 0 -100 50 -100 P 2 1 0 0 50 -100 100 -100 P 2 1 0 0 -450 -150 -450 -200 P 2 1 0 0 -450 -200 -500 -200 P 2 1 0 0 -500 0 -450 0 P 2 1 0 0 50 150 50 -100 P 2 1 0 0 200 -100 400 -100 C -450 300 12 1 1 0 N C -150 400 12 1 1 0 N C 50 400 12 1 1 0 N C 337 200 12 1 1 0 N C -450 0 12 1 1 0 N C -150 -100 12 1 1 0 N C 50 -100 12 1 1 0 N X +IN 3 -700 -200 200 R 40 40 1 1 I X -IN 2 -700 500 200 R 40 40 1 1 I X OUT 6 600 200 200 L 40 40 1 1 O X REF 5 600 -100 200 L 40 40 1 1 P X RG 1 -700 300 200 R 40 40 1 1 P X RG@1 8 -700 0 200 R 40 40 1 1 P X V+ 7 600 -200 200 L 40 40 1 1 W X V- 4 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA114U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA114U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA114U F0 "IC" -400 925 50 H V L B F1 "INA114U" -400 -900 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 600 -300 650 P 2 1 0 0 -300 650 -300 750 P 2 1 0 0 -300 750 -300 800 P 2 1 0 0 -300 800 -100 700 P 2 1 0 0 -100 700 -300 600 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 0 675 0 700 P 2 1 0 0 0 700 0 725 P 2 1 0 0 0 725 100 725 P 2 1 0 0 100 725 100 700 P 2 1 0 0 100 700 100 675 P 2 1 0 0 100 675 0 675 P 2 1 0 0 -300 750 -350 750 P 2 1 0 0 300 725 300 700 P 2 1 0 0 300 700 300 675 P 2 1 0 0 300 675 200 675 P 2 1 0 0 200 675 200 700 P 2 1 0 0 200 700 200 725 P 2 1 0 0 200 725 300 725 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 300 175 P 2 1 0 0 300 175 300 200 P 2 1 0 0 300 200 300 225 P 2 1 0 0 300 225 200 225 P 2 1 0 0 -300 650 -350 650 P 2 1 0 0 -287 750 -262 750 P 2 1 0 0 -287 650 -262 650 P 2 1 0 0 -275 762 -275 737 P 2 1 0 0 -400 -800 500 -800 P 2 1 0 0 500 -800 500 200 P 2 1 0 0 500 200 500 500 P 2 1 0 0 500 500 500 700 P 2 1 0 0 500 700 500 900 P 2 1 0 0 500 900 -400 900 P 2 1 0 0 -400 900 -400 800 P 2 1 0 0 -400 800 -400 600 P 2 1 0 0 -400 600 -400 300 P 2 1 0 0 -400 300 -400 100 P 2 1 0 0 -400 100 -400 -800 P 2 1 0 0 -300 100 -300 150 P 2 1 0 0 -300 150 -300 250 P 2 1 0 0 -300 250 -300 300 P 2 1 0 0 -300 300 -100 200 P 2 1 0 0 -100 200 -300 100 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 0 225 P 2 1 0 0 0 225 0 200 P 2 1 0 0 0 200 0 175 P 2 1 0 0 0 175 100 175 P 2 1 0 0 -200 375 -200 400 P 2 1 0 0 -200 400 -200 425 P 2 1 0 0 -200 425 -100 425 P 2 1 0 0 -100 425 -100 400 P 2 1 0 0 -100 400 -100 375 P 2 1 0 0 -100 375 -200 375 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -300 150 -350 150 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -287 150 -262 150 P 2 1 0 0 -275 162 -275 137 P 2 1 0 0 -350 750 -350 800 P 2 1 0 0 -350 800 -400 800 P 2 1 0 0 -350 650 -350 600 P 2 1 0 0 -350 600 -400 600 P 2 1 0 0 200 400 200 450 P 2 1 0 0 200 450 200 550 P 2 1 0 0 200 550 200 600 P 2 1 0 0 200 600 400 500 P 2 1 0 0 400 500 200 400 P 2 1 0 0 200 450 150 450 P 2 1 0 0 212 550 237 550 P 2 1 0 0 212 450 237 450 P 2 1 0 0 225 462 225 437 P 2 1 0 0 -100 700 -50 700 P 2 1 0 0 -50 700 0 700 P 2 1 0 0 100 700 150 700 P 2 1 0 0 150 700 200 700 P 2 1 0 0 400 500 500 500 P 2 1 0 0 -350 600 -350 500 P 2 1 0 0 -350 500 -200 500 P 2 1 0 0 -50 700 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 150 700 150 550 P 2 1 0 0 150 550 200 550 P 2 1 0 0 -200 400 -350 400 P 2 1 0 0 -350 400 -350 300 P 2 1 0 0 -350 300 -350 250 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 0 200 P 2 1 0 0 100 200 150 200 P 2 1 0 0 150 200 200 200 P 2 1 0 0 -350 150 -350 100 P 2 1 0 0 -350 100 -400 100 P 2 1 0 0 -400 300 -350 300 P 2 1 0 0 150 450 150 200 P 2 1 0 0 300 200 500 200 P 2 1 0 0 500 700 300 700 C -350 600 12 1 1 0 N C -50 700 12 1 1 0 N C 150 700 12 1 1 0 N C -350 300 12 1 1 0 N C -50 200 12 1 1 0 N C 150 200 12 1 1 0 N T 0 -250 -200 60 0 1 0 NC T 0 -250 -300 60 0 1 0 NC T 0 -250 -400 60 0 1 0 NC T 0 -250 -500 60 0 1 0 NC T 0 -250 -600 60 0 1 0 NC T 0 -250 -700 60 0 1 0 NC X +IN 5 -500 100 100 R 40 40 1 1 I X -IN 4 -500 800 100 R 40 40 1 1 I X FB 12 600 700 100 L 40 40 1 1 P X NC 1 -500 -100 100 R 40 40 1 1 U X NC@1 3 -500 -200 100 R 40 40 1 1 U X NC@2 6 -500 -300 100 R 40 40 1 1 U X NC@3 8 -500 -400 100 R 40 40 1 1 U X NC@4 9 -500 -500 100 R 40 40 1 1 U X NC@5 14 -500 -600 100 R 40 40 1 1 U X NC@6 16 -500 -700 100 R 40 40 1 1 U X OUT 11 600 500 100 L 40 40 1 1 O X REF 10 600 200 100 L 40 40 1 1 P X RG 2 -500 600 100 R 40 40 1 1 P X RG@1 15 -500 300 100 R 40 40 1 1 P X V+ 13 600 -500 100 L 40 40 1 1 W X V- 7 600 -700 100 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA116P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA116P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA116 F0 "IC" -600 925 50 H V L B F1 "INA116P" -600 -800 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 500 -300 550 P 2 1 0 0 -300 550 -300 650 P 2 1 0 0 -300 650 -300 700 P 2 1 0 0 -300 700 -100 600 P 2 1 0 0 -100 600 -300 500 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 0 575 0 600 P 2 1 0 0 0 600 0 625 P 2 1 0 0 0 625 100 625 P 2 1 0 0 100 625 100 600 P 2 1 0 0 100 600 100 575 P 2 1 0 0 100 575 0 575 P 2 1 0 0 -300 650 -350 650 P 2 1 0 0 300 625 300 600 P 2 1 0 0 300 600 300 575 P 2 1 0 0 300 575 200 575 P 2 1 0 0 200 575 200 600 P 2 1 0 0 200 600 200 625 P 2 1 0 0 200 625 300 625 P 2 1 0 0 200 125 200 100 P 2 1 0 0 200 100 200 75 P 2 1 0 0 200 75 300 75 P 2 1 0 0 300 75 300 100 P 2 1 0 0 300 100 300 125 P 2 1 0 0 300 125 200 125 P 2 1 0 0 -300 550 -350 550 P 2 1 0 0 -287 650 -262 650 P 2 1 0 0 -287 550 -262 550 P 2 1 0 0 -275 662 -275 637 P 2 1 0 0 -600 -700 500 -700 P 2 1 0 0 500 -700 500 100 P 2 1 0 0 500 100 500 400 P 2 1 0 0 500 400 500 900 P 2 1 0 0 500 900 -600 900 P 2 1 0 0 -600 900 -600 800 P 2 1 0 0 -600 800 -600 700 P 2 1 0 0 -600 700 -600 600 P 2 1 0 0 -600 600 -600 500 P 2 1 0 0 -600 500 -600 200 P 2 1 0 0 -600 200 -600 100 P 2 1 0 0 -600 100 -600 0 P 2 1 0 0 -600 0 -600 -100 P 2 1 0 0 -600 -100 -600 -700 P 2 1 0 0 -300 0 -300 50 P 2 1 0 0 -300 50 -300 150 P 2 1 0 0 -300 150 -300 200 P 2 1 0 0 -300 200 -100 100 P 2 1 0 0 -100 100 -300 0 P 2 1 0 0 100 75 100 100 P 2 1 0 0 100 100 100 125 P 2 1 0 0 100 125 0 125 P 2 1 0 0 0 125 0 100 P 2 1 0 0 0 100 0 75 P 2 1 0 0 0 75 100 75 P 2 1 0 0 -200 275 -200 300 P 2 1 0 0 -200 300 -200 325 P 2 1 0 0 -200 325 -100 325 P 2 1 0 0 -100 325 -100 300 P 2 1 0 0 -100 300 -100 275 P 2 1 0 0 -100 275 -200 275 P 2 1 0 0 -300 150 -350 150 P 2 1 0 0 -300 50 -350 50 P 2 1 0 0 -287 150 -262 150 P 2 1 0 0 -287 50 -262 50 P 2 1 0 0 -275 62 -275 37 P 2 1 0 0 -350 650 -350 700 P 2 1 0 0 -350 550 -350 500 P 2 1 0 0 -350 500 -600 500 P 2 1 0 0 200 300 200 350 P 2 1 0 0 200 350 200 450 P 2 1 0 0 200 450 200 500 P 2 1 0 0 200 500 400 400 P 2 1 0 0 400 400 200 300 P 2 1 0 0 200 350 150 350 P 2 1 0 0 212 450 237 450 P 2 1 0 0 212 350 237 350 P 2 1 0 0 225 362 225 337 P 2 1 0 0 -100 600 -50 600 P 2 1 0 0 -50 600 0 600 P 2 1 0 0 100 600 150 600 P 2 1 0 0 150 600 200 600 P 2 1 0 0 400 400 437 400 P 2 1 0 0 437 400 437 600 P 2 1 0 0 437 600 300 600 P 2 1 0 0 437 400 500 400 P 2 1 0 0 -350 500 -350 400 P 2 1 0 0 -350 400 -200 400 P 2 1 0 0 -50 600 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 150 600 150 450 P 2 1 0 0 150 450 200 450 P 2 1 0 0 -200 300 -350 300 P 2 1 0 0 -350 300 -350 200 P 2 1 0 0 -350 200 -350 150 P 2 1 0 0 -100 300 -50 300 P 2 1 0 0 -50 300 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -50 100 0 100 P 2 1 0 0 100 100 150 100 P 2 1 0 0 150 100 200 100 P 2 1 0 0 -350 50 -350 0 P 2 1 0 0 -600 200 -350 200 P 2 1 0 0 150 350 150 100 P 2 1 0 0 300 100 500 100 P 2 1 0 0 -400 0 -450 25 P 2 1 0 0 -450 25 -500 50 P 2 1 0 0 -500 50 -500 0 P 2 1 0 0 -500 0 -500 -50 P 2 1 0 0 -500 -50 -450 -25 P 2 1 0 0 -450 -25 -400 0 P 2 1 0 0 -400 700 -450 725 P 2 1 0 0 -450 725 -500 750 P 2 1 0 0 -500 750 -500 700 P 2 1 0 0 -500 700 -500 650 P 2 1 0 0 -500 650 -450 675 P 2 1 0 0 -450 675 -400 700 P 2 1 0 0 -500 0 -600 0 P 2 1 0 0 -600 700 -500 700 P 2 1 0 0 -600 800 -450 800 P 2 1 0 0 -450 800 -450 725 P 2 1 0 0 -450 675 -450 600 P 2 1 0 0 -450 600 -600 600 P 2 1 0 0 -400 700 -350 700 P 2 1 0 0 -400 0 -350 0 P 2 1 0 0 -600 100 -450 100 P 2 1 0 0 -450 100 -450 25 P 2 1 0 0 -450 -25 -450 -100 P 2 1 0 0 -450 -100 -600 -100 C -350 500 12 1 1 0 N C -50 600 12 1 1 0 N C 150 600 12 1 1 0 N C 437 400 12 1 1 0 N C -350 200 12 1 1 0 N C -50 100 12 1 1 0 N C 150 100 12 1 1 0 N X +IN 6 -800 0 200 R 40 40 1 1 I X -IN 3 -800 700 200 R 40 40 1 1 I X GUARD+ 5 -800 100 200 R 40 40 1 1 P X GUARD+@1 7 -800 -100 200 R 40 40 1 1 P X GUARD- 2 -800 800 200 R 40 40 1 1 P X GUARD-@1 4 -800 600 200 R 40 40 1 1 P X NC 10 -800 -300 200 R 40 40 1 1 U X NC@1 12 -800 -400 200 R 40 40 1 1 U X NC@2 14 -800 -500 200 R 40 40 1 1 U X NC@3 15 -800 -600 200 R 40 40 1 1 U X OUT 11 700 400 200 L 40 40 1 1 O X REF 9 700 100 200 L 40 40 1 1 P X RG 1 -800 500 200 R 40 40 1 1 P X RG@1 16 -800 200 200 R 40 40 1 1 P X V+ 13 700 -400 200 L 40 40 1 1 W X V- 8 700 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA116U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA116U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA116 F0 "IC" -600 925 50 H V L B F1 "INA116U" -600 -800 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 500 -300 550 P 2 1 0 0 -300 550 -300 650 P 2 1 0 0 -300 650 -300 700 P 2 1 0 0 -300 700 -100 600 P 2 1 0 0 -100 600 -300 500 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 0 575 0 600 P 2 1 0 0 0 600 0 625 P 2 1 0 0 0 625 100 625 P 2 1 0 0 100 625 100 600 P 2 1 0 0 100 600 100 575 P 2 1 0 0 100 575 0 575 P 2 1 0 0 -300 650 -350 650 P 2 1 0 0 300 625 300 600 P 2 1 0 0 300 600 300 575 P 2 1 0 0 300 575 200 575 P 2 1 0 0 200 575 200 600 P 2 1 0 0 200 600 200 625 P 2 1 0 0 200 625 300 625 P 2 1 0 0 200 125 200 100 P 2 1 0 0 200 100 200 75 P 2 1 0 0 200 75 300 75 P 2 1 0 0 300 75 300 100 P 2 1 0 0 300 100 300 125 P 2 1 0 0 300 125 200 125 P 2 1 0 0 -300 550 -350 550 P 2 1 0 0 -287 650 -262 650 P 2 1 0 0 -287 550 -262 550 P 2 1 0 0 -275 662 -275 637 P 2 1 0 0 -600 -700 500 -700 P 2 1 0 0 500 -700 500 100 P 2 1 0 0 500 100 500 400 P 2 1 0 0 500 400 500 900 P 2 1 0 0 500 900 -600 900 P 2 1 0 0 -600 900 -600 800 P 2 1 0 0 -600 800 -600 700 P 2 1 0 0 -600 700 -600 600 P 2 1 0 0 -600 600 -600 500 P 2 1 0 0 -600 500 -600 200 P 2 1 0 0 -600 200 -600 100 P 2 1 0 0 -600 100 -600 0 P 2 1 0 0 -600 0 -600 -100 P 2 1 0 0 -600 -100 -600 -700 P 2 1 0 0 -300 0 -300 50 P 2 1 0 0 -300 50 -300 150 P 2 1 0 0 -300 150 -300 200 P 2 1 0 0 -300 200 -100 100 P 2 1 0 0 -100 100 -300 0 P 2 1 0 0 100 75 100 100 P 2 1 0 0 100 100 100 125 P 2 1 0 0 100 125 0 125 P 2 1 0 0 0 125 0 100 P 2 1 0 0 0 100 0 75 P 2 1 0 0 0 75 100 75 P 2 1 0 0 -200 275 -200 300 P 2 1 0 0 -200 300 -200 325 P 2 1 0 0 -200 325 -100 325 P 2 1 0 0 -100 325 -100 300 P 2 1 0 0 -100 300 -100 275 P 2 1 0 0 -100 275 -200 275 P 2 1 0 0 -300 150 -350 150 P 2 1 0 0 -300 50 -350 50 P 2 1 0 0 -287 150 -262 150 P 2 1 0 0 -287 50 -262 50 P 2 1 0 0 -275 62 -275 37 P 2 1 0 0 -350 650 -350 700 P 2 1 0 0 -350 550 -350 500 P 2 1 0 0 -350 500 -600 500 P 2 1 0 0 200 300 200 350 P 2 1 0 0 200 350 200 450 P 2 1 0 0 200 450 200 500 P 2 1 0 0 200 500 400 400 P 2 1 0 0 400 400 200 300 P 2 1 0 0 200 350 150 350 P 2 1 0 0 212 450 237 450 P 2 1 0 0 212 350 237 350 P 2 1 0 0 225 362 225 337 P 2 1 0 0 -100 600 -50 600 P 2 1 0 0 -50 600 0 600 P 2 1 0 0 100 600 150 600 P 2 1 0 0 150 600 200 600 P 2 1 0 0 400 400 437 400 P 2 1 0 0 437 400 437 600 P 2 1 0 0 437 600 300 600 P 2 1 0 0 437 400 500 400 P 2 1 0 0 -350 500 -350 400 P 2 1 0 0 -350 400 -200 400 P 2 1 0 0 -50 600 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 150 600 150 450 P 2 1 0 0 150 450 200 450 P 2 1 0 0 -200 300 -350 300 P 2 1 0 0 -350 300 -350 200 P 2 1 0 0 -350 200 -350 150 P 2 1 0 0 -100 300 -50 300 P 2 1 0 0 -50 300 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -50 100 0 100 P 2 1 0 0 100 100 150 100 P 2 1 0 0 150 100 200 100 P 2 1 0 0 -350 50 -350 0 P 2 1 0 0 -600 200 -350 200 P 2 1 0 0 150 350 150 100 P 2 1 0 0 300 100 500 100 P 2 1 0 0 -400 0 -450 25 P 2 1 0 0 -450 25 -500 50 P 2 1 0 0 -500 50 -500 0 P 2 1 0 0 -500 0 -500 -50 P 2 1 0 0 -500 -50 -450 -25 P 2 1 0 0 -450 -25 -400 0 P 2 1 0 0 -400 700 -450 725 P 2 1 0 0 -450 725 -500 750 P 2 1 0 0 -500 750 -500 700 P 2 1 0 0 -500 700 -500 650 P 2 1 0 0 -500 650 -450 675 P 2 1 0 0 -450 675 -400 700 P 2 1 0 0 -500 0 -600 0 P 2 1 0 0 -600 700 -500 700 P 2 1 0 0 -600 800 -450 800 P 2 1 0 0 -450 800 -450 725 P 2 1 0 0 -450 675 -450 600 P 2 1 0 0 -450 600 -600 600 P 2 1 0 0 -400 700 -350 700 P 2 1 0 0 -400 0 -350 0 P 2 1 0 0 -600 100 -450 100 P 2 1 0 0 -450 100 -450 25 P 2 1 0 0 -450 -25 -450 -100 P 2 1 0 0 -450 -100 -600 -100 C -350 500 12 1 1 0 N C -50 600 12 1 1 0 N C 150 600 12 1 1 0 N C 437 400 12 1 1 0 N C -350 200 12 1 1 0 N C -50 100 12 1 1 0 N C 150 100 12 1 1 0 N X +IN 6 -800 0 200 R 40 40 1 1 I X -IN 3 -800 700 200 R 40 40 1 1 I X GUARD+ 5 -800 100 200 R 40 40 1 1 P X GUARD+@1 7 -800 -100 200 R 40 40 1 1 P X GUARD- 2 -800 800 200 R 40 40 1 1 P X GUARD-@1 4 -800 600 200 R 40 40 1 1 P X NC 10 -800 -300 200 R 40 40 1 1 U X NC@1 12 -800 -400 200 R 40 40 1 1 U X NC@2 14 -800 -500 200 R 40 40 1 1 U X NC@3 15 -800 -600 200 R 40 40 1 1 U X OUT 11 700 400 200 L 40 40 1 1 O X REF 9 700 100 200 L 40 40 1 1 P X RG 1 -800 500 200 R 40 40 1 1 P X RG@1 16 -800 200 200 R 40 40 1 1 P X V+ 13 700 -400 200 L 40 40 1 1 W X V- 8 700 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA117M # Package Name: TO99 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA117M IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA117 F0 "IC" -300 425 50 H V L B F1 "INA117M" -300 -700 50 H V L B F2 "burr-brown-TO99" 0 150 50 H I C C DRAW P 2 1 0 0 0 -100 0 -50 P 2 1 0 0 0 -50 0 50 P 2 1 0 0 0 50 0 100 P 2 1 0 0 0 100 200 0 P 2 1 0 0 200 0 0 -100 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 200 225 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 100 175 P 2 1 0 0 0 50 -50 50 P 2 1 0 0 -100 -175 -100 -200 P 2 1 0 0 -100 -200 -100 -225 P 2 1 0 0 -100 -225 -200 -225 P 2 1 0 0 -200 -225 -200 -200 P 2 1 0 0 -200 -200 -200 -175 P 2 1 0 0 -200 -175 -100 -175 P 2 1 0 0 100 -175 100 -200 P 2 1 0 0 100 -200 100 -225 P 2 1 0 0 100 -225 200 -225 P 2 1 0 0 200 -225 200 -200 P 2 1 0 0 200 -200 200 -175 P 2 1 0 0 200 -175 100 -175 P 2 1 0 0 -50 50 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 100 200 P 2 1 0 0 0 -50 -50 -50 P 2 1 0 0 -50 -50 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 100 -200 P 2 1 0 0 12 50 37 50 P 2 1 0 0 12 -50 37 -50 P 2 1 0 0 25 -37 25 -62 P 2 1 0 0 -300 200 -200 200 P 2 1 0 0 250 200 200 200 P 2 1 0 0 200 0 250 0 P 2 1 0 0 250 0 300 0 P 2 1 0 0 300 -200 200 -200 P 2 1 0 0 -300 -200 -200 -200 P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -600 P 2 1 0 0 -100 275 -100 300 P 2 1 0 0 -100 300 -100 325 P 2 1 0 0 -100 325 -200 325 P 2 1 0 0 -200 325 -200 300 P 2 1 0 0 -200 300 -200 275 P 2 1 0 0 -200 275 -100 275 P 2 1 0 0 -50 300 -100 300 P 2 1 0 0 -300 300 -200 300 P 2 1 0 0 250 200 250 0 P 2 1 0 0 -50 300 -50 200 C -50 200 12 1 1 0 N C -50 -200 12 1 1 0 N C 250 0 12 1 1 0 N X +IN 3 -500 -200 200 R 40 40 1 1 I X -IN 2 -500 200 200 R 40 40 1 1 I X COMP 8 -500 -500 200 R 40 40 1 1 P X OUT 6 500 0 200 L 40 40 1 1 O X REFA 5 500 -200 200 L 40 40 1 1 I X REFB 1 -500 300 200 R 40 40 1 1 I X V+ 7 500 -300 200 L 40 40 1 1 W X V- 4 500 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA117P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA117P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA117 F0 "IC" -300 425 50 H V L B F1 "INA117P" -300 -700 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 0 -100 0 -50 P 2 1 0 0 0 -50 0 50 P 2 1 0 0 0 50 0 100 P 2 1 0 0 0 100 200 0 P 2 1 0 0 200 0 0 -100 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 200 225 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 100 175 P 2 1 0 0 0 50 -50 50 P 2 1 0 0 -100 -175 -100 -200 P 2 1 0 0 -100 -200 -100 -225 P 2 1 0 0 -100 -225 -200 -225 P 2 1 0 0 -200 -225 -200 -200 P 2 1 0 0 -200 -200 -200 -175 P 2 1 0 0 -200 -175 -100 -175 P 2 1 0 0 100 -175 100 -200 P 2 1 0 0 100 -200 100 -225 P 2 1 0 0 100 -225 200 -225 P 2 1 0 0 200 -225 200 -200 P 2 1 0 0 200 -200 200 -175 P 2 1 0 0 200 -175 100 -175 P 2 1 0 0 -50 50 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 100 200 P 2 1 0 0 0 -50 -50 -50 P 2 1 0 0 -50 -50 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 100 -200 P 2 1 0 0 12 50 37 50 P 2 1 0 0 12 -50 37 -50 P 2 1 0 0 25 -37 25 -62 P 2 1 0 0 -300 200 -200 200 P 2 1 0 0 250 200 200 200 P 2 1 0 0 200 0 250 0 P 2 1 0 0 250 0 300 0 P 2 1 0 0 300 -200 200 -200 P 2 1 0 0 -300 -200 -200 -200 P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -600 P 2 1 0 0 -100 275 -100 300 P 2 1 0 0 -100 300 -100 325 P 2 1 0 0 -100 325 -200 325 P 2 1 0 0 -200 325 -200 300 P 2 1 0 0 -200 300 -200 275 P 2 1 0 0 -200 275 -100 275 P 2 1 0 0 -50 300 -100 300 P 2 1 0 0 -300 300 -200 300 P 2 1 0 0 250 200 250 0 P 2 1 0 0 -50 300 -50 200 C -50 200 12 1 1 0 N C -50 -200 12 1 1 0 N C 250 0 12 1 1 0 N X +IN 3 -500 -200 200 R 40 40 1 1 I X -IN 2 -500 200 200 R 40 40 1 1 I X COMP 8 -500 -500 200 R 40 40 1 1 P X OUT 6 500 0 200 L 40 40 1 1 O X REFA 5 500 -200 200 L 40 40 1 1 I X REFB 1 -500 300 200 R 40 40 1 1 I X V+ 7 500 -300 200 L 40 40 1 1 W X V- 4 500 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA117U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA117U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA117 F0 "IC" -300 425 50 H V L B F1 "INA117U" -300 -700 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 0 -100 0 -50 P 2 1 0 0 0 -50 0 50 P 2 1 0 0 0 50 0 100 P 2 1 0 0 0 100 200 0 P 2 1 0 0 200 0 0 -100 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 200 225 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 100 175 P 2 1 0 0 0 50 -50 50 P 2 1 0 0 -100 -175 -100 -200 P 2 1 0 0 -100 -200 -100 -225 P 2 1 0 0 -100 -225 -200 -225 P 2 1 0 0 -200 -225 -200 -200 P 2 1 0 0 -200 -200 -200 -175 P 2 1 0 0 -200 -175 -100 -175 P 2 1 0 0 100 -175 100 -200 P 2 1 0 0 100 -200 100 -225 P 2 1 0 0 100 -225 200 -225 P 2 1 0 0 200 -225 200 -200 P 2 1 0 0 200 -200 200 -175 P 2 1 0 0 200 -175 100 -175 P 2 1 0 0 -50 50 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 100 200 P 2 1 0 0 0 -50 -50 -50 P 2 1 0 0 -50 -50 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 100 -200 P 2 1 0 0 12 50 37 50 P 2 1 0 0 12 -50 37 -50 P 2 1 0 0 25 -37 25 -62 P 2 1 0 0 -300 200 -200 200 P 2 1 0 0 250 200 200 200 P 2 1 0 0 200 0 250 0 P 2 1 0 0 250 0 300 0 P 2 1 0 0 300 -200 200 -200 P 2 1 0 0 -300 -200 -200 -200 P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -600 P 2 1 0 0 -100 275 -100 300 P 2 1 0 0 -100 300 -100 325 P 2 1 0 0 -100 325 -200 325 P 2 1 0 0 -200 325 -200 300 P 2 1 0 0 -200 300 -200 275 P 2 1 0 0 -200 275 -100 275 P 2 1 0 0 -50 300 -100 300 P 2 1 0 0 -300 300 -200 300 P 2 1 0 0 250 200 250 0 P 2 1 0 0 -50 300 -50 200 C -50 200 12 1 1 0 N C -50 -200 12 1 1 0 N C 250 0 12 1 1 0 N X +IN 3 -500 -200 200 R 40 40 1 1 I X -IN 2 -500 200 200 R 40 40 1 1 I X COMP 8 -500 -500 200 R 40 40 1 1 P X OUT 6 500 0 200 L 40 40 1 1 O X REFA 5 500 -200 200 L 40 40 1 1 I X REFB 1 -500 300 200 R 40 40 1 1 I X V+ 7 500 -300 200 L 40 40 1 1 W X V- 4 500 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA118P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA118P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA118 F0 "IC" -500 625 50 H V L B F1 "INA118P" -500 -600 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -400 300 -400 350 P 2 1 0 0 -400 350 -400 450 P 2 1 0 0 -400 450 -400 500 P 2 1 0 0 -400 500 -200 400 P 2 1 0 0 -200 400 -400 300 P 2 1 0 0 -200 175 -200 200 P 2 1 0 0 -200 200 -200 225 P 2 1 0 0 -200 225 -300 225 P 2 1 0 0 -300 225 -300 200 P 2 1 0 0 -300 200 -300 175 P 2 1 0 0 -300 175 -200 175 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 0 425 P 2 1 0 0 0 425 0 400 P 2 1 0 0 0 400 0 375 P 2 1 0 0 0 375 -100 375 P 2 1 0 0 -400 450 -450 450 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 100 -75 100 -100 P 2 1 0 0 100 -100 100 -125 P 2 1 0 0 100 -125 200 -125 P 2 1 0 0 200 -125 200 -100 P 2 1 0 0 200 -100 200 -75 P 2 1 0 0 200 -75 100 -75 P 2 1 0 0 -400 350 -450 350 P 2 1 0 0 -387 450 -362 450 P 2 1 0 0 -387 350 -362 350 P 2 1 0 0 -375 462 -375 437 P 2 1 0 0 -500 -500 400 -500 P 2 1 0 0 400 -500 400 -100 P 2 1 0 0 400 -100 400 200 P 2 1 0 0 400 200 400 600 P 2 1 0 0 400 600 -500 600 P 2 1 0 0 -500 600 -500 500 P 2 1 0 0 -500 500 -500 300 P 2 1 0 0 -500 300 -500 0 P 2 1 0 0 -500 0 -500 -200 P 2 1 0 0 -500 -200 -500 -500 P 2 1 0 0 -400 -200 -400 -150 P 2 1 0 0 -400 -150 -400 -50 P 2 1 0 0 -400 -50 -400 0 P 2 1 0 0 -400 0 -200 -100 P 2 1 0 0 -200 -100 -400 -200 P 2 1 0 0 0 -125 0 -100 P 2 1 0 0 0 -100 0 -75 P 2 1 0 0 0 -75 -100 -75 P 2 1 0 0 -100 -75 -100 -100 P 2 1 0 0 -100 -100 -100 -125 P 2 1 0 0 -100 -125 0 -125 P 2 1 0 0 -300 75 -300 100 P 2 1 0 0 -300 100 -300 125 P 2 1 0 0 -300 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -300 75 P 2 1 0 0 -400 -50 -450 -50 P 2 1 0 0 -400 -150 -450 -150 P 2 1 0 0 -387 -50 -362 -50 P 2 1 0 0 -387 -150 -362 -150 P 2 1 0 0 -375 -137 -375 -162 P 2 1 0 0 -450 450 -450 500 P 2 1 0 0 -450 500 -500 500 P 2 1 0 0 -450 350 -450 300 P 2 1 0 0 -450 300 -500 300 P 2 1 0 0 100 100 100 150 P 2 1 0 0 100 150 100 250 P 2 1 0 0 100 250 100 300 P 2 1 0 0 100 300 300 200 P 2 1 0 0 300 200 100 100 P 2 1 0 0 100 150 50 150 P 2 1 0 0 112 250 137 250 P 2 1 0 0 112 150 137 150 P 2 1 0 0 125 162 125 137 P 2 1 0 0 -200 400 -150 400 P 2 1 0 0 -150 400 -100 400 P 2 1 0 0 0 400 50 400 P 2 1 0 0 50 400 100 400 P 2 1 0 0 300 200 337 200 P 2 1 0 0 337 200 337 400 P 2 1 0 0 337 400 200 400 P 2 1 0 0 337 200 400 200 P 2 1 0 0 -450 300 -450 200 P 2 1 0 0 -450 200 -300 200 P 2 1 0 0 -150 400 -150 200 P 2 1 0 0 -150 200 -200 200 P 2 1 0 0 50 400 50 250 P 2 1 0 0 50 250 100 250 P 2 1 0 0 -300 100 -450 100 P 2 1 0 0 -450 100 -450 0 P 2 1 0 0 -450 0 -450 -50 P 2 1 0 0 -200 100 -150 100 P 2 1 0 0 -150 100 -150 -100 P 2 1 0 0 -150 -100 -200 -100 P 2 1 0 0 -150 -100 -100 -100 P 2 1 0 0 0 -100 50 -100 P 2 1 0 0 50 -100 100 -100 P 2 1 0 0 -450 -150 -450 -200 P 2 1 0 0 -450 -200 -500 -200 P 2 1 0 0 -500 0 -450 0 P 2 1 0 0 50 150 50 -100 P 2 1 0 0 200 -100 400 -100 C -450 300 12 1 1 0 N C -150 400 12 1 1 0 N C 50 400 12 1 1 0 N C 337 200 12 1 1 0 N C -450 0 12 1 1 0 N C -150 -100 12 1 1 0 N C 50 -100 12 1 1 0 N X +IN 3 -700 -200 200 R 40 40 1 1 I X -IN 2 -700 500 200 R 40 40 1 1 I X OUT 6 600 200 200 L 40 40 1 1 O X REF 5 600 -100 200 L 40 40 1 1 P X RG 1 -700 300 200 R 40 40 1 1 P X RG@1 8 -700 0 200 R 40 40 1 1 P X V+ 7 600 -200 200 L 40 40 1 1 W X V- 4 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA118U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA118U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA118 F0 "IC" -500 625 50 H V L B F1 "INA118U" -500 -600 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -400 300 -400 350 P 2 1 0 0 -400 350 -400 450 P 2 1 0 0 -400 450 -400 500 P 2 1 0 0 -400 500 -200 400 P 2 1 0 0 -200 400 -400 300 P 2 1 0 0 -200 175 -200 200 P 2 1 0 0 -200 200 -200 225 P 2 1 0 0 -200 225 -300 225 P 2 1 0 0 -300 225 -300 200 P 2 1 0 0 -300 200 -300 175 P 2 1 0 0 -300 175 -200 175 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 0 425 P 2 1 0 0 0 425 0 400 P 2 1 0 0 0 400 0 375 P 2 1 0 0 0 375 -100 375 P 2 1 0 0 -400 450 -450 450 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 100 -75 100 -100 P 2 1 0 0 100 -100 100 -125 P 2 1 0 0 100 -125 200 -125 P 2 1 0 0 200 -125 200 -100 P 2 1 0 0 200 -100 200 -75 P 2 1 0 0 200 -75 100 -75 P 2 1 0 0 -400 350 -450 350 P 2 1 0 0 -387 450 -362 450 P 2 1 0 0 -387 350 -362 350 P 2 1 0 0 -375 462 -375 437 P 2 1 0 0 -500 -500 400 -500 P 2 1 0 0 400 -500 400 -100 P 2 1 0 0 400 -100 400 200 P 2 1 0 0 400 200 400 600 P 2 1 0 0 400 600 -500 600 P 2 1 0 0 -500 600 -500 500 P 2 1 0 0 -500 500 -500 300 P 2 1 0 0 -500 300 -500 0 P 2 1 0 0 -500 0 -500 -200 P 2 1 0 0 -500 -200 -500 -500 P 2 1 0 0 -400 -200 -400 -150 P 2 1 0 0 -400 -150 -400 -50 P 2 1 0 0 -400 -50 -400 0 P 2 1 0 0 -400 0 -200 -100 P 2 1 0 0 -200 -100 -400 -200 P 2 1 0 0 0 -125 0 -100 P 2 1 0 0 0 -100 0 -75 P 2 1 0 0 0 -75 -100 -75 P 2 1 0 0 -100 -75 -100 -100 P 2 1 0 0 -100 -100 -100 -125 P 2 1 0 0 -100 -125 0 -125 P 2 1 0 0 -300 75 -300 100 P 2 1 0 0 -300 100 -300 125 P 2 1 0 0 -300 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -300 75 P 2 1 0 0 -400 -50 -450 -50 P 2 1 0 0 -400 -150 -450 -150 P 2 1 0 0 -387 -50 -362 -50 P 2 1 0 0 -387 -150 -362 -150 P 2 1 0 0 -375 -137 -375 -162 P 2 1 0 0 -450 450 -450 500 P 2 1 0 0 -450 500 -500 500 P 2 1 0 0 -450 350 -450 300 P 2 1 0 0 -450 300 -500 300 P 2 1 0 0 100 100 100 150 P 2 1 0 0 100 150 100 250 P 2 1 0 0 100 250 100 300 P 2 1 0 0 100 300 300 200 P 2 1 0 0 300 200 100 100 P 2 1 0 0 100 150 50 150 P 2 1 0 0 112 250 137 250 P 2 1 0 0 112 150 137 150 P 2 1 0 0 125 162 125 137 P 2 1 0 0 -200 400 -150 400 P 2 1 0 0 -150 400 -100 400 P 2 1 0 0 0 400 50 400 P 2 1 0 0 50 400 100 400 P 2 1 0 0 300 200 337 200 P 2 1 0 0 337 200 337 400 P 2 1 0 0 337 400 200 400 P 2 1 0 0 337 200 400 200 P 2 1 0 0 -450 300 -450 200 P 2 1 0 0 -450 200 -300 200 P 2 1 0 0 -150 400 -150 200 P 2 1 0 0 -150 200 -200 200 P 2 1 0 0 50 400 50 250 P 2 1 0 0 50 250 100 250 P 2 1 0 0 -300 100 -450 100 P 2 1 0 0 -450 100 -450 0 P 2 1 0 0 -450 0 -450 -50 P 2 1 0 0 -200 100 -150 100 P 2 1 0 0 -150 100 -150 -100 P 2 1 0 0 -150 -100 -200 -100 P 2 1 0 0 -150 -100 -100 -100 P 2 1 0 0 0 -100 50 -100 P 2 1 0 0 50 -100 100 -100 P 2 1 0 0 -450 -150 -450 -200 P 2 1 0 0 -450 -200 -500 -200 P 2 1 0 0 -500 0 -450 0 P 2 1 0 0 50 150 50 -100 P 2 1 0 0 200 -100 400 -100 C -450 300 12 1 1 0 N C -150 400 12 1 1 0 N C 50 400 12 1 1 0 N C 337 200 12 1 1 0 N C -450 0 12 1 1 0 N C -150 -100 12 1 1 0 N C 50 -100 12 1 1 0 N X +IN 3 -700 -200 200 R 40 40 1 1 I X -IN 2 -700 500 200 R 40 40 1 1 I X OUT 6 600 200 200 L 40 40 1 1 O X REF 5 600 -100 200 L 40 40 1 1 P X RG 1 -700 300 200 R 40 40 1 1 P X RG@1 8 -700 0 200 R 40 40 1 1 P X V+ 7 600 -200 200 L 40 40 1 1 W X V- 4 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA122P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA122P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA122 F0 "IC" -400 725 50 H V L B F1 "INA122P" -400 -800 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -100 400 -100 450 P 2 1 0 0 -100 450 -100 550 P 2 1 0 0 -100 550 -100 600 P 2 1 0 0 -100 600 100 500 P 2 1 0 0 100 500 -100 400 P 2 1 0 0 -100 550 -150 550 P 2 1 0 0 50 225 50 200 P 2 1 0 0 50 200 50 175 P 2 1 0 0 50 175 -50 175 P 2 1 0 0 -50 175 -50 200 P 2 1 0 0 -50 200 -50 225 P 2 1 0 0 -50 225 50 225 P 2 1 0 0 -50 325 -50 300 P 2 1 0 0 -50 300 -50 275 P 2 1 0 0 -50 275 50 275 P 2 1 0 0 50 275 50 300 P 2 1 0 0 50 300 50 325 P 2 1 0 0 50 325 -50 325 P 2 1 0 0 -100 450 -200 450 P 2 1 0 0 -200 450 -200 400 P 2 1 0 0 -87 550 -62 550 P 2 1 0 0 -87 450 -62 450 P 2 1 0 0 -75 562 -75 537 P 2 1 0 0 100 500 175 500 P 2 1 0 0 175 500 300 500 P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 -300 P 2 1 0 0 300 -300 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 600 P 2 1 0 0 -300 600 -300 400 P 2 1 0 0 -300 400 -300 0 P 2 1 0 0 -300 0 -300 -200 P 2 1 0 0 -300 -200 -300 -700 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 50 75 50 100 P 2 1 0 0 50 100 50 125 P 2 1 0 0 50 125 -50 125 P 2 1 0 0 -50 125 -50 100 P 2 1 0 0 -50 100 -50 75 P 2 1 0 0 -50 75 50 75 P 2 1 0 0 -50 -325 -50 -300 P 2 1 0 0 -50 -300 -50 -275 P 2 1 0 0 -50 -275 50 -275 P 2 1 0 0 50 -275 50 -300 P 2 1 0 0 50 -300 50 -325 P 2 1 0 0 50 -325 -50 -325 P 2 1 0 0 -100 -50 -200 -50 P 2 1 0 0 -200 -50 -200 0 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -100 175 -100 P 2 1 0 0 -300 600 -150 600 P 2 1 0 0 -150 600 -150 550 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 175 500 175 300 P 2 1 0 0 175 300 50 300 P 2 1 0 0 -200 400 -200 300 P 2 1 0 0 -200 300 -50 300 P 2 1 0 0 -150 -150 -150 -200 P 2 1 0 0 -150 -200 -300 -200 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -200 200 -50 200 P 2 1 0 0 -200 300 -200 200 P 2 1 0 0 50 200 175 200 P 2 1 0 0 175 200 175 -100 P 2 1 0 0 50 100 162 100 P 2 1 0 0 -50 100 -200 100 P 2 1 0 0 -200 100 -200 0 P 2 1 0 0 -200 -50 -200 -300 P 2 1 0 0 50 -300 300 -300 P 2 1 0 0 -200 -300 -50 -300 C -200 400 12 1 1 0 N C -200 300 12 1 1 0 N C -200 0 12 1 1 0 N C -200 -50 12 1 1 0 N C 175 100 12 1 1 0 N C 175 500 12 1 1 0 N X +IN 3 -500 600 200 R 40 40 1 1 I X -IN 2 -500 -200 200 R 40 40 1 1 I X OUT 6 500 500 200 L 40 40 1 1 O X REF 5 500 -300 200 L 40 40 1 1 P X RG 1 -500 400 200 R 40 40 1 1 P X RG@1 8 -500 0 200 R 40 40 1 1 P X V+ 7 500 -400 200 L 40 40 1 1 W X V- 4 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA122U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA122U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA122 F0 "IC" -400 725 50 H V L B F1 "INA122U" -400 -800 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -100 400 -100 450 P 2 1 0 0 -100 450 -100 550 P 2 1 0 0 -100 550 -100 600 P 2 1 0 0 -100 600 100 500 P 2 1 0 0 100 500 -100 400 P 2 1 0 0 -100 550 -150 550 P 2 1 0 0 50 225 50 200 P 2 1 0 0 50 200 50 175 P 2 1 0 0 50 175 -50 175 P 2 1 0 0 -50 175 -50 200 P 2 1 0 0 -50 200 -50 225 P 2 1 0 0 -50 225 50 225 P 2 1 0 0 -50 325 -50 300 P 2 1 0 0 -50 300 -50 275 P 2 1 0 0 -50 275 50 275 P 2 1 0 0 50 275 50 300 P 2 1 0 0 50 300 50 325 P 2 1 0 0 50 325 -50 325 P 2 1 0 0 -100 450 -200 450 P 2 1 0 0 -200 450 -200 400 P 2 1 0 0 -87 550 -62 550 P 2 1 0 0 -87 450 -62 450 P 2 1 0 0 -75 562 -75 537 P 2 1 0 0 100 500 175 500 P 2 1 0 0 175 500 300 500 P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 -300 P 2 1 0 0 300 -300 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 600 P 2 1 0 0 -300 600 -300 400 P 2 1 0 0 -300 400 -300 0 P 2 1 0 0 -300 0 -300 -200 P 2 1 0 0 -300 -200 -300 -700 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 50 75 50 100 P 2 1 0 0 50 100 50 125 P 2 1 0 0 50 125 -50 125 P 2 1 0 0 -50 125 -50 100 P 2 1 0 0 -50 100 -50 75 P 2 1 0 0 -50 75 50 75 P 2 1 0 0 -50 -325 -50 -300 P 2 1 0 0 -50 -300 -50 -275 P 2 1 0 0 -50 -275 50 -275 P 2 1 0 0 50 -275 50 -300 P 2 1 0 0 50 -300 50 -325 P 2 1 0 0 50 -325 -50 -325 P 2 1 0 0 -100 -50 -200 -50 P 2 1 0 0 -200 -50 -200 0 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -100 175 -100 P 2 1 0 0 -300 600 -150 600 P 2 1 0 0 -150 600 -150 550 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 175 500 175 300 P 2 1 0 0 175 300 50 300 P 2 1 0 0 -200 400 -200 300 P 2 1 0 0 -200 300 -50 300 P 2 1 0 0 -150 -150 -150 -200 P 2 1 0 0 -150 -200 -300 -200 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -200 200 -50 200 P 2 1 0 0 -200 300 -200 200 P 2 1 0 0 50 200 175 200 P 2 1 0 0 175 200 175 -100 P 2 1 0 0 50 100 162 100 P 2 1 0 0 -50 100 -200 100 P 2 1 0 0 -200 100 -200 0 P 2 1 0 0 -200 -50 -200 -300 P 2 1 0 0 50 -300 300 -300 P 2 1 0 0 -200 -300 -50 -300 C -200 400 12 1 1 0 N C -200 300 12 1 1 0 N C -200 0 12 1 1 0 N C -200 -50 12 1 1 0 N C 175 100 12 1 1 0 N C 175 500 12 1 1 0 N X +IN 3 -500 600 200 R 40 40 1 1 I X -IN 2 -500 -200 200 R 40 40 1 1 I X OUT 6 500 500 200 L 40 40 1 1 O X REF 5 500 -300 200 L 40 40 1 1 P X RG 1 -500 400 200 R 40 40 1 1 P X RG@1 8 -500 0 200 R 40 40 1 1 P X V+ 7 500 -400 200 L 40 40 1 1 W X V- 4 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA125P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA125P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA125 F0 "IC" -500 1125 50 H V L B F1 "INA125P" -500 -1500 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -100 -300 -100 -250 P 2 1 0 0 -100 -250 -100 -150 P 2 1 0 0 -100 -150 -100 -100 P 2 1 0 0 -100 -100 100 -200 P 2 1 0 0 100 -200 -100 -300 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 50 -475 50 -500 P 2 1 0 0 50 -500 50 -525 P 2 1 0 0 50 -525 -50 -525 P 2 1 0 0 -50 -525 -50 -500 P 2 1 0 0 -50 -500 -50 -475 P 2 1 0 0 -50 -475 50 -475 P 2 1 0 0 -50 -375 -50 -400 P 2 1 0 0 -50 -400 -50 -425 P 2 1 0 0 -50 -425 50 -425 P 2 1 0 0 50 -425 50 -400 P 2 1 0 0 50 -400 50 -375 P 2 1 0 0 50 -375 -50 -375 P 2 1 0 0 -100 -250 -200 -250 P 2 1 0 0 -200 -250 -200 -300 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -87 -250 -62 -250 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -200 300 -200 P 2 1 0 0 -500 -1400 300 -1400 P 2 1 0 0 300 -1400 300 -1000 P 2 1 0 0 300 -1000 300 -400 P 2 1 0 0 300 -400 300 1100 P 2 1 0 0 300 1100 -500 1100 P 2 1 0 0 -500 -100 -500 -300 P 2 1 0 0 -500 -300 -500 -700 P 2 1 0 0 -500 -700 -500 -900 P 2 1 0 0 -500 -900 -500 -1400 P 2 1 0 0 -100 -900 -100 -850 P 2 1 0 0 -100 -850 -100 -750 P 2 1 0 0 -100 -750 -100 -700 P 2 1 0 0 -100 -700 100 -800 P 2 1 0 0 100 -800 -100 -900 P 2 1 0 0 50 -625 50 -600 P 2 1 0 0 50 -600 50 -575 P 2 1 0 0 50 -575 -50 -575 P 2 1 0 0 -50 -575 -50 -600 P 2 1 0 0 -50 -600 -50 -625 P 2 1 0 0 -50 -625 50 -625 P 2 1 0 0 -50 -1025 -50 -1000 P 2 1 0 0 -50 -1000 -50 -975 P 2 1 0 0 -50 -975 50 -975 P 2 1 0 0 50 -975 50 -1000 P 2 1 0 0 50 -1000 50 -1025 P 2 1 0 0 50 -1025 -50 -1025 P 2 1 0 0 -100 -750 -200 -750 P 2 1 0 0 -200 -750 -200 -700 P 2 1 0 0 -100 -850 -150 -850 P 2 1 0 0 -87 -750 -62 -750 P 2 1 0 0 -87 -850 -62 -850 P 2 1 0 0 -75 -837 -75 -862 P 2 1 0 0 100 -800 175 -800 P 2 1 0 0 -500 -100 -150 -100 P 2 1 0 0 -150 -100 -150 -150 P 2 1 0 0 -500 -300 -200 -300 P 2 1 0 0 -200 -300 -200 -400 P 2 1 0 0 -200 -400 -50 -400 P 2 1 0 0 -150 -850 -150 -900 P 2 1 0 0 -150 -900 -500 -900 P 2 1 0 0 -500 -700 -200 -700 P 2 1 0 0 -200 -500 -50 -500 P 2 1 0 0 -200 -400 -200 -500 P 2 1 0 0 50 -500 175 -500 P 2 1 0 0 175 -500 175 -800 P 2 1 0 0 50 -600 162 -600 P 2 1 0 0 -50 -600 -200 -600 P 2 1 0 0 -200 -600 -200 -700 P 2 1 0 0 -200 -750 -200 -1000 P 2 1 0 0 50 -1000 300 -1000 P 2 1 0 0 -200 -1000 -50 -1000 P 2 1 0 0 -100 200 -100 150 P 2 1 0 0 -100 150 -100 50 P 2 1 0 0 -100 50 -100 0 P 2 1 0 0 -100 0 100 100 P 2 1 0 0 100 100 -100 200 P 2 1 0 0 -100 150 -200 150 P 2 1 0 0 -87 50 -62 50 P 2 1 0 0 -87 150 -62 150 P 2 1 0 0 -75 37 -75 62 P 2 1 0 0 125 250 100 250 P 2 1 0 0 100 250 75 250 P 2 1 0 0 75 250 75 350 P 2 1 0 0 75 350 100 350 P 2 1 0 0 100 350 125 350 P 2 1 0 0 125 350 125 250 P 2 1 0 0 125 450 100 450 P 2 1 0 0 100 450 75 450 P 2 1 0 0 75 450 75 550 P 2 1 0 0 75 550 100 550 P 2 1 0 0 100 550 125 550 P 2 1 0 0 125 550 125 450 P 2 1 0 0 125 650 100 650 P 2 1 0 0 100 650 75 650 P 2 1 0 0 75 650 75 750 P 2 1 0 0 75 750 100 750 P 2 1 0 0 100 750 125 750 P 2 1 0 0 125 750 125 650 P 2 1 0 0 125 850 75 850 P 2 1 0 0 75 850 75 950 P 2 1 0 0 75 950 100 950 P 2 1 0 0 100 950 125 950 P 2 1 0 0 125 950 125 850 P 2 1 0 0 100 200 300 200 P 2 1 0 0 100 400 300 400 P 2 1 0 0 100 600 300 600 P 2 1 0 0 100 800 300 800 P 2 1 0 0 -300 50 -300 1000 P 2 1 0 0 -300 1000 100 1000 P 2 1 0 0 100 1000 300 1000 P 2 1 0 0 100 100 300 100 P 2 1 0 0 100 200 100 250 P 2 1 0 0 100 450 100 400 P 2 1 0 0 100 400 100 350 P 2 1 0 0 100 650 100 600 P 2 1 0 0 100 600 100 550 P 2 1 0 0 100 837 100 800 P 2 1 0 0 100 800 100 750 P 2 1 0 0 100 1000 100 950 P 2 1 0 0 -100 50 -300 50 P 2 1 0 0 100 800 -200 800 P 2 1 0 0 -200 800 -200 150 P 2 1 0 0 50 -400 300 -400 P 2 1 0 0 -500 1100 -500 -100 C -200 -300 12 1 1 0 N C -200 -400 12 1 1 0 N C -200 -700 12 1 1 0 N C -200 -750 12 1 1 0 N C 175 -600 12 1 1 0 N C 100 1000 12 1 1 0 N C 100 800 12 1 1 0 N C 100 600 12 1 1 0 N C 100 400 12 1 1 0 N X +IN 6 -700 -100 200 R 40 40 1 1 I X -IN 7 -700 -900 200 R 40 40 1 1 I X OUT 10 500 -200 200 L 40 40 1 1 O X REF 5 500 -1000 200 L 40 40 1 1 P X REF2.5 14 500 600 200 L 40 40 1 1 O X REF5 15 500 400 200 L 40 40 1 1 O X REF10 16 500 200 200 L 40 40 1 1 O X REFBG 13 500 800 200 L 40 40 1 1 O X REFCOM 12 500 1000 200 L 40 40 1 1 P X REFOUT 4 500 100 200 L 40 40 1 1 O X RG 8 -700 -300 200 R 40 40 1 1 P X RG@1 9 -700 -700 200 R 40 40 1 1 P X SENSE 11 500 -400 200 L 40 40 1 1 P X SLEEP\ 2 -700 -1100 200 R 40 40 1 1 I X V+ 1 500 -1100 200 L 40 40 1 1 W X V- 3 500 -1300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA125U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA125U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA125 F0 "IC" -500 1125 50 H V L B F1 "INA125U" -500 -1500 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -100 -300 -100 -250 P 2 1 0 0 -100 -250 -100 -150 P 2 1 0 0 -100 -150 -100 -100 P 2 1 0 0 -100 -100 100 -200 P 2 1 0 0 100 -200 -100 -300 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 50 -475 50 -500 P 2 1 0 0 50 -500 50 -525 P 2 1 0 0 50 -525 -50 -525 P 2 1 0 0 -50 -525 -50 -500 P 2 1 0 0 -50 -500 -50 -475 P 2 1 0 0 -50 -475 50 -475 P 2 1 0 0 -50 -375 -50 -400 P 2 1 0 0 -50 -400 -50 -425 P 2 1 0 0 -50 -425 50 -425 P 2 1 0 0 50 -425 50 -400 P 2 1 0 0 50 -400 50 -375 P 2 1 0 0 50 -375 -50 -375 P 2 1 0 0 -100 -250 -200 -250 P 2 1 0 0 -200 -250 -200 -300 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -87 -250 -62 -250 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -200 300 -200 P 2 1 0 0 -500 -1400 300 -1400 P 2 1 0 0 300 -1400 300 -1000 P 2 1 0 0 300 -1000 300 -400 P 2 1 0 0 300 -400 300 1100 P 2 1 0 0 300 1100 -500 1100 P 2 1 0 0 -500 -100 -500 -300 P 2 1 0 0 -500 -300 -500 -700 P 2 1 0 0 -500 -700 -500 -900 P 2 1 0 0 -500 -900 -500 -1400 P 2 1 0 0 -100 -900 -100 -850 P 2 1 0 0 -100 -850 -100 -750 P 2 1 0 0 -100 -750 -100 -700 P 2 1 0 0 -100 -700 100 -800 P 2 1 0 0 100 -800 -100 -900 P 2 1 0 0 50 -625 50 -600 P 2 1 0 0 50 -600 50 -575 P 2 1 0 0 50 -575 -50 -575 P 2 1 0 0 -50 -575 -50 -600 P 2 1 0 0 -50 -600 -50 -625 P 2 1 0 0 -50 -625 50 -625 P 2 1 0 0 -50 -1025 -50 -1000 P 2 1 0 0 -50 -1000 -50 -975 P 2 1 0 0 -50 -975 50 -975 P 2 1 0 0 50 -975 50 -1000 P 2 1 0 0 50 -1000 50 -1025 P 2 1 0 0 50 -1025 -50 -1025 P 2 1 0 0 -100 -750 -200 -750 P 2 1 0 0 -200 -750 -200 -700 P 2 1 0 0 -100 -850 -150 -850 P 2 1 0 0 -87 -750 -62 -750 P 2 1 0 0 -87 -850 -62 -850 P 2 1 0 0 -75 -837 -75 -862 P 2 1 0 0 100 -800 175 -800 P 2 1 0 0 -500 -100 -150 -100 P 2 1 0 0 -150 -100 -150 -150 P 2 1 0 0 -500 -300 -200 -300 P 2 1 0 0 -200 -300 -200 -400 P 2 1 0 0 -200 -400 -50 -400 P 2 1 0 0 -150 -850 -150 -900 P 2 1 0 0 -150 -900 -500 -900 P 2 1 0 0 -500 -700 -200 -700 P 2 1 0 0 -200 -500 -50 -500 P 2 1 0 0 -200 -400 -200 -500 P 2 1 0 0 50 -500 175 -500 P 2 1 0 0 175 -500 175 -800 P 2 1 0 0 50 -600 162 -600 P 2 1 0 0 -50 -600 -200 -600 P 2 1 0 0 -200 -600 -200 -700 P 2 1 0 0 -200 -750 -200 -1000 P 2 1 0 0 50 -1000 300 -1000 P 2 1 0 0 -200 -1000 -50 -1000 P 2 1 0 0 -100 200 -100 150 P 2 1 0 0 -100 150 -100 50 P 2 1 0 0 -100 50 -100 0 P 2 1 0 0 -100 0 100 100 P 2 1 0 0 100 100 -100 200 P 2 1 0 0 -100 150 -200 150 P 2 1 0 0 -87 50 -62 50 P 2 1 0 0 -87 150 -62 150 P 2 1 0 0 -75 37 -75 62 P 2 1 0 0 125 250 100 250 P 2 1 0 0 100 250 75 250 P 2 1 0 0 75 250 75 350 P 2 1 0 0 75 350 100 350 P 2 1 0 0 100 350 125 350 P 2 1 0 0 125 350 125 250 P 2 1 0 0 125 450 100 450 P 2 1 0 0 100 450 75 450 P 2 1 0 0 75 450 75 550 P 2 1 0 0 75 550 100 550 P 2 1 0 0 100 550 125 550 P 2 1 0 0 125 550 125 450 P 2 1 0 0 125 650 100 650 P 2 1 0 0 100 650 75 650 P 2 1 0 0 75 650 75 750 P 2 1 0 0 75 750 100 750 P 2 1 0 0 100 750 125 750 P 2 1 0 0 125 750 125 650 P 2 1 0 0 125 850 75 850 P 2 1 0 0 75 850 75 950 P 2 1 0 0 75 950 100 950 P 2 1 0 0 100 950 125 950 P 2 1 0 0 125 950 125 850 P 2 1 0 0 100 200 300 200 P 2 1 0 0 100 400 300 400 P 2 1 0 0 100 600 300 600 P 2 1 0 0 100 800 300 800 P 2 1 0 0 -300 50 -300 1000 P 2 1 0 0 -300 1000 100 1000 P 2 1 0 0 100 1000 300 1000 P 2 1 0 0 100 100 300 100 P 2 1 0 0 100 200 100 250 P 2 1 0 0 100 450 100 400 P 2 1 0 0 100 400 100 350 P 2 1 0 0 100 650 100 600 P 2 1 0 0 100 600 100 550 P 2 1 0 0 100 837 100 800 P 2 1 0 0 100 800 100 750 P 2 1 0 0 100 1000 100 950 P 2 1 0 0 -100 50 -300 50 P 2 1 0 0 100 800 -200 800 P 2 1 0 0 -200 800 -200 150 P 2 1 0 0 50 -400 300 -400 P 2 1 0 0 -500 1100 -500 -100 C -200 -300 12 1 1 0 N C -200 -400 12 1 1 0 N C -200 -700 12 1 1 0 N C -200 -750 12 1 1 0 N C 175 -600 12 1 1 0 N C 100 1000 12 1 1 0 N C 100 800 12 1 1 0 N C 100 600 12 1 1 0 N C 100 400 12 1 1 0 N X +IN 6 -700 -100 200 R 40 40 1 1 I X -IN 7 -700 -900 200 R 40 40 1 1 I X OUT 10 500 -200 200 L 40 40 1 1 O X REF 5 500 -1000 200 L 40 40 1 1 P X REF2.5 14 500 600 200 L 40 40 1 1 O X REF5 15 500 400 200 L 40 40 1 1 O X REF10 16 500 200 200 L 40 40 1 1 O X REFBG 13 500 800 200 L 40 40 1 1 O X REFCOM 12 500 1000 200 L 40 40 1 1 P X REFOUT 4 500 100 200 L 40 40 1 1 O X RG 8 -700 -300 200 R 40 40 1 1 P X RG@1 9 -700 -700 200 R 40 40 1 1 P X SENSE 11 500 -400 200 L 40 40 1 1 P X SLEEP\ 2 -700 -1100 200 R 40 40 1 1 I X V+ 1 500 -1100 200 L 40 40 1 1 W X V- 3 500 -1300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA126E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA126E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA126 F0 "IC" -400 725 50 H V L B F1 "INA126E" -400 -800 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -100 400 -100 450 P 2 1 0 0 -100 450 -100 550 P 2 1 0 0 -100 550 -100 600 P 2 1 0 0 -100 600 100 500 P 2 1 0 0 100 500 -100 400 P 2 1 0 0 -100 550 -150 550 P 2 1 0 0 50 225 50 200 P 2 1 0 0 50 200 50 175 P 2 1 0 0 50 175 -50 175 P 2 1 0 0 -50 175 -50 200 P 2 1 0 0 -50 200 -50 225 P 2 1 0 0 -50 225 50 225 P 2 1 0 0 -50 325 -50 300 P 2 1 0 0 -50 300 -50 275 P 2 1 0 0 -50 275 50 275 P 2 1 0 0 50 275 50 300 P 2 1 0 0 50 300 50 325 P 2 1 0 0 50 325 -50 325 P 2 1 0 0 -100 450 -200 450 P 2 1 0 0 -200 450 -200 400 P 2 1 0 0 -87 550 -62 550 P 2 1 0 0 -87 450 -62 450 P 2 1 0 0 -75 562 -75 537 P 2 1 0 0 100 500 175 500 P 2 1 0 0 175 500 300 500 P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 -300 P 2 1 0 0 300 -300 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 600 P 2 1 0 0 -300 600 -300 400 P 2 1 0 0 -300 400 -300 0 P 2 1 0 0 -300 0 -300 -200 P 2 1 0 0 -300 -200 -300 -700 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 50 75 50 100 P 2 1 0 0 50 100 50 125 P 2 1 0 0 50 125 -50 125 P 2 1 0 0 -50 125 -50 100 P 2 1 0 0 -50 100 -50 75 P 2 1 0 0 -50 75 50 75 P 2 1 0 0 -50 -325 -50 -300 P 2 1 0 0 -50 -300 -50 -275 P 2 1 0 0 -50 -275 50 -275 P 2 1 0 0 50 -275 50 -300 P 2 1 0 0 50 -300 50 -325 P 2 1 0 0 50 -325 -50 -325 P 2 1 0 0 -100 -50 -200 -50 P 2 1 0 0 -200 -50 -200 0 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -100 175 -100 P 2 1 0 0 -300 600 -150 600 P 2 1 0 0 -150 600 -150 550 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 175 500 175 300 P 2 1 0 0 175 300 50 300 P 2 1 0 0 -200 400 -200 300 P 2 1 0 0 -200 300 -50 300 P 2 1 0 0 -150 -150 -150 -200 P 2 1 0 0 -150 -200 -300 -200 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -200 200 -50 200 P 2 1 0 0 -200 300 -200 200 P 2 1 0 0 50 200 175 200 P 2 1 0 0 175 200 175 -100 P 2 1 0 0 50 100 162 100 P 2 1 0 0 -50 100 -200 100 P 2 1 0 0 -200 100 -200 0 P 2 1 0 0 -200 -50 -200 -300 P 2 1 0 0 50 -300 300 -300 P 2 1 0 0 -200 -300 -50 -300 C -200 400 12 1 1 0 N C -200 300 12 1 1 0 N C -200 0 12 1 1 0 N C -200 -50 12 1 1 0 N C 175 100 12 1 1 0 N C 175 500 12 1 1 0 N X +IN 3 -500 600 200 R 40 40 1 1 I X -IN 2 -500 -200 200 R 40 40 1 1 I X OUT 6 500 500 200 L 40 40 1 1 O X REF 5 500 -300 200 L 40 40 1 1 P X RG 1 -500 400 200 R 40 40 1 1 P X RG@1 8 -500 0 200 R 40 40 1 1 P X V+ 7 500 -400 200 L 40 40 1 1 W X V- 4 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA126P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA126P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA126 F0 "IC" -400 725 50 H V L B F1 "INA126P" -400 -800 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -100 400 -100 450 P 2 1 0 0 -100 450 -100 550 P 2 1 0 0 -100 550 -100 600 P 2 1 0 0 -100 600 100 500 P 2 1 0 0 100 500 -100 400 P 2 1 0 0 -100 550 -150 550 P 2 1 0 0 50 225 50 200 P 2 1 0 0 50 200 50 175 P 2 1 0 0 50 175 -50 175 P 2 1 0 0 -50 175 -50 200 P 2 1 0 0 -50 200 -50 225 P 2 1 0 0 -50 225 50 225 P 2 1 0 0 -50 325 -50 300 P 2 1 0 0 -50 300 -50 275 P 2 1 0 0 -50 275 50 275 P 2 1 0 0 50 275 50 300 P 2 1 0 0 50 300 50 325 P 2 1 0 0 50 325 -50 325 P 2 1 0 0 -100 450 -200 450 P 2 1 0 0 -200 450 -200 400 P 2 1 0 0 -87 550 -62 550 P 2 1 0 0 -87 450 -62 450 P 2 1 0 0 -75 562 -75 537 P 2 1 0 0 100 500 175 500 P 2 1 0 0 175 500 300 500 P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 -300 P 2 1 0 0 300 -300 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 600 P 2 1 0 0 -300 600 -300 400 P 2 1 0 0 -300 400 -300 0 P 2 1 0 0 -300 0 -300 -200 P 2 1 0 0 -300 -200 -300 -700 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 50 75 50 100 P 2 1 0 0 50 100 50 125 P 2 1 0 0 50 125 -50 125 P 2 1 0 0 -50 125 -50 100 P 2 1 0 0 -50 100 -50 75 P 2 1 0 0 -50 75 50 75 P 2 1 0 0 -50 -325 -50 -300 P 2 1 0 0 -50 -300 -50 -275 P 2 1 0 0 -50 -275 50 -275 P 2 1 0 0 50 -275 50 -300 P 2 1 0 0 50 -300 50 -325 P 2 1 0 0 50 -325 -50 -325 P 2 1 0 0 -100 -50 -200 -50 P 2 1 0 0 -200 -50 -200 0 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -100 175 -100 P 2 1 0 0 -300 600 -150 600 P 2 1 0 0 -150 600 -150 550 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 175 500 175 300 P 2 1 0 0 175 300 50 300 P 2 1 0 0 -200 400 -200 300 P 2 1 0 0 -200 300 -50 300 P 2 1 0 0 -150 -150 -150 -200 P 2 1 0 0 -150 -200 -300 -200 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -200 200 -50 200 P 2 1 0 0 -200 300 -200 200 P 2 1 0 0 50 200 175 200 P 2 1 0 0 175 200 175 -100 P 2 1 0 0 50 100 162 100 P 2 1 0 0 -50 100 -200 100 P 2 1 0 0 -200 100 -200 0 P 2 1 0 0 -200 -50 -200 -300 P 2 1 0 0 50 -300 300 -300 P 2 1 0 0 -200 -300 -50 -300 C -200 400 12 1 1 0 N C -200 300 12 1 1 0 N C -200 0 12 1 1 0 N C -200 -50 12 1 1 0 N C 175 100 12 1 1 0 N C 175 500 12 1 1 0 N X +IN 3 -500 600 200 R 40 40 1 1 I X -IN 2 -500 -200 200 R 40 40 1 1 I X OUT 6 500 500 200 L 40 40 1 1 O X REF 5 500 -300 200 L 40 40 1 1 P X RG 1 -500 400 200 R 40 40 1 1 P X RG@1 8 -500 0 200 R 40 40 1 1 P X V+ 7 500 -400 200 L 40 40 1 1 W X V- 4 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA126U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA126U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA126 F0 "IC" -400 725 50 H V L B F1 "INA126U" -400 -800 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -100 400 -100 450 P 2 1 0 0 -100 450 -100 550 P 2 1 0 0 -100 550 -100 600 P 2 1 0 0 -100 600 100 500 P 2 1 0 0 100 500 -100 400 P 2 1 0 0 -100 550 -150 550 P 2 1 0 0 50 225 50 200 P 2 1 0 0 50 200 50 175 P 2 1 0 0 50 175 -50 175 P 2 1 0 0 -50 175 -50 200 P 2 1 0 0 -50 200 -50 225 P 2 1 0 0 -50 225 50 225 P 2 1 0 0 -50 325 -50 300 P 2 1 0 0 -50 300 -50 275 P 2 1 0 0 -50 275 50 275 P 2 1 0 0 50 275 50 300 P 2 1 0 0 50 300 50 325 P 2 1 0 0 50 325 -50 325 P 2 1 0 0 -100 450 -200 450 P 2 1 0 0 -200 450 -200 400 P 2 1 0 0 -87 550 -62 550 P 2 1 0 0 -87 450 -62 450 P 2 1 0 0 -75 562 -75 537 P 2 1 0 0 100 500 175 500 P 2 1 0 0 175 500 300 500 P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 -300 P 2 1 0 0 300 -300 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 600 P 2 1 0 0 -300 600 -300 400 P 2 1 0 0 -300 400 -300 0 P 2 1 0 0 -300 0 -300 -200 P 2 1 0 0 -300 -200 -300 -700 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 50 75 50 100 P 2 1 0 0 50 100 50 125 P 2 1 0 0 50 125 -50 125 P 2 1 0 0 -50 125 -50 100 P 2 1 0 0 -50 100 -50 75 P 2 1 0 0 -50 75 50 75 P 2 1 0 0 -50 -325 -50 -300 P 2 1 0 0 -50 -300 -50 -275 P 2 1 0 0 -50 -275 50 -275 P 2 1 0 0 50 -275 50 -300 P 2 1 0 0 50 -300 50 -325 P 2 1 0 0 50 -325 -50 -325 P 2 1 0 0 -100 -50 -200 -50 P 2 1 0 0 -200 -50 -200 0 P 2 1 0 0 -100 -150 -150 -150 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -137 -75 -162 P 2 1 0 0 100 -100 175 -100 P 2 1 0 0 -300 600 -150 600 P 2 1 0 0 -150 600 -150 550 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 175 500 175 300 P 2 1 0 0 175 300 50 300 P 2 1 0 0 -200 400 -200 300 P 2 1 0 0 -200 300 -50 300 P 2 1 0 0 -150 -150 -150 -200 P 2 1 0 0 -150 -200 -300 -200 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -200 200 -50 200 P 2 1 0 0 -200 300 -200 200 P 2 1 0 0 50 200 175 200 P 2 1 0 0 175 200 175 -100 P 2 1 0 0 50 100 162 100 P 2 1 0 0 -50 100 -200 100 P 2 1 0 0 -200 100 -200 0 P 2 1 0 0 -200 -50 -200 -300 P 2 1 0 0 50 -300 300 -300 P 2 1 0 0 -200 -300 -50 -300 C -200 400 12 1 1 0 N C -200 300 12 1 1 0 N C -200 0 12 1 1 0 N C -200 -50 12 1 1 0 N C 175 100 12 1 1 0 N C 175 500 12 1 1 0 N X +IN 3 -500 600 200 R 40 40 1 1 I X -IN 2 -500 -200 200 R 40 40 1 1 I X OUT 6 500 500 200 L 40 40 1 1 O X REF 5 500 -300 200 L 40 40 1 1 P X RG 1 -500 400 200 R 40 40 1 1 P X RG@1 8 -500 0 200 R 40 40 1 1 P X V+ 7 500 -400 200 L 40 40 1 1 W X V- 4 500 -600 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA128P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA128P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA128 F0 "IC" -400 525 50 H V L B F1 "INA128P" -400 -700 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 200 -300 250 P 2 1 0 0 -300 250 -300 350 P 2 1 0 0 -300 350 -300 400 P 2 1 0 0 -300 400 -100 300 P 2 1 0 0 -100 300 -300 200 P 2 1 0 0 -100 75 -100 100 P 2 1 0 0 -100 100 -100 125 P 2 1 0 0 -100 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -100 75 P 2 1 0 0 0 275 0 300 P 2 1 0 0 0 300 0 325 P 2 1 0 0 0 325 100 325 P 2 1 0 0 100 325 100 300 P 2 1 0 0 100 300 100 275 P 2 1 0 0 100 275 0 275 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 300 325 300 300 P 2 1 0 0 300 300 300 275 P 2 1 0 0 300 275 200 275 P 2 1 0 0 200 275 200 300 P 2 1 0 0 200 300 200 325 P 2 1 0 0 200 325 300 325 P 2 1 0 0 200 -175 200 -200 P 2 1 0 0 200 -200 200 -225 P 2 1 0 0 200 -225 300 -225 P 2 1 0 0 300 -225 300 -200 P 2 1 0 0 300 -200 300 -175 P 2 1 0 0 300 -175 200 -175 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -275 362 -275 337 P 2 1 0 0 -400 -600 500 -600 P 2 1 0 0 500 -600 500 -200 P 2 1 0 0 500 -200 500 100 P 2 1 0 0 500 100 500 500 P 2 1 0 0 500 500 -400 500 P 2 1 0 0 -400 500 -400 400 P 2 1 0 0 -400 400 -400 200 P 2 1 0 0 -400 200 -400 -100 P 2 1 0 0 -400 -100 -400 -300 P 2 1 0 0 -400 -300 -400 -600 P 2 1 0 0 -300 -300 -300 -250 P 2 1 0 0 -300 -250 -300 -150 P 2 1 0 0 -300 -150 -300 -100 P 2 1 0 0 -300 -100 -100 -200 P 2 1 0 0 -100 -200 -300 -300 P 2 1 0 0 100 -225 100 -200 P 2 1 0 0 100 -200 100 -175 P 2 1 0 0 100 -175 0 -175 P 2 1 0 0 0 -175 0 -200 P 2 1 0 0 0 -200 0 -225 P 2 1 0 0 0 -225 100 -225 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -300 -250 -350 -250 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -287 -250 -262 -250 P 2 1 0 0 -275 -237 -275 -262 P 2 1 0 0 -350 350 -350 400 P 2 1 0 0 -350 400 -400 400 P 2 1 0 0 -350 250 -350 200 P 2 1 0 0 -350 200 -400 200 P 2 1 0 0 200 0 200 50 P 2 1 0 0 200 50 200 150 P 2 1 0 0 200 150 200 200 P 2 1 0 0 200 200 400 100 P 2 1 0 0 400 100 200 0 P 2 1 0 0 200 50 150 50 P 2 1 0 0 212 150 237 150 P 2 1 0 0 212 50 237 50 P 2 1 0 0 225 62 225 37 P 2 1 0 0 -100 300 -50 300 P 2 1 0 0 -50 300 0 300 P 2 1 0 0 100 300 150 300 P 2 1 0 0 150 300 200 300 P 2 1 0 0 400 100 437 100 P 2 1 0 0 437 100 437 300 P 2 1 0 0 437 300 300 300 P 2 1 0 0 437 100 500 100 P 2 1 0 0 -350 200 -350 100 P 2 1 0 0 -350 100 -200 100 P 2 1 0 0 -50 300 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 150 300 150 150 P 2 1 0 0 150 150 200 150 P 2 1 0 0 -200 0 -350 0 P 2 1 0 0 -350 0 -350 -100 P 2 1 0 0 -350 -100 -350 -150 P 2 1 0 0 -100 0 -50 0 P 2 1 0 0 -50 0 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 0 -200 P 2 1 0 0 100 -200 150 -200 P 2 1 0 0 150 -200 200 -200 P 2 1 0 0 -350 -250 -350 -300 P 2 1 0 0 -350 -300 -400 -300 P 2 1 0 0 -400 -100 -350 -100 P 2 1 0 0 150 50 150 -200 P 2 1 0 0 300 -200 500 -200 C -350 200 12 1 1 0 N C -50 300 12 1 1 0 N C 150 300 12 1 1 0 N C 437 100 12 1 1 0 N C -350 -100 12 1 1 0 N C -50 -200 12 1 1 0 N C 150 -200 12 1 1 0 N X +IN 3 -600 -300 200 R 40 40 1 1 I X -IN 2 -600 400 200 R 40 40 1 1 I X OUT 6 700 100 200 L 40 40 1 1 O X REF 5 700 -200 200 L 40 40 1 1 P X RG 1 -600 200 200 R 40 40 1 1 P X RG@1 8 -600 -100 200 R 40 40 1 1 P X V+ 7 700 -300 200 L 40 40 1 1 W X V- 4 700 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA128U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA128U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA128 F0 "IC" -400 525 50 H V L B F1 "INA128U" -400 -700 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 200 -300 250 P 2 1 0 0 -300 250 -300 350 P 2 1 0 0 -300 350 -300 400 P 2 1 0 0 -300 400 -100 300 P 2 1 0 0 -100 300 -300 200 P 2 1 0 0 -100 75 -100 100 P 2 1 0 0 -100 100 -100 125 P 2 1 0 0 -100 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -100 75 P 2 1 0 0 0 275 0 300 P 2 1 0 0 0 300 0 325 P 2 1 0 0 0 325 100 325 P 2 1 0 0 100 325 100 300 P 2 1 0 0 100 300 100 275 P 2 1 0 0 100 275 0 275 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 300 325 300 300 P 2 1 0 0 300 300 300 275 P 2 1 0 0 300 275 200 275 P 2 1 0 0 200 275 200 300 P 2 1 0 0 200 300 200 325 P 2 1 0 0 200 325 300 325 P 2 1 0 0 200 -175 200 -200 P 2 1 0 0 200 -200 200 -225 P 2 1 0 0 200 -225 300 -225 P 2 1 0 0 300 -225 300 -200 P 2 1 0 0 300 -200 300 -175 P 2 1 0 0 300 -175 200 -175 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -275 362 -275 337 P 2 1 0 0 -400 -600 500 -600 P 2 1 0 0 500 -600 500 -200 P 2 1 0 0 500 -200 500 100 P 2 1 0 0 500 100 500 500 P 2 1 0 0 500 500 -400 500 P 2 1 0 0 -400 500 -400 400 P 2 1 0 0 -400 400 -400 200 P 2 1 0 0 -400 200 -400 -100 P 2 1 0 0 -400 -100 -400 -300 P 2 1 0 0 -400 -300 -400 -600 P 2 1 0 0 -300 -300 -300 -250 P 2 1 0 0 -300 -250 -300 -150 P 2 1 0 0 -300 -150 -300 -100 P 2 1 0 0 -300 -100 -100 -200 P 2 1 0 0 -100 -200 -300 -300 P 2 1 0 0 100 -225 100 -200 P 2 1 0 0 100 -200 100 -175 P 2 1 0 0 100 -175 0 -175 P 2 1 0 0 0 -175 0 -200 P 2 1 0 0 0 -200 0 -225 P 2 1 0 0 0 -225 100 -225 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -300 -250 -350 -250 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -287 -250 -262 -250 P 2 1 0 0 -275 -237 -275 -262 P 2 1 0 0 -350 350 -350 400 P 2 1 0 0 -350 400 -400 400 P 2 1 0 0 -350 250 -350 200 P 2 1 0 0 -350 200 -400 200 P 2 1 0 0 200 0 200 50 P 2 1 0 0 200 50 200 150 P 2 1 0 0 200 150 200 200 P 2 1 0 0 200 200 400 100 P 2 1 0 0 400 100 200 0 P 2 1 0 0 200 50 150 50 P 2 1 0 0 212 150 237 150 P 2 1 0 0 212 50 237 50 P 2 1 0 0 225 62 225 37 P 2 1 0 0 -100 300 -50 300 P 2 1 0 0 -50 300 0 300 P 2 1 0 0 100 300 150 300 P 2 1 0 0 150 300 200 300 P 2 1 0 0 400 100 437 100 P 2 1 0 0 437 100 437 300 P 2 1 0 0 437 300 300 300 P 2 1 0 0 437 100 500 100 P 2 1 0 0 -350 200 -350 100 P 2 1 0 0 -350 100 -200 100 P 2 1 0 0 -50 300 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 150 300 150 150 P 2 1 0 0 150 150 200 150 P 2 1 0 0 -200 0 -350 0 P 2 1 0 0 -350 0 -350 -100 P 2 1 0 0 -350 -100 -350 -150 P 2 1 0 0 -100 0 -50 0 P 2 1 0 0 -50 0 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 0 -200 P 2 1 0 0 100 -200 150 -200 P 2 1 0 0 150 -200 200 -200 P 2 1 0 0 -350 -250 -350 -300 P 2 1 0 0 -350 -300 -400 -300 P 2 1 0 0 -400 -100 -350 -100 P 2 1 0 0 150 50 150 -200 P 2 1 0 0 300 -200 500 -200 C -350 200 12 1 1 0 N C -50 300 12 1 1 0 N C 150 300 12 1 1 0 N C 437 100 12 1 1 0 N C -350 -100 12 1 1 0 N C -50 -200 12 1 1 0 N C 150 -200 12 1 1 0 N X +IN 3 -600 -300 200 R 40 40 1 1 I X -IN 2 -600 400 200 R 40 40 1 1 I X OUT 6 700 100 200 L 40 40 1 1 O X REF 5 700 -200 200 L 40 40 1 1 P X RG 1 -600 200 200 R 40 40 1 1 P X RG@1 8 -600 -100 200 R 40 40 1 1 P X V+ 7 700 -300 200 L 40 40 1 1 W X V- 4 700 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA129P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA129P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA128 F0 "IC" -400 525 50 H V L B F1 "INA129P" -400 -700 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 200 -300 250 P 2 1 0 0 -300 250 -300 350 P 2 1 0 0 -300 350 -300 400 P 2 1 0 0 -300 400 -100 300 P 2 1 0 0 -100 300 -300 200 P 2 1 0 0 -100 75 -100 100 P 2 1 0 0 -100 100 -100 125 P 2 1 0 0 -100 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -100 75 P 2 1 0 0 0 275 0 300 P 2 1 0 0 0 300 0 325 P 2 1 0 0 0 325 100 325 P 2 1 0 0 100 325 100 300 P 2 1 0 0 100 300 100 275 P 2 1 0 0 100 275 0 275 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 300 325 300 300 P 2 1 0 0 300 300 300 275 P 2 1 0 0 300 275 200 275 P 2 1 0 0 200 275 200 300 P 2 1 0 0 200 300 200 325 P 2 1 0 0 200 325 300 325 P 2 1 0 0 200 -175 200 -200 P 2 1 0 0 200 -200 200 -225 P 2 1 0 0 200 -225 300 -225 P 2 1 0 0 300 -225 300 -200 P 2 1 0 0 300 -200 300 -175 P 2 1 0 0 300 -175 200 -175 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -275 362 -275 337 P 2 1 0 0 -400 -600 500 -600 P 2 1 0 0 500 -600 500 -200 P 2 1 0 0 500 -200 500 100 P 2 1 0 0 500 100 500 500 P 2 1 0 0 500 500 -400 500 P 2 1 0 0 -400 500 -400 400 P 2 1 0 0 -400 400 -400 200 P 2 1 0 0 -400 200 -400 -100 P 2 1 0 0 -400 -100 -400 -300 P 2 1 0 0 -400 -300 -400 -600 P 2 1 0 0 -300 -300 -300 -250 P 2 1 0 0 -300 -250 -300 -150 P 2 1 0 0 -300 -150 -300 -100 P 2 1 0 0 -300 -100 -100 -200 P 2 1 0 0 -100 -200 -300 -300 P 2 1 0 0 100 -225 100 -200 P 2 1 0 0 100 -200 100 -175 P 2 1 0 0 100 -175 0 -175 P 2 1 0 0 0 -175 0 -200 P 2 1 0 0 0 -200 0 -225 P 2 1 0 0 0 -225 100 -225 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -300 -250 -350 -250 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -287 -250 -262 -250 P 2 1 0 0 -275 -237 -275 -262 P 2 1 0 0 -350 350 -350 400 P 2 1 0 0 -350 400 -400 400 P 2 1 0 0 -350 250 -350 200 P 2 1 0 0 -350 200 -400 200 P 2 1 0 0 200 0 200 50 P 2 1 0 0 200 50 200 150 P 2 1 0 0 200 150 200 200 P 2 1 0 0 200 200 400 100 P 2 1 0 0 400 100 200 0 P 2 1 0 0 200 50 150 50 P 2 1 0 0 212 150 237 150 P 2 1 0 0 212 50 237 50 P 2 1 0 0 225 62 225 37 P 2 1 0 0 -100 300 -50 300 P 2 1 0 0 -50 300 0 300 P 2 1 0 0 100 300 150 300 P 2 1 0 0 150 300 200 300 P 2 1 0 0 400 100 437 100 P 2 1 0 0 437 100 437 300 P 2 1 0 0 437 300 300 300 P 2 1 0 0 437 100 500 100 P 2 1 0 0 -350 200 -350 100 P 2 1 0 0 -350 100 -200 100 P 2 1 0 0 -50 300 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 150 300 150 150 P 2 1 0 0 150 150 200 150 P 2 1 0 0 -200 0 -350 0 P 2 1 0 0 -350 0 -350 -100 P 2 1 0 0 -350 -100 -350 -150 P 2 1 0 0 -100 0 -50 0 P 2 1 0 0 -50 0 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 0 -200 P 2 1 0 0 100 -200 150 -200 P 2 1 0 0 150 -200 200 -200 P 2 1 0 0 -350 -250 -350 -300 P 2 1 0 0 -350 -300 -400 -300 P 2 1 0 0 -400 -100 -350 -100 P 2 1 0 0 150 50 150 -200 P 2 1 0 0 300 -200 500 -200 C -350 200 12 1 1 0 N C -50 300 12 1 1 0 N C 150 300 12 1 1 0 N C 437 100 12 1 1 0 N C -350 -100 12 1 1 0 N C -50 -200 12 1 1 0 N C 150 -200 12 1 1 0 N X +IN 3 -600 -300 200 R 40 40 1 1 I X -IN 2 -600 400 200 R 40 40 1 1 I X OUT 6 700 100 200 L 40 40 1 1 O X REF 5 700 -200 200 L 40 40 1 1 P X RG 1 -600 200 200 R 40 40 1 1 P X RG@1 8 -600 -100 200 R 40 40 1 1 P X V+ 7 700 -300 200 L 40 40 1 1 W X V- 4 700 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA129U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA129U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA128 F0 "IC" -400 525 50 H V L B F1 "INA129U" -400 -700 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 200 -300 250 P 2 1 0 0 -300 250 -300 350 P 2 1 0 0 -300 350 -300 400 P 2 1 0 0 -300 400 -100 300 P 2 1 0 0 -100 300 -300 200 P 2 1 0 0 -100 75 -100 100 P 2 1 0 0 -100 100 -100 125 P 2 1 0 0 -100 125 -200 125 P 2 1 0 0 -200 125 -200 100 P 2 1 0 0 -200 100 -200 75 P 2 1 0 0 -200 75 -100 75 P 2 1 0 0 0 275 0 300 P 2 1 0 0 0 300 0 325 P 2 1 0 0 0 325 100 325 P 2 1 0 0 100 325 100 300 P 2 1 0 0 100 300 100 275 P 2 1 0 0 100 275 0 275 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 300 325 300 300 P 2 1 0 0 300 300 300 275 P 2 1 0 0 300 275 200 275 P 2 1 0 0 200 275 200 300 P 2 1 0 0 200 300 200 325 P 2 1 0 0 200 325 300 325 P 2 1 0 0 200 -175 200 -200 P 2 1 0 0 200 -200 200 -225 P 2 1 0 0 200 -225 300 -225 P 2 1 0 0 300 -225 300 -200 P 2 1 0 0 300 -200 300 -175 P 2 1 0 0 300 -175 200 -175 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -275 362 -275 337 P 2 1 0 0 -400 -600 500 -600 P 2 1 0 0 500 -600 500 -200 P 2 1 0 0 500 -200 500 100 P 2 1 0 0 500 100 500 500 P 2 1 0 0 500 500 -400 500 P 2 1 0 0 -400 500 -400 400 P 2 1 0 0 -400 400 -400 200 P 2 1 0 0 -400 200 -400 -100 P 2 1 0 0 -400 -100 -400 -300 P 2 1 0 0 -400 -300 -400 -600 P 2 1 0 0 -300 -300 -300 -250 P 2 1 0 0 -300 -250 -300 -150 P 2 1 0 0 -300 -150 -300 -100 P 2 1 0 0 -300 -100 -100 -200 P 2 1 0 0 -100 -200 -300 -300 P 2 1 0 0 100 -225 100 -200 P 2 1 0 0 100 -200 100 -175 P 2 1 0 0 100 -175 0 -175 P 2 1 0 0 0 -175 0 -200 P 2 1 0 0 0 -200 0 -225 P 2 1 0 0 0 -225 100 -225 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -300 -250 -350 -250 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -287 -250 -262 -250 P 2 1 0 0 -275 -237 -275 -262 P 2 1 0 0 -350 350 -350 400 P 2 1 0 0 -350 400 -400 400 P 2 1 0 0 -350 250 -350 200 P 2 1 0 0 -350 200 -400 200 P 2 1 0 0 200 0 200 50 P 2 1 0 0 200 50 200 150 P 2 1 0 0 200 150 200 200 P 2 1 0 0 200 200 400 100 P 2 1 0 0 400 100 200 0 P 2 1 0 0 200 50 150 50 P 2 1 0 0 212 150 237 150 P 2 1 0 0 212 50 237 50 P 2 1 0 0 225 62 225 37 P 2 1 0 0 -100 300 -50 300 P 2 1 0 0 -50 300 0 300 P 2 1 0 0 100 300 150 300 P 2 1 0 0 150 300 200 300 P 2 1 0 0 400 100 437 100 P 2 1 0 0 437 100 437 300 P 2 1 0 0 437 300 300 300 P 2 1 0 0 437 100 500 100 P 2 1 0 0 -350 200 -350 100 P 2 1 0 0 -350 100 -200 100 P 2 1 0 0 -50 300 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 150 300 150 150 P 2 1 0 0 150 150 200 150 P 2 1 0 0 -200 0 -350 0 P 2 1 0 0 -350 0 -350 -100 P 2 1 0 0 -350 -100 -350 -150 P 2 1 0 0 -100 0 -50 0 P 2 1 0 0 -50 0 -50 -200 P 2 1 0 0 -50 -200 -100 -200 P 2 1 0 0 -50 -200 0 -200 P 2 1 0 0 100 -200 150 -200 P 2 1 0 0 150 -200 200 -200 P 2 1 0 0 -350 -250 -350 -300 P 2 1 0 0 -350 -300 -400 -300 P 2 1 0 0 -400 -100 -350 -100 P 2 1 0 0 150 50 150 -200 P 2 1 0 0 300 -200 500 -200 C -350 200 12 1 1 0 N C -50 300 12 1 1 0 N C 150 300 12 1 1 0 N C 437 100 12 1 1 0 N C -350 -100 12 1 1 0 N C -50 -200 12 1 1 0 N C 150 -200 12 1 1 0 N X +IN 3 -600 -300 200 R 40 40 1 1 I X -IN 2 -600 400 200 R 40 40 1 1 I X OUT 6 700 100 200 L 40 40 1 1 O X REF 5 700 -200 200 L 40 40 1 1 P X RG 1 -600 200 200 R 40 40 1 1 P X RG@1 8 -600 -100 200 R 40 40 1 1 P X V+ 7 700 -300 200 L 40 40 1 1 W X V- 4 700 -500 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA132P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA132P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA132P" -500 -500 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA132U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA132U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA132U" -500 -500 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA134P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA134P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA134P" -500 -500 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA134U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA134U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA134U" -500 -500 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA137P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA137P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA137P" -500 -500 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA137U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA137U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA134 F0 "IC" -500 525 50 H V L B F1 "INA137U" -500 -500 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 0 100 0 150 P 2 1 0 0 0 150 0 250 P 2 1 0 0 0 250 0 300 P 2 1 0 0 0 300 200 200 P 2 1 0 0 200 200 0 100 P 2 1 0 0 -100 375 -100 400 P 2 1 0 0 -100 400 -100 425 P 2 1 0 0 -100 425 -200 425 P 2 1 0 0 -200 425 -200 400 P 2 1 0 0 -200 400 -200 375 P 2 1 0 0 -200 375 -100 375 P 2 1 0 0 100 375 100 400 P 2 1 0 0 100 400 100 425 P 2 1 0 0 100 425 200 425 P 2 1 0 0 200 425 200 400 P 2 1 0 0 200 400 200 375 P 2 1 0 0 200 375 100 375 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -100 25 -100 0 P 2 1 0 0 -100 0 -100 -25 P 2 1 0 0 -100 -25 -200 -25 P 2 1 0 0 -200 -25 -200 0 P 2 1 0 0 -200 0 -200 25 P 2 1 0 0 -200 25 -100 25 P 2 1 0 0 100 25 100 0 P 2 1 0 0 100 0 100 -25 P 2 1 0 0 100 -25 200 -25 P 2 1 0 0 200 -25 200 0 P 2 1 0 0 200 0 200 25 P 2 1 0 0 200 25 100 25 P 2 1 0 0 -50 250 -50 400 P 2 1 0 0 -50 400 -100 400 P 2 1 0 0 -50 400 100 400 P 2 1 0 0 0 150 -50 150 P 2 1 0 0 -50 150 -50 0 P 2 1 0 0 -50 0 -100 0 P 2 1 0 0 -50 0 100 0 P 2 1 0 0 12 250 37 250 P 2 1 0 0 12 150 37 150 P 2 1 0 0 25 162 25 137 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 300 400 200 400 P 2 1 0 0 200 200 300 200 P 2 1 0 0 300 0 200 0 P 2 1 0 0 -300 0 -200 0 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 500 P 2 1 0 0 300 500 -300 500 P 2 1 0 0 -300 500 -300 -400 C -50 400 12 1 1 0 N C -50 0 12 1 1 0 N X +IN 3 -500 0 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X NC 8 -500 -300 200 R 40 40 1 1 U X OUT 6 500 200 200 L 40 40 1 1 O X REF 1 500 0 200 L 40 40 1 1 P X SENSE 5 500 400 200 L 40 40 1 1 P X V+ 7 500 -100 200 L 40 40 1 1 W X V- 4 500 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA138 # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA138 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA138 F0 "IC" -300 425 50 H V L B F1 "INA138" -300 -500 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -50 -200 -50 -100 P 2 1 0 0 -50 -100 -50 100 P 2 1 0 0 -50 100 -50 200 P 2 1 0 0 -50 200 150 0 P 2 1 0 0 150 0 -50 -200 P 2 1 0 0 -150 75 -150 100 P 2 1 0 0 -150 100 -150 125 P 2 1 0 0 -150 125 -250 125 P 2 1 0 0 -250 125 -250 100 P 2 1 0 0 -250 100 -250 75 P 2 1 0 0 -250 75 -150 75 P 2 1 0 0 -150 -75 -150 -100 P 2 1 0 0 -150 -100 -150 -125 P 2 1 0 0 -150 -125 -250 -125 P 2 1 0 0 -250 -125 -250 -100 P 2 1 0 0 -250 -100 -250 -75 P 2 1 0 0 -250 -75 -150 -75 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -100 100 -150 100 P 2 1 0 0 -50 -100 -150 -100 P 2 1 0 0 -17 100 7 100 P 2 1 0 0 -17 -100 7 -100 P 2 1 0 0 -5 -87 -5 -112 P 2 1 0 0 -300 100 -250 100 P 2 1 0 0 -300 -100 -250 -100 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 -100 P 2 1 0 0 300 -100 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -400 P 2 1 0 0 250 50 250 250 P 2 1 0 0 250 250 -100 250 P 2 1 0 0 -100 250 -100 100 P 2 1 0 0 250 -50 240 -40 P 2 1 0 0 240 -40 200 0 P 2 1 0 0 200 0 250 50 P 2 1 0 0 150 0 200 0 P 2 1 0 0 250 -50 230 -10 P 2 1 0 0 230 -10 210 -30 P 2 1 0 0 210 -30 250 -50 P 2 1 0 0 230 -20 220 -30 P 2 1 0 0 220 -30 240 -40 P 2 1 0 0 240 -40 230 -20 P 2 1 0 0 250 -50 250 -100 P 2 1 0 0 250 -100 300 -100 S 190 -40 200 40 1 1 0 F C -100 100 12 1 1 0 N X IN+ 3 -400 -100 100 R 40 40 1 1 I X IN- 4 -400 100 100 R 40 40 1 1 I X OUT 1 400 -100 100 L 40 40 1 1 O X V+ 5 400 300 100 L 40 40 1 1 W X V- 2 400 -300 100 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA141P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA141P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA141 F0 "IC" -700 625 50 H V L B F1 "INA141P" -700 -600 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 300 -300 350 P 2 1 0 0 -300 350 -300 450 P 2 1 0 0 -300 450 -300 500 P 2 1 0 0 -300 500 -100 400 P 2 1 0 0 -100 400 -300 300 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 0 375 0 400 P 2 1 0 0 0 400 0 425 P 2 1 0 0 0 425 100 425 P 2 1 0 0 100 425 100 400 P 2 1 0 0 100 400 100 375 P 2 1 0 0 100 375 0 375 P 2 1 0 0 -300 450 -350 450 P 2 1 0 0 300 425 300 400 P 2 1 0 0 300 400 300 375 P 2 1 0 0 300 375 200 375 P 2 1 0 0 200 375 200 400 P 2 1 0 0 200 400 200 425 P 2 1 0 0 200 425 300 425 P 2 1 0 0 200 -75 200 -100 P 2 1 0 0 200 -100 200 -125 P 2 1 0 0 200 -125 300 -125 P 2 1 0 0 300 -125 300 -100 P 2 1 0 0 300 -100 300 -75 P 2 1 0 0 300 -75 200 -75 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 -287 450 -262 450 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -275 462 -275 437 P 2 1 0 0 -700 -500 500 -500 P 2 1 0 0 500 -500 500 -100 P 2 1 0 0 500 -100 500 200 P 2 1 0 0 500 200 500 600 P 2 1 0 0 500 600 -700 600 P 2 1 0 0 -700 600 -700 500 P 2 1 0 0 -700 500 -700 300 P 2 1 0 0 -700 300 -700 0 P 2 1 0 0 -700 0 -700 -200 P 2 1 0 0 -700 -200 -700 -500 P 2 1 0 0 -300 -200 -300 -150 P 2 1 0 0 -300 -150 -300 -50 P 2 1 0 0 -300 -50 -300 0 P 2 1 0 0 -300 0 -100 -100 P 2 1 0 0 -100 -100 -300 -200 P 2 1 0 0 100 -125 100 -100 P 2 1 0 0 100 -100 100 -75 P 2 1 0 0 100 -75 0 -75 P 2 1 0 0 0 -75 0 -100 P 2 1 0 0 0 -100 0 -125 P 2 1 0 0 0 -125 100 -125 P 2 1 0 0 -200 75 -200 100 P 2 1 0 0 -200 100 -200 125 P 2 1 0 0 -200 125 -100 125 P 2 1 0 0 -100 125 -100 100 P 2 1 0 0 -100 100 -100 75 P 2 1 0 0 -100 75 -200 75 P 2 1 0 0 -300 -50 -350 -50 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -287 -50 -262 -50 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -275 -137 -275 -162 P 2 1 0 0 -350 450 -350 500 P 2 1 0 0 -350 500 -700 500 P 2 1 0 0 200 100 200 150 P 2 1 0 0 200 150 200 250 P 2 1 0 0 200 250 200 300 P 2 1 0 0 200 300 400 200 P 2 1 0 0 400 200 200 100 P 2 1 0 0 200 150 150 150 P 2 1 0 0 212 250 237 250 P 2 1 0 0 212 150 237 150 P 2 1 0 0 225 162 225 137 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 0 400 P 2 1 0 0 100 400 150 400 P 2 1 0 0 150 400 200 400 P 2 1 0 0 400 200 437 200 P 2 1 0 0 437 200 437 400 P 2 1 0 0 437 400 300 400 P 2 1 0 0 437 200 500 200 P 2 1 0 0 -350 350 -350 300 P 2 1 0 0 -350 300 -350 200 P 2 1 0 0 -350 200 -200 200 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 150 400 150 250 P 2 1 0 0 150 250 200 250 P 2 1 0 0 -200 100 -350 100 P 2 1 0 0 -350 100 -350 -50 P 2 1 0 0 -100 100 -50 100 P 2 1 0 0 -50 100 -50 -100 P 2 1 0 0 -50 -100 -100 -100 P 2 1 0 0 -50 -100 0 -100 P 2 1 0 0 100 -100 150 -100 P 2 1 0 0 150 -100 200 -100 P 2 1 0 0 -350 -150 -350 -200 P 2 1 0 0 -350 -200 -700 -200 P 2 1 0 0 150 150 150 -100 P 2 1 0 0 300 -100 500 -100 P 2 1 0 0 -400 275 -400 300 P 2 1 0 0 -400 300 -400 325 P 2 1 0 0 -400 325 -500 325 P 2 1 0 0 -500 325 -500 300 P 2 1 0 0 -500 300 -500 275 P 2 1 0 0 -500 275 -400 275 P 2 1 0 0 -400 -25 -400 0 P 2 1 0 0 -400 0 -400 25 P 2 1 0 0 -400 25 -500 25 P 2 1 0 0 -500 25 -500 0 P 2 1 0 0 -500 0 -500 -25 P 2 1 0 0 -500 -25 -400 -25 P 2 1 0 0 -350 0 -400 0 P 2 1 0 0 -575 200 -600 200 P 2 1 0 0 -600 200 -625 200 P 2 1 0 0 -625 200 -625 100 P 2 1 0 0 -625 100 -600 100 P 2 1 0 0 -600 100 -575 100 P 2 1 0 0 -575 100 -575 200 P 2 1 0 0 -600 0 -600 100 P 2 1 0 0 -600 300 -600 200 P 2 1 0 0 -700 300 -600 300 P 2 1 0 0 -600 300 -500 300 P 2 1 0 0 -700 0 -600 0 P 2 1 0 0 -600 0 -500 0 P 2 1 0 0 -400 300 -350 300 C -350 300 12 1 1 0 N C -50 400 12 1 1 0 N C 150 400 12 1 1 0 N C 437 200 12 1 1 0 N C -350 0 12 1 1 0 N C -50 -100 12 1 1 0 N C 150 -100 12 1 1 0 N C -600 300 12 1 1 0 N C -600 0 12 1 1 0 N X +IN 3 -900 -200 200 R 40 40 1 1 I X -IN 2 -900 500 200 R 40 40 1 1 I X J 1 -900 300 200 R 40 40 1 1 P X J@1 8 -900 0 200 R 40 40 1 1 P X OUT 6 700 200 200 L 40 40 1 1 O X REF 5 -900 -400 200 R 40 40 1 1 P X V+ 7 700 -200 200 L 40 40 1 1 W X V- 4 700 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA141U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA141U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA141 F0 "IC" -700 625 50 H V L B F1 "INA141U" -700 -600 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 300 -300 350 P 2 1 0 0 -300 350 -300 450 P 2 1 0 0 -300 450 -300 500 P 2 1 0 0 -300 500 -100 400 P 2 1 0 0 -100 400 -300 300 P 2 1 0 0 -100 175 -100 200 P 2 1 0 0 -100 200 -100 225 P 2 1 0 0 -100 225 -200 225 P 2 1 0 0 -200 225 -200 200 P 2 1 0 0 -200 200 -200 175 P 2 1 0 0 -200 175 -100 175 P 2 1 0 0 0 375 0 400 P 2 1 0 0 0 400 0 425 P 2 1 0 0 0 425 100 425 P 2 1 0 0 100 425 100 400 P 2 1 0 0 100 400 100 375 P 2 1 0 0 100 375 0 375 P 2 1 0 0 -300 450 -350 450 P 2 1 0 0 300 425 300 400 P 2 1 0 0 300 400 300 375 P 2 1 0 0 300 375 200 375 P 2 1 0 0 200 375 200 400 P 2 1 0 0 200 400 200 425 P 2 1 0 0 200 425 300 425 P 2 1 0 0 200 -75 200 -100 P 2 1 0 0 200 -100 200 -125 P 2 1 0 0 200 -125 300 -125 P 2 1 0 0 300 -125 300 -100 P 2 1 0 0 300 -100 300 -75 P 2 1 0 0 300 -75 200 -75 P 2 1 0 0 -300 350 -350 350 P 2 1 0 0 -287 450 -262 450 P 2 1 0 0 -287 350 -262 350 P 2 1 0 0 -275 462 -275 437 P 2 1 0 0 -700 -500 500 -500 P 2 1 0 0 500 -500 500 -100 P 2 1 0 0 500 -100 500 200 P 2 1 0 0 500 200 500 600 P 2 1 0 0 500 600 -700 600 P 2 1 0 0 -700 600 -700 500 P 2 1 0 0 -700 500 -700 300 P 2 1 0 0 -700 300 -700 0 P 2 1 0 0 -700 0 -700 -200 P 2 1 0 0 -700 -200 -700 -500 P 2 1 0 0 -300 -200 -300 -150 P 2 1 0 0 -300 -150 -300 -50 P 2 1 0 0 -300 -50 -300 0 P 2 1 0 0 -300 0 -100 -100 P 2 1 0 0 -100 -100 -300 -200 P 2 1 0 0 100 -125 100 -100 P 2 1 0 0 100 -100 100 -75 P 2 1 0 0 100 -75 0 -75 P 2 1 0 0 0 -75 0 -100 P 2 1 0 0 0 -100 0 -125 P 2 1 0 0 0 -125 100 -125 P 2 1 0 0 -200 75 -200 100 P 2 1 0 0 -200 100 -200 125 P 2 1 0 0 -200 125 -100 125 P 2 1 0 0 -100 125 -100 100 P 2 1 0 0 -100 100 -100 75 P 2 1 0 0 -100 75 -200 75 P 2 1 0 0 -300 -50 -350 -50 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -287 -50 -262 -50 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -275 -137 -275 -162 P 2 1 0 0 -350 450 -350 500 P 2 1 0 0 -350 500 -700 500 P 2 1 0 0 200 100 200 150 P 2 1 0 0 200 150 200 250 P 2 1 0 0 200 250 200 300 P 2 1 0 0 200 300 400 200 P 2 1 0 0 400 200 200 100 P 2 1 0 0 200 150 150 150 P 2 1 0 0 212 250 237 250 P 2 1 0 0 212 150 237 150 P 2 1 0 0 225 162 225 137 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 0 400 P 2 1 0 0 100 400 150 400 P 2 1 0 0 150 400 200 400 P 2 1 0 0 400 200 437 200 P 2 1 0 0 437 200 437 400 P 2 1 0 0 437 400 300 400 P 2 1 0 0 437 200 500 200 P 2 1 0 0 -350 350 -350 300 P 2 1 0 0 -350 300 -350 200 P 2 1 0 0 -350 200 -200 200 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 150 400 150 250 P 2 1 0 0 150 250 200 250 P 2 1 0 0 -200 100 -350 100 P 2 1 0 0 -350 100 -350 -50 P 2 1 0 0 -100 100 -50 100 P 2 1 0 0 -50 100 -50 -100 P 2 1 0 0 -50 -100 -100 -100 P 2 1 0 0 -50 -100 0 -100 P 2 1 0 0 100 -100 150 -100 P 2 1 0 0 150 -100 200 -100 P 2 1 0 0 -350 -150 -350 -200 P 2 1 0 0 -350 -200 -700 -200 P 2 1 0 0 150 150 150 -100 P 2 1 0 0 300 -100 500 -100 P 2 1 0 0 -400 275 -400 300 P 2 1 0 0 -400 300 -400 325 P 2 1 0 0 -400 325 -500 325 P 2 1 0 0 -500 325 -500 300 P 2 1 0 0 -500 300 -500 275 P 2 1 0 0 -500 275 -400 275 P 2 1 0 0 -400 -25 -400 0 P 2 1 0 0 -400 0 -400 25 P 2 1 0 0 -400 25 -500 25 P 2 1 0 0 -500 25 -500 0 P 2 1 0 0 -500 0 -500 -25 P 2 1 0 0 -500 -25 -400 -25 P 2 1 0 0 -350 0 -400 0 P 2 1 0 0 -575 200 -600 200 P 2 1 0 0 -600 200 -625 200 P 2 1 0 0 -625 200 -625 100 P 2 1 0 0 -625 100 -600 100 P 2 1 0 0 -600 100 -575 100 P 2 1 0 0 -575 100 -575 200 P 2 1 0 0 -600 0 -600 100 P 2 1 0 0 -600 300 -600 200 P 2 1 0 0 -700 300 -600 300 P 2 1 0 0 -600 300 -500 300 P 2 1 0 0 -700 0 -600 0 P 2 1 0 0 -600 0 -500 0 P 2 1 0 0 -400 300 -350 300 C -350 300 12 1 1 0 N C -50 400 12 1 1 0 N C 150 400 12 1 1 0 N C 437 200 12 1 1 0 N C -350 0 12 1 1 0 N C -50 -100 12 1 1 0 N C 150 -100 12 1 1 0 N C -600 300 12 1 1 0 N C -600 0 12 1 1 0 N X +IN 3 -900 -200 200 R 40 40 1 1 I X -IN 2 -900 500 200 R 40 40 1 1 I X J 1 -900 300 200 R 40 40 1 1 P X J@1 8 -900 0 200 R 40 40 1 1 P X OUT 6 700 200 200 L 40 40 1 1 O X REF 5 -900 -400 200 R 40 40 1 1 P X V+ 7 700 -200 200 L 40 40 1 1 W X V- 4 700 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA168 # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA168 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA138 F0 "IC" -300 425 50 H V L B F1 "INA168" -300 -500 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -50 -200 -50 -100 P 2 1 0 0 -50 -100 -50 100 P 2 1 0 0 -50 100 -50 200 P 2 1 0 0 -50 200 150 0 P 2 1 0 0 150 0 -50 -200 P 2 1 0 0 -150 75 -150 100 P 2 1 0 0 -150 100 -150 125 P 2 1 0 0 -150 125 -250 125 P 2 1 0 0 -250 125 -250 100 P 2 1 0 0 -250 100 -250 75 P 2 1 0 0 -250 75 -150 75 P 2 1 0 0 -150 -75 -150 -100 P 2 1 0 0 -150 -100 -150 -125 P 2 1 0 0 -150 -125 -250 -125 P 2 1 0 0 -250 -125 -250 -100 P 2 1 0 0 -250 -100 -250 -75 P 2 1 0 0 -250 -75 -150 -75 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -100 100 -150 100 P 2 1 0 0 -50 -100 -150 -100 P 2 1 0 0 -17 100 7 100 P 2 1 0 0 -17 -100 7 -100 P 2 1 0 0 -5 -87 -5 -112 P 2 1 0 0 -300 100 -250 100 P 2 1 0 0 -300 -100 -250 -100 P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 -100 P 2 1 0 0 300 -100 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -400 P 2 1 0 0 250 50 250 250 P 2 1 0 0 250 250 -100 250 P 2 1 0 0 -100 250 -100 100 P 2 1 0 0 250 -50 240 -40 P 2 1 0 0 240 -40 200 0 P 2 1 0 0 200 0 250 50 P 2 1 0 0 150 0 200 0 P 2 1 0 0 250 -50 230 -10 P 2 1 0 0 230 -10 210 -30 P 2 1 0 0 210 -30 250 -50 P 2 1 0 0 230 -20 220 -30 P 2 1 0 0 220 -30 240 -40 P 2 1 0 0 240 -40 230 -20 P 2 1 0 0 250 -50 250 -100 P 2 1 0 0 250 -100 300 -100 S 190 -40 200 40 1 1 0 F C -100 100 12 1 1 0 N X IN+ 3 -400 -100 100 R 40 40 1 1 I X IN- 4 -400 100 100 R 40 40 1 1 I X OUT 1 400 -100 100 L 40 40 1 1 O X V+ 5 400 300 100 L 40 40 1 1 W X V- 2 400 -300 100 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2126E # Package Name: SSOP16BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2126E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2126 F0 "IC" -300 1125 50 H V L B F1 "INA2126E" -300 -1400 50 H V L B F2 "burr-brown-SSOP16BU" 0 150 50 H I C C DRAW P 2 1 0 0 -100 800 -100 850 P 2 1 0 0 -100 850 -100 950 P 2 1 0 0 -100 950 -100 1000 P 2 1 0 0 -100 1000 100 900 P 2 1 0 0 100 900 -100 800 P 2 1 0 0 -100 950 -150 950 P 2 1 0 0 50 625 50 600 P 2 1 0 0 50 600 50 575 P 2 1 0 0 50 575 -50 575 P 2 1 0 0 -50 575 -50 600 P 2 1 0 0 -50 600 -50 625 P 2 1 0 0 -50 625 50 625 P 2 1 0 0 -50 725 -50 700 P 2 1 0 0 -50 700 -50 675 P 2 1 0 0 -50 675 50 675 P 2 1 0 0 50 675 50 700 P 2 1 0 0 50 700 50 725 P 2 1 0 0 50 725 -50 725 P 2 1 0 0 -100 850 -200 850 P 2 1 0 0 -200 850 -200 800 P 2 1 0 0 -87 950 -62 950 P 2 1 0 0 -87 850 -62 850 P 2 1 0 0 -75 962 -75 937 P 2 1 0 0 100 900 300 900 P 2 1 0 0 -100 200 -100 250 P 2 1 0 0 -100 250 -100 350 P 2 1 0 0 -100 350 -100 400 P 2 1 0 0 -100 400 100 300 P 2 1 0 0 100 300 -100 200 P 2 1 0 0 50 475 50 500 P 2 1 0 0 50 500 50 525 P 2 1 0 0 50 525 -50 525 P 2 1 0 0 -50 525 -50 500 P 2 1 0 0 -50 500 -50 475 P 2 1 0 0 -50 475 50 475 P 2 1 0 0 -50 75 -50 100 P 2 1 0 0 -50 100 -50 125 P 2 1 0 0 -50 125 50 125 P 2 1 0 0 50 125 50 100 P 2 1 0 0 50 100 50 75 P 2 1 0 0 50 75 -50 75 P 2 1 0 0 -100 350 -200 350 P 2 1 0 0 -200 350 -200 400 P 2 1 0 0 -100 250 -150 250 P 2 1 0 0 -87 350 -62 350 P 2 1 0 0 -87 250 -62 250 P 2 1 0 0 -75 262 -75 237 P 2 1 0 0 100 300 175 300 P 2 1 0 0 -300 1000 -150 1000 P 2 1 0 0 -150 1000 -150 950 P 2 1 0 0 -300 800 -200 800 P 2 1 0 0 -200 800 -200 700 P 2 1 0 0 -200 700 -50 700 P 2 1 0 0 -150 250 -150 200 P 2 1 0 0 -150 200 -300 200 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 -200 600 -50 600 P 2 1 0 0 -200 700 -200 600 P 2 1 0 0 50 600 175 600 P 2 1 0 0 175 600 175 300 P 2 1 0 0 50 500 162 500 P 2 1 0 0 -50 500 -200 500 P 2 1 0 0 -200 500 -200 400 P 2 1 0 0 -200 350 -200 100 P 2 1 0 0 50 100 287 100 P 2 1 0 0 -200 100 -50 100 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 -100 -50 -150 -50 P 2 1 0 0 50 -375 50 -400 P 2 1 0 0 50 -400 50 -425 P 2 1 0 0 50 -425 -50 -425 P 2 1 0 0 -50 -425 -50 -400 P 2 1 0 0 -50 -400 -50 -375 P 2 1 0 0 -50 -375 50 -375 P 2 1 0 0 -50 -275 -50 -300 P 2 1 0 0 -50 -300 -50 -325 P 2 1 0 0 -50 -325 50 -325 P 2 1 0 0 50 -325 50 -300 P 2 1 0 0 50 -300 50 -275 P 2 1 0 0 50 -275 -50 -275 P 2 1 0 0 -100 -150 -200 -150 P 2 1 0 0 -200 -150 -200 -200 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -37 -75 -62 P 2 1 0 0 100 -100 300 -100 P 2 1 0 0 -100 -800 -100 -750 P 2 1 0 0 -100 -750 -100 -650 P 2 1 0 0 -100 -650 -100 -600 P 2 1 0 0 -100 -600 100 -700 P 2 1 0 0 100 -700 -100 -800 P 2 1 0 0 50 -525 50 -500 P 2 1 0 0 50 -500 50 -475 P 2 1 0 0 50 -475 -50 -475 P 2 1 0 0 -50 -475 -50 -500 P 2 1 0 0 -50 -500 -50 -525 P 2 1 0 0 -50 -525 50 -525 P 2 1 0 0 -50 -925 -50 -900 P 2 1 0 0 -50 -900 -50 -875 P 2 1 0 0 -50 -875 50 -875 P 2 1 0 0 50 -875 50 -900 P 2 1 0 0 50 -900 50 -925 P 2 1 0 0 50 -925 -50 -925 P 2 1 0 0 -100 -650 -200 -650 P 2 1 0 0 -200 -650 -200 -600 P 2 1 0 0 -100 -750 -150 -750 P 2 1 0 0 -87 -650 -62 -650 P 2 1 0 0 -87 -750 -62 -750 P 2 1 0 0 -75 -737 -75 -762 P 2 1 0 0 100 -700 175 -700 P 2 1 0 0 -300 0 -150 0 P 2 1 0 0 -150 0 -150 -50 P 2 1 0 0 -300 -200 -200 -200 P 2 1 0 0 -200 -200 -200 -300 P 2 1 0 0 -200 -300 -50 -300 P 2 1 0 0 -150 -750 -150 -800 P 2 1 0 0 -150 -800 -300 -800 P 2 1 0 0 -300 -600 -200 -600 P 2 1 0 0 -200 -400 -50 -400 P 2 1 0 0 -200 -300 -200 -400 P 2 1 0 0 50 -400 175 -400 P 2 1 0 0 175 -400 175 -700 P 2 1 0 0 50 -500 162 -500 P 2 1 0 0 -50 -500 -200 -500 P 2 1 0 0 -200 -500 -200 -600 P 2 1 0 0 -200 -650 -200 -900 P 2 1 0 0 -200 -900 -50 -900 P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1100 P 2 1 0 0 -300 1100 300 1100 P 2 1 0 0 300 1100 300 -300 P 2 1 0 0 300 -300 300 -900 P 2 1 0 0 300 -900 300 -1300 P 2 1 0 0 50 700 300 700 P 2 1 0 0 50 -900 300 -900 P 2 1 0 0 50 -300 300 -300 C -200 800 12 1 1 0 N C -200 700 12 1 1 0 N C -200 400 12 1 1 0 N C -200 350 12 1 1 0 N C 175 500 12 1 1 0 N C -200 -200 12 1 1 0 N C -200 -300 12 1 1 0 N C -200 -600 12 1 1 0 N C -200 -650 12 1 1 0 N C 175 -500 12 1 1 0 N X +INA 2 -500 1000 200 R 40 40 1 1 I X +INB 15 -500 0 200 R 40 40 1 1 I X -INA 1 -500 200 200 R 40 40 1 1 I X -INB 16 -500 -800 200 R 40 40 1 1 I X OUTA 6 500 900 200 L 40 40 1 1 O X OUTB 11 500 -100 200 L 40 40 1 1 O X REFA 5 500 100 200 L 40 40 1 1 W X REFB 12 500 -900 200 L 40 40 1 1 W X RGA 3 -500 800 200 R 40 40 1 1 P X RGA@1 4 -500 400 200 R 40 40 1 1 P X RGB 13 -500 -200 200 R 40 40 1 1 P X RGB@1 14 -500 -600 200 R 40 40 1 1 P X SENSEA 7 500 700 200 L 40 40 1 1 P X SENSEB 10 500 -300 200 L 40 40 1 1 P X V+ 9 500 -1000 200 L 40 40 1 1 W X V- 8 500 -1200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2126P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2126P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2126 F0 "IC" -300 1125 50 H V L B F1 "INA2126P" -300 -1400 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -100 800 -100 850 P 2 1 0 0 -100 850 -100 950 P 2 1 0 0 -100 950 -100 1000 P 2 1 0 0 -100 1000 100 900 P 2 1 0 0 100 900 -100 800 P 2 1 0 0 -100 950 -150 950 P 2 1 0 0 50 625 50 600 P 2 1 0 0 50 600 50 575 P 2 1 0 0 50 575 -50 575 P 2 1 0 0 -50 575 -50 600 P 2 1 0 0 -50 600 -50 625 P 2 1 0 0 -50 625 50 625 P 2 1 0 0 -50 725 -50 700 P 2 1 0 0 -50 700 -50 675 P 2 1 0 0 -50 675 50 675 P 2 1 0 0 50 675 50 700 P 2 1 0 0 50 700 50 725 P 2 1 0 0 50 725 -50 725 P 2 1 0 0 -100 850 -200 850 P 2 1 0 0 -200 850 -200 800 P 2 1 0 0 -87 950 -62 950 P 2 1 0 0 -87 850 -62 850 P 2 1 0 0 -75 962 -75 937 P 2 1 0 0 100 900 300 900 P 2 1 0 0 -100 200 -100 250 P 2 1 0 0 -100 250 -100 350 P 2 1 0 0 -100 350 -100 400 P 2 1 0 0 -100 400 100 300 P 2 1 0 0 100 300 -100 200 P 2 1 0 0 50 475 50 500 P 2 1 0 0 50 500 50 525 P 2 1 0 0 50 525 -50 525 P 2 1 0 0 -50 525 -50 500 P 2 1 0 0 -50 500 -50 475 P 2 1 0 0 -50 475 50 475 P 2 1 0 0 -50 75 -50 100 P 2 1 0 0 -50 100 -50 125 P 2 1 0 0 -50 125 50 125 P 2 1 0 0 50 125 50 100 P 2 1 0 0 50 100 50 75 P 2 1 0 0 50 75 -50 75 P 2 1 0 0 -100 350 -200 350 P 2 1 0 0 -200 350 -200 400 P 2 1 0 0 -100 250 -150 250 P 2 1 0 0 -87 350 -62 350 P 2 1 0 0 -87 250 -62 250 P 2 1 0 0 -75 262 -75 237 P 2 1 0 0 100 300 175 300 P 2 1 0 0 -300 1000 -150 1000 P 2 1 0 0 -150 1000 -150 950 P 2 1 0 0 -300 800 -200 800 P 2 1 0 0 -200 800 -200 700 P 2 1 0 0 -200 700 -50 700 P 2 1 0 0 -150 250 -150 200 P 2 1 0 0 -150 200 -300 200 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 -200 600 -50 600 P 2 1 0 0 -200 700 -200 600 P 2 1 0 0 50 600 175 600 P 2 1 0 0 175 600 175 300 P 2 1 0 0 50 500 162 500 P 2 1 0 0 -50 500 -200 500 P 2 1 0 0 -200 500 -200 400 P 2 1 0 0 -200 350 -200 100 P 2 1 0 0 50 100 287 100 P 2 1 0 0 -200 100 -50 100 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 -100 -50 -150 -50 P 2 1 0 0 50 -375 50 -400 P 2 1 0 0 50 -400 50 -425 P 2 1 0 0 50 -425 -50 -425 P 2 1 0 0 -50 -425 -50 -400 P 2 1 0 0 -50 -400 -50 -375 P 2 1 0 0 -50 -375 50 -375 P 2 1 0 0 -50 -275 -50 -300 P 2 1 0 0 -50 -300 -50 -325 P 2 1 0 0 -50 -325 50 -325 P 2 1 0 0 50 -325 50 -300 P 2 1 0 0 50 -300 50 -275 P 2 1 0 0 50 -275 -50 -275 P 2 1 0 0 -100 -150 -200 -150 P 2 1 0 0 -200 -150 -200 -200 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -37 -75 -62 P 2 1 0 0 100 -100 300 -100 P 2 1 0 0 -100 -800 -100 -750 P 2 1 0 0 -100 -750 -100 -650 P 2 1 0 0 -100 -650 -100 -600 P 2 1 0 0 -100 -600 100 -700 P 2 1 0 0 100 -700 -100 -800 P 2 1 0 0 50 -525 50 -500 P 2 1 0 0 50 -500 50 -475 P 2 1 0 0 50 -475 -50 -475 P 2 1 0 0 -50 -475 -50 -500 P 2 1 0 0 -50 -500 -50 -525 P 2 1 0 0 -50 -525 50 -525 P 2 1 0 0 -50 -925 -50 -900 P 2 1 0 0 -50 -900 -50 -875 P 2 1 0 0 -50 -875 50 -875 P 2 1 0 0 50 -875 50 -900 P 2 1 0 0 50 -900 50 -925 P 2 1 0 0 50 -925 -50 -925 P 2 1 0 0 -100 -650 -200 -650 P 2 1 0 0 -200 -650 -200 -600 P 2 1 0 0 -100 -750 -150 -750 P 2 1 0 0 -87 -650 -62 -650 P 2 1 0 0 -87 -750 -62 -750 P 2 1 0 0 -75 -737 -75 -762 P 2 1 0 0 100 -700 175 -700 P 2 1 0 0 -300 0 -150 0 P 2 1 0 0 -150 0 -150 -50 P 2 1 0 0 -300 -200 -200 -200 P 2 1 0 0 -200 -200 -200 -300 P 2 1 0 0 -200 -300 -50 -300 P 2 1 0 0 -150 -750 -150 -800 P 2 1 0 0 -150 -800 -300 -800 P 2 1 0 0 -300 -600 -200 -600 P 2 1 0 0 -200 -400 -50 -400 P 2 1 0 0 -200 -300 -200 -400 P 2 1 0 0 50 -400 175 -400 P 2 1 0 0 175 -400 175 -700 P 2 1 0 0 50 -500 162 -500 P 2 1 0 0 -50 -500 -200 -500 P 2 1 0 0 -200 -500 -200 -600 P 2 1 0 0 -200 -650 -200 -900 P 2 1 0 0 -200 -900 -50 -900 P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1100 P 2 1 0 0 -300 1100 300 1100 P 2 1 0 0 300 1100 300 -300 P 2 1 0 0 300 -300 300 -900 P 2 1 0 0 300 -900 300 -1300 P 2 1 0 0 50 700 300 700 P 2 1 0 0 50 -900 300 -900 P 2 1 0 0 50 -300 300 -300 C -200 800 12 1 1 0 N C -200 700 12 1 1 0 N C -200 400 12 1 1 0 N C -200 350 12 1 1 0 N C 175 500 12 1 1 0 N C -200 -200 12 1 1 0 N C -200 -300 12 1 1 0 N C -200 -600 12 1 1 0 N C -200 -650 12 1 1 0 N C 175 -500 12 1 1 0 N X +INA 2 -500 1000 200 R 40 40 1 1 I X +INB 15 -500 0 200 R 40 40 1 1 I X -INA 1 -500 200 200 R 40 40 1 1 I X -INB 16 -500 -800 200 R 40 40 1 1 I X OUTA 6 500 900 200 L 40 40 1 1 O X OUTB 11 500 -100 200 L 40 40 1 1 O X REFA 5 500 100 200 L 40 40 1 1 W X REFB 12 500 -900 200 L 40 40 1 1 W X RGA 3 -500 800 200 R 40 40 1 1 P X RGA@1 4 -500 400 200 R 40 40 1 1 P X RGB 13 -500 -200 200 R 40 40 1 1 P X RGB@1 14 -500 -600 200 R 40 40 1 1 P X SENSEA 7 500 700 200 L 40 40 1 1 P X SENSEB 10 500 -300 200 L 40 40 1 1 P X V+ 9 500 -1000 200 L 40 40 1 1 W X V- 8 500 -1200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2126U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2126U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2126 F0 "IC" -300 1125 50 H V L B F1 "INA2126U" -300 -1400 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -100 800 -100 850 P 2 1 0 0 -100 850 -100 950 P 2 1 0 0 -100 950 -100 1000 P 2 1 0 0 -100 1000 100 900 P 2 1 0 0 100 900 -100 800 P 2 1 0 0 -100 950 -150 950 P 2 1 0 0 50 625 50 600 P 2 1 0 0 50 600 50 575 P 2 1 0 0 50 575 -50 575 P 2 1 0 0 -50 575 -50 600 P 2 1 0 0 -50 600 -50 625 P 2 1 0 0 -50 625 50 625 P 2 1 0 0 -50 725 -50 700 P 2 1 0 0 -50 700 -50 675 P 2 1 0 0 -50 675 50 675 P 2 1 0 0 50 675 50 700 P 2 1 0 0 50 700 50 725 P 2 1 0 0 50 725 -50 725 P 2 1 0 0 -100 850 -200 850 P 2 1 0 0 -200 850 -200 800 P 2 1 0 0 -87 950 -62 950 P 2 1 0 0 -87 850 -62 850 P 2 1 0 0 -75 962 -75 937 P 2 1 0 0 100 900 300 900 P 2 1 0 0 -100 200 -100 250 P 2 1 0 0 -100 250 -100 350 P 2 1 0 0 -100 350 -100 400 P 2 1 0 0 -100 400 100 300 P 2 1 0 0 100 300 -100 200 P 2 1 0 0 50 475 50 500 P 2 1 0 0 50 500 50 525 P 2 1 0 0 50 525 -50 525 P 2 1 0 0 -50 525 -50 500 P 2 1 0 0 -50 500 -50 475 P 2 1 0 0 -50 475 50 475 P 2 1 0 0 -50 75 -50 100 P 2 1 0 0 -50 100 -50 125 P 2 1 0 0 -50 125 50 125 P 2 1 0 0 50 125 50 100 P 2 1 0 0 50 100 50 75 P 2 1 0 0 50 75 -50 75 P 2 1 0 0 -100 350 -200 350 P 2 1 0 0 -200 350 -200 400 P 2 1 0 0 -100 250 -150 250 P 2 1 0 0 -87 350 -62 350 P 2 1 0 0 -87 250 -62 250 P 2 1 0 0 -75 262 -75 237 P 2 1 0 0 100 300 175 300 P 2 1 0 0 -300 1000 -150 1000 P 2 1 0 0 -150 1000 -150 950 P 2 1 0 0 -300 800 -200 800 P 2 1 0 0 -200 800 -200 700 P 2 1 0 0 -200 700 -50 700 P 2 1 0 0 -150 250 -150 200 P 2 1 0 0 -150 200 -300 200 P 2 1 0 0 -300 400 -200 400 P 2 1 0 0 -200 600 -50 600 P 2 1 0 0 -200 700 -200 600 P 2 1 0 0 50 600 175 600 P 2 1 0 0 175 600 175 300 P 2 1 0 0 50 500 162 500 P 2 1 0 0 -50 500 -200 500 P 2 1 0 0 -200 500 -200 400 P 2 1 0 0 -200 350 -200 100 P 2 1 0 0 50 100 287 100 P 2 1 0 0 -200 100 -50 100 P 2 1 0 0 -100 -200 -100 -150 P 2 1 0 0 -100 -150 -100 -50 P 2 1 0 0 -100 -50 -100 0 P 2 1 0 0 -100 0 100 -100 P 2 1 0 0 100 -100 -100 -200 P 2 1 0 0 -100 -50 -150 -50 P 2 1 0 0 50 -375 50 -400 P 2 1 0 0 50 -400 50 -425 P 2 1 0 0 50 -425 -50 -425 P 2 1 0 0 -50 -425 -50 -400 P 2 1 0 0 -50 -400 -50 -375 P 2 1 0 0 -50 -375 50 -375 P 2 1 0 0 -50 -275 -50 -300 P 2 1 0 0 -50 -300 -50 -325 P 2 1 0 0 -50 -325 50 -325 P 2 1 0 0 50 -325 50 -300 P 2 1 0 0 50 -300 50 -275 P 2 1 0 0 50 -275 -50 -275 P 2 1 0 0 -100 -150 -200 -150 P 2 1 0 0 -200 -150 -200 -200 P 2 1 0 0 -87 -50 -62 -50 P 2 1 0 0 -87 -150 -62 -150 P 2 1 0 0 -75 -37 -75 -62 P 2 1 0 0 100 -100 300 -100 P 2 1 0 0 -100 -800 -100 -750 P 2 1 0 0 -100 -750 -100 -650 P 2 1 0 0 -100 -650 -100 -600 P 2 1 0 0 -100 -600 100 -700 P 2 1 0 0 100 -700 -100 -800 P 2 1 0 0 50 -525 50 -500 P 2 1 0 0 50 -500 50 -475 P 2 1 0 0 50 -475 -50 -475 P 2 1 0 0 -50 -475 -50 -500 P 2 1 0 0 -50 -500 -50 -525 P 2 1 0 0 -50 -525 50 -525 P 2 1 0 0 -50 -925 -50 -900 P 2 1 0 0 -50 -900 -50 -875 P 2 1 0 0 -50 -875 50 -875 P 2 1 0 0 50 -875 50 -900 P 2 1 0 0 50 -900 50 -925 P 2 1 0 0 50 -925 -50 -925 P 2 1 0 0 -100 -650 -200 -650 P 2 1 0 0 -200 -650 -200 -600 P 2 1 0 0 -100 -750 -150 -750 P 2 1 0 0 -87 -650 -62 -650 P 2 1 0 0 -87 -750 -62 -750 P 2 1 0 0 -75 -737 -75 -762 P 2 1 0 0 100 -700 175 -700 P 2 1 0 0 -300 0 -150 0 P 2 1 0 0 -150 0 -150 -50 P 2 1 0 0 -300 -200 -200 -200 P 2 1 0 0 -200 -200 -200 -300 P 2 1 0 0 -200 -300 -50 -300 P 2 1 0 0 -150 -750 -150 -800 P 2 1 0 0 -150 -800 -300 -800 P 2 1 0 0 -300 -600 -200 -600 P 2 1 0 0 -200 -400 -50 -400 P 2 1 0 0 -200 -300 -200 -400 P 2 1 0 0 50 -400 175 -400 P 2 1 0 0 175 -400 175 -700 P 2 1 0 0 50 -500 162 -500 P 2 1 0 0 -50 -500 -200 -500 P 2 1 0 0 -200 -500 -200 -600 P 2 1 0 0 -200 -650 -200 -900 P 2 1 0 0 -200 -900 -50 -900 P 2 1 0 0 300 -1300 -300 -1300 P 2 1 0 0 -300 -1300 -300 1100 P 2 1 0 0 -300 1100 300 1100 P 2 1 0 0 300 1100 300 -300 P 2 1 0 0 300 -300 300 -900 P 2 1 0 0 300 -900 300 -1300 P 2 1 0 0 50 700 300 700 P 2 1 0 0 50 -900 300 -900 P 2 1 0 0 50 -300 300 -300 C -200 800 12 1 1 0 N C -200 700 12 1 1 0 N C -200 400 12 1 1 0 N C -200 350 12 1 1 0 N C 175 500 12 1 1 0 N C -200 -200 12 1 1 0 N C -200 -300 12 1 1 0 N C -200 -600 12 1 1 0 N C -200 -650 12 1 1 0 N C 175 -500 12 1 1 0 N X +INA 2 -500 1000 200 R 40 40 1 1 I X +INB 15 -500 0 200 R 40 40 1 1 I X -INA 1 -500 200 200 R 40 40 1 1 I X -INB 16 -500 -800 200 R 40 40 1 1 I X OUTA 6 500 900 200 L 40 40 1 1 O X OUTB 11 500 -100 200 L 40 40 1 1 O X REFA 5 500 100 200 L 40 40 1 1 W X REFB 12 500 -900 200 L 40 40 1 1 W X RGA 3 -500 800 200 R 40 40 1 1 P X RGA@1 4 -500 400 200 R 40 40 1 1 P X RGB 13 -500 -200 200 R 40 40 1 1 P X RGB@1 14 -500 -600 200 R 40 40 1 1 P X SENSEA 7 500 700 200 L 40 40 1 1 P X SENSEB 10 500 -300 200 L 40 40 1 1 P X V+ 9 500 -1000 200 L 40 40 1 1 W X V- 8 500 -1200 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2128P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2128P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2128 F0 "IC" -500 1025 50 H V L B F1 "INA2128P" -500 -1000 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 700 -400 750 P 2 1 0 0 -400 750 -400 850 P 2 1 0 0 -400 850 -400 900 P 2 1 0 0 -400 900 -200 800 P 2 1 0 0 -200 800 -400 700 P 2 1 0 0 -200 575 -200 600 P 2 1 0 0 -200 600 -200 625 P 2 1 0 0 -200 625 -300 625 P 2 1 0 0 -300 625 -300 600 P 2 1 0 0 -300 600 -300 575 P 2 1 0 0 -300 575 -200 575 P 2 1 0 0 -100 775 -100 800 P 2 1 0 0 -100 800 -100 825 P 2 1 0 0 -100 825 0 825 P 2 1 0 0 0 825 0 800 P 2 1 0 0 0 800 0 775 P 2 1 0 0 0 775 -100 775 P 2 1 0 0 -400 850 -450 850 P 2 1 0 0 200 825 200 800 P 2 1 0 0 200 800 200 775 P 2 1 0 0 200 775 100 775 P 2 1 0 0 100 775 100 800 P 2 1 0 0 100 800 100 825 P 2 1 0 0 100 825 200 825 P 2 1 0 0 100 325 100 300 P 2 1 0 0 100 300 100 275 P 2 1 0 0 100 275 200 275 P 2 1 0 0 200 275 200 300 P 2 1 0 0 200 300 200 325 P 2 1 0 0 200 325 100 325 P 2 1 0 0 -400 750 -450 750 P 2 1 0 0 -387 850 -362 850 P 2 1 0 0 -387 750 -362 750 P 2 1 0 0 -375 862 -375 837 P 2 1 0 0 -400 200 -400 250 P 2 1 0 0 -400 250 -400 350 P 2 1 0 0 -400 350 -400 400 P 2 1 0 0 -400 400 -200 300 P 2 1 0 0 -200 300 -400 200 P 2 1 0 0 0 275 0 300 P 2 1 0 0 0 300 0 325 P 2 1 0 0 0 325 -100 325 P 2 1 0 0 -100 325 -100 300 P 2 1 0 0 -100 300 -100 275 P 2 1 0 0 -100 275 0 275 P 2 1 0 0 -300 475 -300 500 P 2 1 0 0 -300 500 -300 525 P 2 1 0 0 -300 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -300 475 P 2 1 0 0 -400 350 -450 350 P 2 1 0 0 -400 250 -450 250 P 2 1 0 0 -387 350 -362 350 P 2 1 0 0 -387 250 -362 250 P 2 1 0 0 -375 262 -375 237 P 2 1 0 0 -450 850 -450 900 P 2 1 0 0 -450 900 -500 900 P 2 1 0 0 -450 750 -450 700 P 2 1 0 0 -450 700 -500 700 P 2 1 0 0 100 500 100 550 P 2 1 0 0 100 550 100 650 P 2 1 0 0 100 650 100 700 P 2 1 0 0 100 700 300 600 P 2 1 0 0 300 600 100 500 P 2 1 0 0 100 550 50 550 P 2 1 0 0 112 650 137 650 P 2 1 0 0 112 550 137 550 P 2 1 0 0 125 562 125 537 P 2 1 0 0 -200 800 -150 800 P 2 1 0 0 -150 800 -100 800 P 2 1 0 0 0 800 50 800 P 2 1 0 0 50 800 100 800 P 2 1 0 0 300 600 400 600 P 2 1 0 0 -450 700 -450 600 P 2 1 0 0 -450 600 -300 600 P 2 1 0 0 -150 800 -150 600 P 2 1 0 0 -150 600 -200 600 P 2 1 0 0 50 800 50 650 P 2 1 0 0 50 650 100 650 P 2 1 0 0 -300 500 -450 500 P 2 1 0 0 -450 500 -450 400 P 2 1 0 0 -450 400 -450 350 P 2 1 0 0 -200 500 -150 500 P 2 1 0 0 -150 500 -150 300 P 2 1 0 0 -150 300 -200 300 P 2 1 0 0 -150 300 -100 300 P 2 1 0 0 0 300 50 300 P 2 1 0 0 50 300 100 300 P 2 1 0 0 -450 250 -450 200 P 2 1 0 0 -450 200 -500 200 P 2 1 0 0 -500 400 -450 400 P 2 1 0 0 50 550 50 300 P 2 1 0 0 200 300 400 300 P 2 1 0 0 400 800 200 800 P 2 1 0 0 -400 -100 -400 -50 P 2 1 0 0 -400 -50 -400 50 P 2 1 0 0 -400 50 -400 100 P 2 1 0 0 -400 100 -200 0 P 2 1 0 0 -200 0 -400 -100 P 2 1 0 0 -200 -225 -200 -200 P 2 1 0 0 -200 -200 -200 -175 P 2 1 0 0 -200 -175 -300 -175 P 2 1 0 0 -300 -175 -300 -200 P 2 1 0 0 -300 -200 -300 -225 P 2 1 0 0 -300 -225 -200 -225 P 2 1 0 0 -100 -25 -100 0 P 2 1 0 0 -100 0 -100 25 P 2 1 0 0 -100 25 0 25 P 2 1 0 0 0 25 0 0 P 2 1 0 0 0 0 0 -25 P 2 1 0 0 0 -25 -100 -25 P 2 1 0 0 -400 50 -450 50 P 2 1 0 0 200 25 200 0 P 2 1 0 0 200 0 200 -25 P 2 1 0 0 200 -25 100 -25 P 2 1 0 0 100 -25 100 0 P 2 1 0 0 100 0 100 25 P 2 1 0 0 100 25 200 25 P 2 1 0 0 100 -475 100 -500 P 2 1 0 0 100 -500 100 -525 P 2 1 0 0 100 -525 200 -525 P 2 1 0 0 200 -525 200 -500 P 2 1 0 0 200 -500 200 -475 P 2 1 0 0 200 -475 100 -475 P 2 1 0 0 -400 -50 -450 -50 P 2 1 0 0 -387 50 -362 50 P 2 1 0 0 -387 -50 -362 -50 P 2 1 0 0 -375 62 -375 37 P 2 1 0 0 -400 -600 -400 -550 P 2 1 0 0 -400 -550 -400 -450 P 2 1 0 0 -400 -450 -400 -400 P 2 1 0 0 -400 -400 -200 -500 P 2 1 0 0 -200 -500 -400 -600 P 2 1 0 0 0 -525 0 -500 P 2 1 0 0 0 -500 0 -475 P 2 1 0 0 0 -475 -100 -475 P 2 1 0 0 -100 -475 -100 -500 P 2 1 0 0 -100 -500 -100 -525 P 2 1 0 0 -100 -525 0 -525 P 2 1 0 0 -300 -325 -300 -300 P 2 1 0 0 -300 -300 -300 -275 P 2 1 0 0 -300 -275 -200 -275 P 2 1 0 0 -200 -275 -200 -300 P 2 1 0 0 -200 -300 -200 -325 P 2 1 0 0 -200 -325 -300 -325 P 2 1 0 0 -400 -450 -450 -450 P 2 1 0 0 -400 -550 -450 -550 P 2 1 0 0 -387 -450 -362 -450 P 2 1 0 0 -387 -550 -362 -550 P 2 1 0 0 -375 -537 -375 -562 P 2 1 0 0 -450 50 -450 100 P 2 1 0 0 -450 100 -500 100 P 2 1 0 0 -450 -50 -450 -100 P 2 1 0 0 -450 -100 -500 -100 P 2 1 0 0 100 -300 100 -250 P 2 1 0 0 100 -250 100 -150 P 2 1 0 0 100 -150 100 -100 P 2 1 0 0 100 -100 300 -200 P 2 1 0 0 300 -200 100 -300 P 2 1 0 0 100 -250 50 -250 P 2 1 0 0 112 -150 137 -150 P 2 1 0 0 112 -250 137 -250 P 2 1 0 0 125 -237 125 -262 P 2 1 0 0 -200 0 -150 0 P 2 1 0 0 -150 0 -100 0 P 2 1 0 0 0 0 50 0 P 2 1 0 0 50 0 100 0 P 2 1 0 0 300 -200 400 -200 P 2 1 0 0 -450 -100 -450 -200 P 2 1 0 0 -450 -200 -300 -200 P 2 1 0 0 -150 0 -150 -200 P 2 1 0 0 -150 -200 -200 -200 P 2 1 0 0 50 0 50 -150 P 2 1 0 0 50 -150 100 -150 P 2 1 0 0 -300 -300 -450 -300 P 2 1 0 0 -450 -300 -450 -400 P 2 1 0 0 -450 -400 -450 -450 P 2 1 0 0 -200 -300 -150 -300 P 2 1 0 0 -150 -300 -150 -500 P 2 1 0 0 -150 -500 -200 -500 P 2 1 0 0 -150 -500 -100 -500 P 2 1 0 0 0 -500 50 -500 P 2 1 0 0 50 -500 100 -500 P 2 1 0 0 -450 -550 -450 -600 P 2 1 0 0 -450 -600 -500 -600 P 2 1 0 0 -500 -400 -450 -400 P 2 1 0 0 50 -250 50 -500 P 2 1 0 0 200 -500 400 -500 P 2 1 0 0 400 0 200 0 P 2 1 0 0 -500 -900 -500 1000 P 2 1 0 0 -500 1000 400 1000 P 2 1 0 0 400 1000 400 -900 P 2 1 0 0 400 -900 -500 -900 C -450 700 12 1 1 0 N C -150 800 12 1 1 0 N C 50 800 12 1 1 0 N C -450 400 12 1 1 0 N C -150 300 12 1 1 0 N C 50 300 12 1 1 0 N C -450 -100 12 1 1 0 N C -150 0 12 1 1 0 N C 50 0 12 1 1 0 N C -450 -400 12 1 1 0 N C -150 -500 12 1 1 0 N C 50 -500 12 1 1 0 N X INA+ 2 -700 200 200 R 40 40 1 1 I X INA- 1 -700 900 200 R 40 40 1 1 I X INB+ 15 -700 -600 200 R 40 40 1 1 I X INB- 16 -700 100 200 R 40 40 1 1 I X REFA 5 600 300 200 L 40 40 1 1 I X REFB 12 600 -500 200 L 40 40 1 1 I X RGA 3 -700 700 200 R 40 40 1 1 P X RGA@1 4 -700 400 200 R 40 40 1 1 P X RGB 13 -700 -100 200 R 40 40 1 1 P X RGB@1 14 -700 -400 200 R 40 40 1 1 P X SENSEA 7 600 800 200 L 40 40 1 1 I X SENSEB 10 600 0 200 L 40 40 1 1 I X V+ 9 600 -600 200 L 40 40 1 1 W X V- 8 600 -800 200 L 40 40 1 1 W X VOA 6 600 600 200 L 40 40 1 1 O X VOB 11 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: INA2128U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2128U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2128 F0 "IC" -500 1025 50 H V L B F1 "INA2128U" -500 -1000 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -400 700 -400 750 P 2 1 0 0 -400 750 -400 850 P 2 1 0 0 -400 850 -400 900 P 2 1 0 0 -400 900 -200 800 P 2 1 0 0 -200 800 -400 700 P 2 1 0 0 -200 575 -200 600 P 2 1 0 0 -200 600 -200 625 P 2 1 0 0 -200 625 -300 625 P 2 1 0 0 -300 625 -300 600 P 2 1 0 0 -300 600 -300 575 P 2 1 0 0 -300 575 -200 575 P 2 1 0 0 -100 775 -100 800 P 2 1 0 0 -100 800 -100 825 P 2 1 0 0 -100 825 0 825 P 2 1 0 0 0 825 0 800 P 2 1 0 0 0 800 0 775 P 2 1 0 0 0 775 -100 775 P 2 1 0 0 -400 850 -450 850 P 2 1 0 0 200 825 200 800 P 2 1 0 0 200 800 200 775 P 2 1 0 0 200 775 100 775 P 2 1 0 0 100 775 100 800 P 2 1 0 0 100 800 100 825 P 2 1 0 0 100 825 200 825 P 2 1 0 0 100 325 100 300 P 2 1 0 0 100 300 100 275 P 2 1 0 0 100 275 200 275 P 2 1 0 0 200 275 200 300 P 2 1 0 0 200 300 200 325 P 2 1 0 0 200 325 100 325 P 2 1 0 0 -400 750 -450 750 P 2 1 0 0 -387 850 -362 850 P 2 1 0 0 -387 750 -362 750 P 2 1 0 0 -375 862 -375 837 P 2 1 0 0 -400 200 -400 250 P 2 1 0 0 -400 250 -400 350 P 2 1 0 0 -400 350 -400 400 P 2 1 0 0 -400 400 -200 300 P 2 1 0 0 -200 300 -400 200 P 2 1 0 0 0 275 0 300 P 2 1 0 0 0 300 0 325 P 2 1 0 0 0 325 -100 325 P 2 1 0 0 -100 325 -100 300 P 2 1 0 0 -100 300 -100 275 P 2 1 0 0 -100 275 0 275 P 2 1 0 0 -300 475 -300 500 P 2 1 0 0 -300 500 -300 525 P 2 1 0 0 -300 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -300 475 P 2 1 0 0 -400 350 -450 350 P 2 1 0 0 -400 250 -450 250 P 2 1 0 0 -387 350 -362 350 P 2 1 0 0 -387 250 -362 250 P 2 1 0 0 -375 262 -375 237 P 2 1 0 0 -450 850 -450 900 P 2 1 0 0 -450 900 -500 900 P 2 1 0 0 -450 750 -450 700 P 2 1 0 0 -450 700 -500 700 P 2 1 0 0 100 500 100 550 P 2 1 0 0 100 550 100 650 P 2 1 0 0 100 650 100 700 P 2 1 0 0 100 700 300 600 P 2 1 0 0 300 600 100 500 P 2 1 0 0 100 550 50 550 P 2 1 0 0 112 650 137 650 P 2 1 0 0 112 550 137 550 P 2 1 0 0 125 562 125 537 P 2 1 0 0 -200 800 -150 800 P 2 1 0 0 -150 800 -100 800 P 2 1 0 0 0 800 50 800 P 2 1 0 0 50 800 100 800 P 2 1 0 0 300 600 400 600 P 2 1 0 0 -450 700 -450 600 P 2 1 0 0 -450 600 -300 600 P 2 1 0 0 -150 800 -150 600 P 2 1 0 0 -150 600 -200 600 P 2 1 0 0 50 800 50 650 P 2 1 0 0 50 650 100 650 P 2 1 0 0 -300 500 -450 500 P 2 1 0 0 -450 500 -450 400 P 2 1 0 0 -450 400 -450 350 P 2 1 0 0 -200 500 -150 500 P 2 1 0 0 -150 500 -150 300 P 2 1 0 0 -150 300 -200 300 P 2 1 0 0 -150 300 -100 300 P 2 1 0 0 0 300 50 300 P 2 1 0 0 50 300 100 300 P 2 1 0 0 -450 250 -450 200 P 2 1 0 0 -450 200 -500 200 P 2 1 0 0 -500 400 -450 400 P 2 1 0 0 50 550 50 300 P 2 1 0 0 200 300 400 300 P 2 1 0 0 400 800 200 800 P 2 1 0 0 -400 -100 -400 -50 P 2 1 0 0 -400 -50 -400 50 P 2 1 0 0 -400 50 -400 100 P 2 1 0 0 -400 100 -200 0 P 2 1 0 0 -200 0 -400 -100 P 2 1 0 0 -200 -225 -200 -200 P 2 1 0 0 -200 -200 -200 -175 P 2 1 0 0 -200 -175 -300 -175 P 2 1 0 0 -300 -175 -300 -200 P 2 1 0 0 -300 -200 -300 -225 P 2 1 0 0 -300 -225 -200 -225 P 2 1 0 0 -100 -25 -100 0 P 2 1 0 0 -100 0 -100 25 P 2 1 0 0 -100 25 0 25 P 2 1 0 0 0 25 0 0 P 2 1 0 0 0 0 0 -25 P 2 1 0 0 0 -25 -100 -25 P 2 1 0 0 -400 50 -450 50 P 2 1 0 0 200 25 200 0 P 2 1 0 0 200 0 200 -25 P 2 1 0 0 200 -25 100 -25 P 2 1 0 0 100 -25 100 0 P 2 1 0 0 100 0 100 25 P 2 1 0 0 100 25 200 25 P 2 1 0 0 100 -475 100 -500 P 2 1 0 0 100 -500 100 -525 P 2 1 0 0 100 -525 200 -525 P 2 1 0 0 200 -525 200 -500 P 2 1 0 0 200 -500 200 -475 P 2 1 0 0 200 -475 100 -475 P 2 1 0 0 -400 -50 -450 -50 P 2 1 0 0 -387 50 -362 50 P 2 1 0 0 -387 -50 -362 -50 P 2 1 0 0 -375 62 -375 37 P 2 1 0 0 -400 -600 -400 -550 P 2 1 0 0 -400 -550 -400 -450 P 2 1 0 0 -400 -450 -400 -400 P 2 1 0 0 -400 -400 -200 -500 P 2 1 0 0 -200 -500 -400 -600 P 2 1 0 0 0 -525 0 -500 P 2 1 0 0 0 -500 0 -475 P 2 1 0 0 0 -475 -100 -475 P 2 1 0 0 -100 -475 -100 -500 P 2 1 0 0 -100 -500 -100 -525 P 2 1 0 0 -100 -525 0 -525 P 2 1 0 0 -300 -325 -300 -300 P 2 1 0 0 -300 -300 -300 -275 P 2 1 0 0 -300 -275 -200 -275 P 2 1 0 0 -200 -275 -200 -300 P 2 1 0 0 -200 -300 -200 -325 P 2 1 0 0 -200 -325 -300 -325 P 2 1 0 0 -400 -450 -450 -450 P 2 1 0 0 -400 -550 -450 -550 P 2 1 0 0 -387 -450 -362 -450 P 2 1 0 0 -387 -550 -362 -550 P 2 1 0 0 -375 -537 -375 -562 P 2 1 0 0 -450 50 -450 100 P 2 1 0 0 -450 100 -500 100 P 2 1 0 0 -450 -50 -450 -100 P 2 1 0 0 -450 -100 -500 -100 P 2 1 0 0 100 -300 100 -250 P 2 1 0 0 100 -250 100 -150 P 2 1 0 0 100 -150 100 -100 P 2 1 0 0 100 -100 300 -200 P 2 1 0 0 300 -200 100 -300 P 2 1 0 0 100 -250 50 -250 P 2 1 0 0 112 -150 137 -150 P 2 1 0 0 112 -250 137 -250 P 2 1 0 0 125 -237 125 -262 P 2 1 0 0 -200 0 -150 0 P 2 1 0 0 -150 0 -100 0 P 2 1 0 0 0 0 50 0 P 2 1 0 0 50 0 100 0 P 2 1 0 0 300 -200 400 -200 P 2 1 0 0 -450 -100 -450 -200 P 2 1 0 0 -450 -200 -300 -200 P 2 1 0 0 -150 0 -150 -200 P 2 1 0 0 -150 -200 -200 -200 P 2 1 0 0 50 0 50 -150 P 2 1 0 0 50 -150 100 -150 P 2 1 0 0 -300 -300 -450 -300 P 2 1 0 0 -450 -300 -450 -400 P 2 1 0 0 -450 -400 -450 -450 P 2 1 0 0 -200 -300 -150 -300 P 2 1 0 0 -150 -300 -150 -500 P 2 1 0 0 -150 -500 -200 -500 P 2 1 0 0 -150 -500 -100 -500 P 2 1 0 0 0 -500 50 -500 P 2 1 0 0 50 -500 100 -500 P 2 1 0 0 -450 -550 -450 -600 P 2 1 0 0 -450 -600 -500 -600 P 2 1 0 0 -500 -400 -450 -400 P 2 1 0 0 50 -250 50 -500 P 2 1 0 0 200 -500 400 -500 P 2 1 0 0 400 0 200 0 P 2 1 0 0 -500 -900 -500 1000 P 2 1 0 0 -500 1000 400 1000 P 2 1 0 0 400 1000 400 -900 P 2 1 0 0 400 -900 -500 -900 C -450 700 12 1 1 0 N C -150 800 12 1 1 0 N C 50 800 12 1 1 0 N C -450 400 12 1 1 0 N C -150 300 12 1 1 0 N C 50 300 12 1 1 0 N C -450 -100 12 1 1 0 N C -150 0 12 1 1 0 N C 50 0 12 1 1 0 N C -450 -400 12 1 1 0 N C -150 -500 12 1 1 0 N C 50 -500 12 1 1 0 N X INA+ 2 -700 200 200 R 40 40 1 1 I X INA- 1 -700 900 200 R 40 40 1 1 I X INB+ 15 -700 -600 200 R 40 40 1 1 I X INB- 16 -700 100 200 R 40 40 1 1 I X REFA 5 600 300 200 L 40 40 1 1 I X REFB 12 600 -500 200 L 40 40 1 1 I X RGA 3 -700 700 200 R 40 40 1 1 P X RGA@1 4 -700 400 200 R 40 40 1 1 P X RGB 13 -700 -100 200 R 40 40 1 1 P X RGB@1 14 -700 -400 200 R 40 40 1 1 P X SENSEA 7 600 800 200 L 40 40 1 1 I X SENSEB 10 600 0 200 L 40 40 1 1 I X V+ 9 600 -600 200 L 40 40 1 1 W X V- 8 600 -800 200 L 40 40 1 1 W X VOA 6 600 600 200 L 40 40 1 1 O X VOB 11 600 -200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: INA2134P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2134P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2134 F0 "IC" -500 625 50 H V L B F1 "INA2134P" -500 -1000 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 0 200 0 250 P 2 1 0 0 0 250 0 350 P 2 1 0 0 0 350 0 400 P 2 1 0 0 0 400 200 300 P 2 1 0 0 200 300 0 200 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 100 475 100 500 P 2 1 0 0 100 500 100 525 P 2 1 0 0 100 525 200 525 P 2 1 0 0 200 525 200 500 P 2 1 0 0 200 500 200 475 P 2 1 0 0 200 475 100 475 P 2 1 0 0 0 350 -50 350 P 2 1 0 0 -100 125 -100 100 P 2 1 0 0 -100 100 -100 75 P 2 1 0 0 -100 75 -200 75 P 2 1 0 0 -200 75 -200 100 P 2 1 0 0 -200 100 -200 125 P 2 1 0 0 -200 125 -100 125 P 2 1 0 0 100 125 100 100 P 2 1 0 0 100 100 100 75 P 2 1 0 0 100 75 200 75 P 2 1 0 0 200 75 200 100 P 2 1 0 0 200 100 200 125 P 2 1 0 0 200 125 100 125 P 2 1 0 0 -50 350 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 -50 500 100 500 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -50 250 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -50 100 100 100 P 2 1 0 0 12 350 37 350 P 2 1 0 0 12 250 37 250 P 2 1 0 0 25 262 25 237 P 2 1 0 0 -300 500 -200 500 P 2 1 0 0 300 500 200 500 P 2 1 0 0 200 300 300 300 P 2 1 0 0 300 100 200 100 P 2 1 0 0 -300 100 -200 100 P 2 1 0 0 -300 -900 300 -900 P 2 1 0 0 300 -900 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -900 P 2 1 0 0 0 -400 0 -350 P 2 1 0 0 0 -350 0 -250 P 2 1 0 0 0 -250 0 -200 P 2 1 0 0 0 -200 200 -300 P 2 1 0 0 200 -300 0 -400 P 2 1 0 0 -100 -125 -100 -100 P 2 1 0 0 -100 -100 -100 -75 P 2 1 0 0 -100 -75 -200 -75 P 2 1 0 0 -200 -75 -200 -100 P 2 1 0 0 -200 -100 -200 -125 P 2 1 0 0 -200 -125 -100 -125 P 2 1 0 0 100 -125 100 -100 P 2 1 0 0 100 -100 100 -75 P 2 1 0 0 100 -75 200 -75 P 2 1 0 0 200 -75 200 -100 P 2 1 0 0 200 -100 200 -125 P 2 1 0 0 200 -125 100 -125 P 2 1 0 0 0 -250 -50 -250 P 2 1 0 0 -100 -475 -100 -500 P 2 1 0 0 -100 -500 -100 -525 P 2 1 0 0 -100 -525 -200 -525 P 2 1 0 0 -200 -525 -200 -500 P 2 1 0 0 -200 -500 -200 -475 P 2 1 0 0 -200 -475 -100 -475 P 2 1 0 0 100 -475 100 -500 P 2 1 0 0 100 -500 100 -525 P 2 1 0 0 100 -525 200 -525 P 2 1 0 0 200 -525 200 -500 P 2 1 0 0 200 -500 200 -475 P 2 1 0 0 200 -475 100 -475 P 2 1 0 0 -50 -250 -50 -100 P 2 1 0 0 -50 -100 -100 -100 P 2 1 0 0 -50 -100 100 -100 P 2 1 0 0 0 -350 -50 -350 P 2 1 0 0 -50 -350 -50 -500 P 2 1 0 0 -50 -500 -100 -500 P 2 1 0 0 -50 -500 100 -500 P 2 1 0 0 12 -250 37 -250 P 2 1 0 0 12 -350 37 -350 P 2 1 0 0 25 -337 25 -362 P 2 1 0 0 -300 -100 -200 -100 P 2 1 0 0 300 -100 200 -100 P 2 1 0 0 200 -300 300 -300 P 2 1 0 0 300 -500 200 -500 P 2 1 0 0 -300 -500 -200 -500 C -50 500 12 1 1 0 N C -50 100 12 1 1 0 N C -50 -100 12 1 1 0 N C -50 -500 12 1 1 0 N X +INA 3 -500 100 200 R 40 40 1 1 I X +INB 5 -500 -500 200 R 40 40 1 1 I X -INA 2 -500 500 200 R 40 40 1 1 I X -INB 6 -500 -100 200 R 40 40 1 1 I X NC 1 -500 -700 200 R 40 40 1 1 U X NC@1 7 -500 -800 200 R 40 40 1 1 U X OUTA 13 500 300 200 L 40 40 1 1 O X OUTB 9 500 -300 200 L 40 40 1 1 O X REFA 14 500 100 200 L 40 40 1 1 P X REFB 8 500 -500 200 L 40 40 1 1 P X SENSEA 12 500 500 200 L 40 40 1 1 P X SENSEB 10 500 -100 200 L 40 40 1 1 P X V+ 11 500 -600 200 L 40 40 1 1 W X V- 4 500 -800 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2134U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2134U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2134 F0 "IC" -500 625 50 H V L B F1 "INA2134U" -500 -1000 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 0 200 0 250 P 2 1 0 0 0 250 0 350 P 2 1 0 0 0 350 0 400 P 2 1 0 0 0 400 200 300 P 2 1 0 0 200 300 0 200 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 100 475 100 500 P 2 1 0 0 100 500 100 525 P 2 1 0 0 100 525 200 525 P 2 1 0 0 200 525 200 500 P 2 1 0 0 200 500 200 475 P 2 1 0 0 200 475 100 475 P 2 1 0 0 0 350 -50 350 P 2 1 0 0 -100 125 -100 100 P 2 1 0 0 -100 100 -100 75 P 2 1 0 0 -100 75 -200 75 P 2 1 0 0 -200 75 -200 100 P 2 1 0 0 -200 100 -200 125 P 2 1 0 0 -200 125 -100 125 P 2 1 0 0 100 125 100 100 P 2 1 0 0 100 100 100 75 P 2 1 0 0 100 75 200 75 P 2 1 0 0 200 75 200 100 P 2 1 0 0 200 100 200 125 P 2 1 0 0 200 125 100 125 P 2 1 0 0 -50 350 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 -50 500 100 500 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -50 250 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -50 100 100 100 P 2 1 0 0 12 350 37 350 P 2 1 0 0 12 250 37 250 P 2 1 0 0 25 262 25 237 P 2 1 0 0 -300 500 -200 500 P 2 1 0 0 300 500 200 500 P 2 1 0 0 200 300 300 300 P 2 1 0 0 300 100 200 100 P 2 1 0 0 -300 100 -200 100 P 2 1 0 0 -300 -900 300 -900 P 2 1 0 0 300 -900 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -900 P 2 1 0 0 0 -400 0 -350 P 2 1 0 0 0 -350 0 -250 P 2 1 0 0 0 -250 0 -200 P 2 1 0 0 0 -200 200 -300 P 2 1 0 0 200 -300 0 -400 P 2 1 0 0 -100 -125 -100 -100 P 2 1 0 0 -100 -100 -100 -75 P 2 1 0 0 -100 -75 -200 -75 P 2 1 0 0 -200 -75 -200 -100 P 2 1 0 0 -200 -100 -200 -125 P 2 1 0 0 -200 -125 -100 -125 P 2 1 0 0 100 -125 100 -100 P 2 1 0 0 100 -100 100 -75 P 2 1 0 0 100 -75 200 -75 P 2 1 0 0 200 -75 200 -100 P 2 1 0 0 200 -100 200 -125 P 2 1 0 0 200 -125 100 -125 P 2 1 0 0 0 -250 -50 -250 P 2 1 0 0 -100 -475 -100 -500 P 2 1 0 0 -100 -500 -100 -525 P 2 1 0 0 -100 -525 -200 -525 P 2 1 0 0 -200 -525 -200 -500 P 2 1 0 0 -200 -500 -200 -475 P 2 1 0 0 -200 -475 -100 -475 P 2 1 0 0 100 -475 100 -500 P 2 1 0 0 100 -500 100 -525 P 2 1 0 0 100 -525 200 -525 P 2 1 0 0 200 -525 200 -500 P 2 1 0 0 200 -500 200 -475 P 2 1 0 0 200 -475 100 -475 P 2 1 0 0 -50 -250 -50 -100 P 2 1 0 0 -50 -100 -100 -100 P 2 1 0 0 -50 -100 100 -100 P 2 1 0 0 0 -350 -50 -350 P 2 1 0 0 -50 -350 -50 -500 P 2 1 0 0 -50 -500 -100 -500 P 2 1 0 0 -50 -500 100 -500 P 2 1 0 0 12 -250 37 -250 P 2 1 0 0 12 -350 37 -350 P 2 1 0 0 25 -337 25 -362 P 2 1 0 0 -300 -100 -200 -100 P 2 1 0 0 300 -100 200 -100 P 2 1 0 0 200 -300 300 -300 P 2 1 0 0 300 -500 200 -500 P 2 1 0 0 -300 -500 -200 -500 C -50 500 12 1 1 0 N C -50 100 12 1 1 0 N C -50 -100 12 1 1 0 N C -50 -500 12 1 1 0 N X +INA 3 -500 100 200 R 40 40 1 1 I X +INB 5 -500 -500 200 R 40 40 1 1 I X -INA 2 -500 500 200 R 40 40 1 1 I X -INB 6 -500 -100 200 R 40 40 1 1 I X NC 1 -500 -700 200 R 40 40 1 1 U X NC@1 7 -500 -800 200 R 40 40 1 1 U X OUTA 13 500 300 200 L 40 40 1 1 O X OUTB 9 500 -300 200 L 40 40 1 1 O X REFA 14 500 100 200 L 40 40 1 1 P X REFB 8 500 -500 200 L 40 40 1 1 P X SENSEA 12 500 500 200 L 40 40 1 1 P X SENSEB 10 500 -100 200 L 40 40 1 1 P X V+ 11 500 -600 200 L 40 40 1 1 W X V- 4 500 -800 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2137P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2137P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2134 F0 "IC" -500 625 50 H V L B F1 "INA2137P" -500 -1000 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 0 200 0 250 P 2 1 0 0 0 250 0 350 P 2 1 0 0 0 350 0 400 P 2 1 0 0 0 400 200 300 P 2 1 0 0 200 300 0 200 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 100 475 100 500 P 2 1 0 0 100 500 100 525 P 2 1 0 0 100 525 200 525 P 2 1 0 0 200 525 200 500 P 2 1 0 0 200 500 200 475 P 2 1 0 0 200 475 100 475 P 2 1 0 0 0 350 -50 350 P 2 1 0 0 -100 125 -100 100 P 2 1 0 0 -100 100 -100 75 P 2 1 0 0 -100 75 -200 75 P 2 1 0 0 -200 75 -200 100 P 2 1 0 0 -200 100 -200 125 P 2 1 0 0 -200 125 -100 125 P 2 1 0 0 100 125 100 100 P 2 1 0 0 100 100 100 75 P 2 1 0 0 100 75 200 75 P 2 1 0 0 200 75 200 100 P 2 1 0 0 200 100 200 125 P 2 1 0 0 200 125 100 125 P 2 1 0 0 -50 350 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 -50 500 100 500 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -50 250 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -50 100 100 100 P 2 1 0 0 12 350 37 350 P 2 1 0 0 12 250 37 250 P 2 1 0 0 25 262 25 237 P 2 1 0 0 -300 500 -200 500 P 2 1 0 0 300 500 200 500 P 2 1 0 0 200 300 300 300 P 2 1 0 0 300 100 200 100 P 2 1 0 0 -300 100 -200 100 P 2 1 0 0 -300 -900 300 -900 P 2 1 0 0 300 -900 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -900 P 2 1 0 0 0 -400 0 -350 P 2 1 0 0 0 -350 0 -250 P 2 1 0 0 0 -250 0 -200 P 2 1 0 0 0 -200 200 -300 P 2 1 0 0 200 -300 0 -400 P 2 1 0 0 -100 -125 -100 -100 P 2 1 0 0 -100 -100 -100 -75 P 2 1 0 0 -100 -75 -200 -75 P 2 1 0 0 -200 -75 -200 -100 P 2 1 0 0 -200 -100 -200 -125 P 2 1 0 0 -200 -125 -100 -125 P 2 1 0 0 100 -125 100 -100 P 2 1 0 0 100 -100 100 -75 P 2 1 0 0 100 -75 200 -75 P 2 1 0 0 200 -75 200 -100 P 2 1 0 0 200 -100 200 -125 P 2 1 0 0 200 -125 100 -125 P 2 1 0 0 0 -250 -50 -250 P 2 1 0 0 -100 -475 -100 -500 P 2 1 0 0 -100 -500 -100 -525 P 2 1 0 0 -100 -525 -200 -525 P 2 1 0 0 -200 -525 -200 -500 P 2 1 0 0 -200 -500 -200 -475 P 2 1 0 0 -200 -475 -100 -475 P 2 1 0 0 100 -475 100 -500 P 2 1 0 0 100 -500 100 -525 P 2 1 0 0 100 -525 200 -525 P 2 1 0 0 200 -525 200 -500 P 2 1 0 0 200 -500 200 -475 P 2 1 0 0 200 -475 100 -475 P 2 1 0 0 -50 -250 -50 -100 P 2 1 0 0 -50 -100 -100 -100 P 2 1 0 0 -50 -100 100 -100 P 2 1 0 0 0 -350 -50 -350 P 2 1 0 0 -50 -350 -50 -500 P 2 1 0 0 -50 -500 -100 -500 P 2 1 0 0 -50 -500 100 -500 P 2 1 0 0 12 -250 37 -250 P 2 1 0 0 12 -350 37 -350 P 2 1 0 0 25 -337 25 -362 P 2 1 0 0 -300 -100 -200 -100 P 2 1 0 0 300 -100 200 -100 P 2 1 0 0 200 -300 300 -300 P 2 1 0 0 300 -500 200 -500 P 2 1 0 0 -300 -500 -200 -500 C -50 500 12 1 1 0 N C -50 100 12 1 1 0 N C -50 -100 12 1 1 0 N C -50 -500 12 1 1 0 N X +INA 3 -500 100 200 R 40 40 1 1 I X +INB 5 -500 -500 200 R 40 40 1 1 I X -INA 2 -500 500 200 R 40 40 1 1 I X -INB 6 -500 -100 200 R 40 40 1 1 I X NC 1 -500 -700 200 R 40 40 1 1 U X NC@1 7 -500 -800 200 R 40 40 1 1 U X OUTA 13 500 300 200 L 40 40 1 1 O X OUTB 9 500 -300 200 L 40 40 1 1 O X REFA 14 500 100 200 L 40 40 1 1 P X REFB 8 500 -500 200 L 40 40 1 1 P X SENSEA 12 500 500 200 L 40 40 1 1 P X SENSEB 10 500 -100 200 L 40 40 1 1 P X V+ 11 500 -600 200 L 40 40 1 1 W X V- 4 500 -800 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2137U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2137U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2134 F0 "IC" -500 625 50 H V L B F1 "INA2137U" -500 -1000 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 0 200 0 250 P 2 1 0 0 0 250 0 350 P 2 1 0 0 0 350 0 400 P 2 1 0 0 0 400 200 300 P 2 1 0 0 200 300 0 200 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 100 475 100 500 P 2 1 0 0 100 500 100 525 P 2 1 0 0 100 525 200 525 P 2 1 0 0 200 525 200 500 P 2 1 0 0 200 500 200 475 P 2 1 0 0 200 475 100 475 P 2 1 0 0 0 350 -50 350 P 2 1 0 0 -100 125 -100 100 P 2 1 0 0 -100 100 -100 75 P 2 1 0 0 -100 75 -200 75 P 2 1 0 0 -200 75 -200 100 P 2 1 0 0 -200 100 -200 125 P 2 1 0 0 -200 125 -100 125 P 2 1 0 0 100 125 100 100 P 2 1 0 0 100 100 100 75 P 2 1 0 0 100 75 200 75 P 2 1 0 0 200 75 200 100 P 2 1 0 0 200 100 200 125 P 2 1 0 0 200 125 100 125 P 2 1 0 0 -50 350 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 -50 500 100 500 P 2 1 0 0 0 250 -50 250 P 2 1 0 0 -50 250 -50 100 P 2 1 0 0 -50 100 -100 100 P 2 1 0 0 -50 100 100 100 P 2 1 0 0 12 350 37 350 P 2 1 0 0 12 250 37 250 P 2 1 0 0 25 262 25 237 P 2 1 0 0 -300 500 -200 500 P 2 1 0 0 300 500 200 500 P 2 1 0 0 200 300 300 300 P 2 1 0 0 300 100 200 100 P 2 1 0 0 -300 100 -200 100 P 2 1 0 0 -300 -900 300 -900 P 2 1 0 0 300 -900 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -900 P 2 1 0 0 0 -400 0 -350 P 2 1 0 0 0 -350 0 -250 P 2 1 0 0 0 -250 0 -200 P 2 1 0 0 0 -200 200 -300 P 2 1 0 0 200 -300 0 -400 P 2 1 0 0 -100 -125 -100 -100 P 2 1 0 0 -100 -100 -100 -75 P 2 1 0 0 -100 -75 -200 -75 P 2 1 0 0 -200 -75 -200 -100 P 2 1 0 0 -200 -100 -200 -125 P 2 1 0 0 -200 -125 -100 -125 P 2 1 0 0 100 -125 100 -100 P 2 1 0 0 100 -100 100 -75 P 2 1 0 0 100 -75 200 -75 P 2 1 0 0 200 -75 200 -100 P 2 1 0 0 200 -100 200 -125 P 2 1 0 0 200 -125 100 -125 P 2 1 0 0 0 -250 -50 -250 P 2 1 0 0 -100 -475 -100 -500 P 2 1 0 0 -100 -500 -100 -525 P 2 1 0 0 -100 -525 -200 -525 P 2 1 0 0 -200 -525 -200 -500 P 2 1 0 0 -200 -500 -200 -475 P 2 1 0 0 -200 -475 -100 -475 P 2 1 0 0 100 -475 100 -500 P 2 1 0 0 100 -500 100 -525 P 2 1 0 0 100 -525 200 -525 P 2 1 0 0 200 -525 200 -500 P 2 1 0 0 200 -500 200 -475 P 2 1 0 0 200 -475 100 -475 P 2 1 0 0 -50 -250 -50 -100 P 2 1 0 0 -50 -100 -100 -100 P 2 1 0 0 -50 -100 100 -100 P 2 1 0 0 0 -350 -50 -350 P 2 1 0 0 -50 -350 -50 -500 P 2 1 0 0 -50 -500 -100 -500 P 2 1 0 0 -50 -500 100 -500 P 2 1 0 0 12 -250 37 -250 P 2 1 0 0 12 -350 37 -350 P 2 1 0 0 25 -337 25 -362 P 2 1 0 0 -300 -100 -200 -100 P 2 1 0 0 300 -100 200 -100 P 2 1 0 0 200 -300 300 -300 P 2 1 0 0 300 -500 200 -500 P 2 1 0 0 -300 -500 -200 -500 C -50 500 12 1 1 0 N C -50 100 12 1 1 0 N C -50 -100 12 1 1 0 N C -50 -500 12 1 1 0 N X +INA 3 -500 100 200 R 40 40 1 1 I X +INB 5 -500 -500 200 R 40 40 1 1 I X -INA 2 -500 500 200 R 40 40 1 1 I X -INB 6 -500 -100 200 R 40 40 1 1 I X NC 1 -500 -700 200 R 40 40 1 1 U X NC@1 7 -500 -800 200 R 40 40 1 1 U X OUTA 13 500 300 200 L 40 40 1 1 O X OUTB 9 500 -300 200 L 40 40 1 1 O X REFA 14 500 100 200 L 40 40 1 1 P X REFB 8 500 -500 200 L 40 40 1 1 P X SENSEA 12 500 500 200 L 40 40 1 1 P X SENSEB 10 500 -100 200 L 40 40 1 1 P X V+ 11 500 -600 200 L 40 40 1 1 W X V- 4 500 -800 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: INA2141P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2141P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2141 F0 "IC" -700 925 50 H V L B F1 "INA2141P" -700 -1100 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 600 -300 650 P 2 1 0 0 -300 650 -300 750 P 2 1 0 0 -300 750 -300 800 P 2 1 0 0 -300 800 -100 700 P 2 1 0 0 -100 700 -300 600 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 0 675 0 700 P 2 1 0 0 0 700 0 725 P 2 1 0 0 0 725 100 725 P 2 1 0 0 100 725 100 700 P 2 1 0 0 100 700 100 675 P 2 1 0 0 100 675 0 675 P 2 1 0 0 -300 750 -350 750 P 2 1 0 0 300 725 300 700 P 2 1 0 0 300 700 300 675 P 2 1 0 0 300 675 200 675 P 2 1 0 0 200 675 200 700 P 2 1 0 0 200 700 200 725 P 2 1 0 0 200 725 300 725 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 300 175 P 2 1 0 0 300 175 300 200 P 2 1 0 0 300 200 300 225 P 2 1 0 0 300 225 200 225 P 2 1 0 0 -300 650 -350 650 P 2 1 0 0 -287 750 -262 750 P 2 1 0 0 -287 650 -262 650 P 2 1 0 0 -275 762 -275 737 P 2 1 0 0 -300 100 -300 150 P 2 1 0 0 -300 150 -300 250 P 2 1 0 0 -300 250 -300 300 P 2 1 0 0 -300 300 -100 200 P 2 1 0 0 -100 200 -300 100 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 0 225 P 2 1 0 0 0 225 0 200 P 2 1 0 0 0 200 0 175 P 2 1 0 0 0 175 100 175 P 2 1 0 0 -200 375 -200 400 P 2 1 0 0 -200 400 -200 425 P 2 1 0 0 -200 425 -100 425 P 2 1 0 0 -100 425 -100 400 P 2 1 0 0 -100 400 -100 375 P 2 1 0 0 -100 375 -200 375 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -300 150 -350 150 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -287 150 -262 150 P 2 1 0 0 -275 162 -275 137 P 2 1 0 0 -350 750 -350 800 P 2 1 0 0 -350 800 -700 800 P 2 1 0 0 200 400 200 450 P 2 1 0 0 200 450 200 550 P 2 1 0 0 200 550 200 600 P 2 1 0 0 200 600 400 500 P 2 1 0 0 400 500 200 400 P 2 1 0 0 200 450 150 450 P 2 1 0 0 212 550 237 550 P 2 1 0 0 212 450 237 450 P 2 1 0 0 225 462 225 437 P 2 1 0 0 -100 700 -50 700 P 2 1 0 0 -50 700 0 700 P 2 1 0 0 100 700 150 700 P 2 1 0 0 150 700 200 700 P 2 1 0 0 400 500 500 500 P 2 1 0 0 -350 650 -350 600 P 2 1 0 0 -350 600 -350 500 P 2 1 0 0 -350 500 -200 500 P 2 1 0 0 -50 700 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 150 700 150 550 P 2 1 0 0 150 550 200 550 P 2 1 0 0 -200 400 -350 400 P 2 1 0 0 -350 400 -350 250 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 0 200 P 2 1 0 0 100 200 150 200 P 2 1 0 0 150 200 200 200 P 2 1 0 0 -350 150 -350 100 P 2 1 0 0 -350 100 -700 100 P 2 1 0 0 150 450 150 200 P 2 1 0 0 300 200 500 200 P 2 1 0 0 -400 575 -400 600 P 2 1 0 0 -400 600 -400 625 P 2 1 0 0 -400 625 -500 625 P 2 1 0 0 -500 625 -500 600 P 2 1 0 0 -500 600 -500 575 P 2 1 0 0 -500 575 -400 575 P 2 1 0 0 -400 275 -400 300 P 2 1 0 0 -400 300 -400 325 P 2 1 0 0 -400 325 -500 325 P 2 1 0 0 -500 325 -500 300 P 2 1 0 0 -500 300 -500 275 P 2 1 0 0 -500 275 -400 275 P 2 1 0 0 -350 300 -400 300 P 2 1 0 0 -575 500 -600 500 P 2 1 0 0 -600 500 -625 500 P 2 1 0 0 -625 500 -625 400 P 2 1 0 0 -625 400 -600 400 P 2 1 0 0 -600 400 -575 400 P 2 1 0 0 -575 400 -575 500 P 2 1 0 0 -600 300 -600 400 P 2 1 0 0 -600 600 -600 500 P 2 1 0 0 -700 600 -600 600 P 2 1 0 0 -600 600 -500 600 P 2 1 0 0 -700 300 -600 300 P 2 1 0 0 -600 300 -500 300 P 2 1 0 0 -400 600 -350 600 P 2 1 0 0 -300 -200 -300 -150 P 2 1 0 0 -300 -150 -300 -50 P 2 1 0 0 -300 -50 -300 0 P 2 1 0 0 -300 0 -100 -100 P 2 1 0 0 -100 -100 -300 -200 P 2 1 0 0 -100 -325 -100 -300 P 2 1 0 0 -100 -300 -100 -275 P 2 1 0 0 -100 -275 -200 -275 P 2 1 0 0 -200 -275 -200 -300 P 2 1 0 0 -200 -300 -200 -325 P 2 1 0 0 -200 -325 -100 -325 P 2 1 0 0 0 -125 0 -100 P 2 1 0 0 0 -100 0 -75 P 2 1 0 0 0 -75 100 -75 P 2 1 0 0 100 -75 100 -100 P 2 1 0 0 100 -100 100 -125 P 2 1 0 0 100 -125 0 -125 P 2 1 0 0 -300 -50 -350 -50 P 2 1 0 0 300 -75 300 -100 P 2 1 0 0 300 -100 300 -125 P 2 1 0 0 300 -125 200 -125 P 2 1 0 0 200 -125 200 -100 P 2 1 0 0 200 -100 200 -75 P 2 1 0 0 200 -75 300 -75 P 2 1 0 0 200 -575 200 -600 P 2 1 0 0 200 -600 200 -625 P 2 1 0 0 200 -625 300 -625 P 2 1 0 0 300 -625 300 -600 P 2 1 0 0 300 -600 300 -575 P 2 1 0 0 300 -575 200 -575 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -287 -50 -262 -50 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -275 -37 -275 -62 P 2 1 0 0 -300 -700 -300 -650 P 2 1 0 0 -300 -650 -300 -550 P 2 1 0 0 -300 -550 -300 -500 P 2 1 0 0 -300 -500 -100 -600 P 2 1 0 0 -100 -600 -300 -700 P 2 1 0 0 100 -625 100 -600 P 2 1 0 0 100 -600 100 -575 P 2 1 0 0 100 -575 0 -575 P 2 1 0 0 0 -575 0 -600 P 2 1 0 0 0 -600 0 -625 P 2 1 0 0 0 -625 100 -625 P 2 1 0 0 -200 -425 -200 -400 P 2 1 0 0 -200 -400 -200 -375 P 2 1 0 0 -200 -375 -100 -375 P 2 1 0 0 -100 -375 -100 -400 P 2 1 0 0 -100 -400 -100 -425 P 2 1 0 0 -100 -425 -200 -425 P 2 1 0 0 -300 -550 -350 -550 P 2 1 0 0 -300 -650 -350 -650 P 2 1 0 0 -287 -550 -262 -550 P 2 1 0 0 -287 -650 -262 -650 P 2 1 0 0 -275 -637 -275 -662 P 2 1 0 0 -350 -50 -350 0 P 2 1 0 0 -350 0 -700 0 P 2 1 0 0 200 -400 200 -350 P 2 1 0 0 200 -350 200 -250 P 2 1 0 0 200 -250 200 -200 P 2 1 0 0 200 -200 400 -300 P 2 1 0 0 400 -300 200 -400 P 2 1 0 0 200 -350 150 -350 P 2 1 0 0 212 -250 237 -250 P 2 1 0 0 212 -350 237 -350 P 2 1 0 0 225 -337 225 -362 P 2 1 0 0 -100 -100 -50 -100 P 2 1 0 0 -50 -100 0 -100 P 2 1 0 0 100 -100 150 -100 P 2 1 0 0 150 -100 200 -100 P 2 1 0 0 400 -300 500 -300 P 2 1 0 0 -350 -150 -350 -200 P 2 1 0 0 -350 -200 -350 -300 P 2 1 0 0 -350 -300 -200 -300 P 2 1 0 0 -50 -100 -50 -300 P 2 1 0 0 -50 -300 -100 -300 P 2 1 0 0 150 -100 150 -250 P 2 1 0 0 150 -250 200 -250 P 2 1 0 0 -200 -400 -350 -400 P 2 1 0 0 -350 -400 -350 -550 P 2 1 0 0 -100 -400 -50 -400 P 2 1 0 0 -50 -400 -50 -600 P 2 1 0 0 -50 -600 -100 -600 P 2 1 0 0 -50 -600 0 -600 P 2 1 0 0 100 -600 150 -600 P 2 1 0 0 150 -600 200 -600 P 2 1 0 0 -350 -650 -350 -700 P 2 1 0 0 -350 -700 -700 -700 P 2 1 0 0 150 -350 150 -600 P 2 1 0 0 300 -600 500 -600 P 2 1 0 0 -400 -225 -400 -200 P 2 1 0 0 -400 -200 -400 -175 P 2 1 0 0 -400 -175 -500 -175 P 2 1 0 0 -500 -175 -500 -200 P 2 1 0 0 -500 -200 -500 -225 P 2 1 0 0 -500 -225 -400 -225 P 2 1 0 0 -400 -525 -400 -500 P 2 1 0 0 -400 -500 -400 -475 P 2 1 0 0 -400 -475 -500 -475 P 2 1 0 0 -500 -475 -500 -500 P 2 1 0 0 -500 -500 -500 -525 P 2 1 0 0 -500 -525 -400 -525 P 2 1 0 0 -350 -500 -400 -500 P 2 1 0 0 -575 -300 -600 -300 P 2 1 0 0 -600 -300 -625 -300 P 2 1 0 0 -625 -300 -625 -400 P 2 1 0 0 -625 -400 -600 -400 P 2 1 0 0 -600 -400 -575 -400 P 2 1 0 0 -575 -400 -575 -300 P 2 1 0 0 -600 -500 -600 -400 P 2 1 0 0 -600 -200 -600 -300 P 2 1 0 0 -700 -200 -600 -200 P 2 1 0 0 -600 -200 -500 -200 P 2 1 0 0 -700 -500 -600 -500 P 2 1 0 0 -600 -500 -500 -500 P 2 1 0 0 -400 -200 -350 -200 P 2 1 0 0 -700 -1000 -700 900 P 2 1 0 0 -700 900 500 900 P 2 1 0 0 500 900 500 700 P 2 1 0 0 500 700 500 -100 P 2 1 0 0 500 -100 500 -1000 P 2 1 0 0 500 -1000 -700 -1000 P 2 1 0 0 500 700 300 700 P 2 1 0 0 500 -100 300 -100 C -350 600 12 1 1 0 N C -50 700 12 1 1 0 N C 150 700 12 1 1 0 N C -350 300 12 1 1 0 N C -50 200 12 1 1 0 N C 150 200 12 1 1 0 N C -600 600 12 1 1 0 N C -600 300 12 1 1 0 N C -350 -200 12 1 1 0 N C -50 -100 12 1 1 0 N C 150 -100 12 1 1 0 N C -350 -500 12 1 1 0 N C -50 -600 12 1 1 0 N C 150 -600 12 1 1 0 N C -600 -200 12 1 1 0 N C -600 -500 12 1 1 0 N X INA+ 2 -900 100 200 R 40 40 1 1 I X INA- 1 -900 800 200 R 40 40 1 1 I X INB+ 15 -900 -700 200 R 40 40 1 1 I X INB- 16 -900 0 200 R 40 40 1 1 I X JA 3 -900 600 200 R 40 40 1 1 P X JA@1 4 -900 300 200 R 40 40 1 1 P X JB 13 -900 -200 200 R 40 40 1 1 P X JB@1 14 -900 -500 200 R 40 40 1 1 P X REFA 5 700 200 200 L 40 40 1 1 I X REFB 12 700 -600 200 L 40 40 1 1 I X SENSEA 7 700 700 200 L 40 40 1 1 I X SENSEB 10 700 -100 200 L 40 40 1 1 I X V+ 9 700 -700 200 L 40 40 1 1 W X V- 8 700 -900 200 L 40 40 1 1 W X VOA 6 700 500 200 L 40 40 1 1 O X VOB 11 700 -300 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: INA2141U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF INA2141U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: INA2141 F0 "IC" -700 925 50 H V L B F1 "INA2141U" -700 -1100 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 600 -300 650 P 2 1 0 0 -300 650 -300 750 P 2 1 0 0 -300 750 -300 800 P 2 1 0 0 -300 800 -100 700 P 2 1 0 0 -100 700 -300 600 P 2 1 0 0 -100 475 -100 500 P 2 1 0 0 -100 500 -100 525 P 2 1 0 0 -100 525 -200 525 P 2 1 0 0 -200 525 -200 500 P 2 1 0 0 -200 500 -200 475 P 2 1 0 0 -200 475 -100 475 P 2 1 0 0 0 675 0 700 P 2 1 0 0 0 700 0 725 P 2 1 0 0 0 725 100 725 P 2 1 0 0 100 725 100 700 P 2 1 0 0 100 700 100 675 P 2 1 0 0 100 675 0 675 P 2 1 0 0 -300 750 -350 750 P 2 1 0 0 300 725 300 700 P 2 1 0 0 300 700 300 675 P 2 1 0 0 300 675 200 675 P 2 1 0 0 200 675 200 700 P 2 1 0 0 200 700 200 725 P 2 1 0 0 200 725 300 725 P 2 1 0 0 200 225 200 200 P 2 1 0 0 200 200 200 175 P 2 1 0 0 200 175 300 175 P 2 1 0 0 300 175 300 200 P 2 1 0 0 300 200 300 225 P 2 1 0 0 300 225 200 225 P 2 1 0 0 -300 650 -350 650 P 2 1 0 0 -287 750 -262 750 P 2 1 0 0 -287 650 -262 650 P 2 1 0 0 -275 762 -275 737 P 2 1 0 0 -300 100 -300 150 P 2 1 0 0 -300 150 -300 250 P 2 1 0 0 -300 250 -300 300 P 2 1 0 0 -300 300 -100 200 P 2 1 0 0 -100 200 -300 100 P 2 1 0 0 100 175 100 200 P 2 1 0 0 100 200 100 225 P 2 1 0 0 100 225 0 225 P 2 1 0 0 0 225 0 200 P 2 1 0 0 0 200 0 175 P 2 1 0 0 0 175 100 175 P 2 1 0 0 -200 375 -200 400 P 2 1 0 0 -200 400 -200 425 P 2 1 0 0 -200 425 -100 425 P 2 1 0 0 -100 425 -100 400 P 2 1 0 0 -100 400 -100 375 P 2 1 0 0 -100 375 -200 375 P 2 1 0 0 -300 250 -350 250 P 2 1 0 0 -300 150 -350 150 P 2 1 0 0 -287 250 -262 250 P 2 1 0 0 -287 150 -262 150 P 2 1 0 0 -275 162 -275 137 P 2 1 0 0 -350 750 -350 800 P 2 1 0 0 -350 800 -700 800 P 2 1 0 0 200 400 200 450 P 2 1 0 0 200 450 200 550 P 2 1 0 0 200 550 200 600 P 2 1 0 0 200 600 400 500 P 2 1 0 0 400 500 200 400 P 2 1 0 0 200 450 150 450 P 2 1 0 0 212 550 237 550 P 2 1 0 0 212 450 237 450 P 2 1 0 0 225 462 225 437 P 2 1 0 0 -100 700 -50 700 P 2 1 0 0 -50 700 0 700 P 2 1 0 0 100 700 150 700 P 2 1 0 0 150 700 200 700 P 2 1 0 0 400 500 500 500 P 2 1 0 0 -350 650 -350 600 P 2 1 0 0 -350 600 -350 500 P 2 1 0 0 -350 500 -200 500 P 2 1 0 0 -50 700 -50 500 P 2 1 0 0 -50 500 -100 500 P 2 1 0 0 150 700 150 550 P 2 1 0 0 150 550 200 550 P 2 1 0 0 -200 400 -350 400 P 2 1 0 0 -350 400 -350 250 P 2 1 0 0 -100 400 -50 400 P 2 1 0 0 -50 400 -50 200 P 2 1 0 0 -50 200 -100 200 P 2 1 0 0 -50 200 0 200 P 2 1 0 0 100 200 150 200 P 2 1 0 0 150 200 200 200 P 2 1 0 0 -350 150 -350 100 P 2 1 0 0 -350 100 -700 100 P 2 1 0 0 150 450 150 200 P 2 1 0 0 300 200 500 200 P 2 1 0 0 -400 575 -400 600 P 2 1 0 0 -400 600 -400 625 P 2 1 0 0 -400 625 -500 625 P 2 1 0 0 -500 625 -500 600 P 2 1 0 0 -500 600 -500 575 P 2 1 0 0 -500 575 -400 575 P 2 1 0 0 -400 275 -400 300 P 2 1 0 0 -400 300 -400 325 P 2 1 0 0 -400 325 -500 325 P 2 1 0 0 -500 325 -500 300 P 2 1 0 0 -500 300 -500 275 P 2 1 0 0 -500 275 -400 275 P 2 1 0 0 -350 300 -400 300 P 2 1 0 0 -575 500 -600 500 P 2 1 0 0 -600 500 -625 500 P 2 1 0 0 -625 500 -625 400 P 2 1 0 0 -625 400 -600 400 P 2 1 0 0 -600 400 -575 400 P 2 1 0 0 -575 400 -575 500 P 2 1 0 0 -600 300 -600 400 P 2 1 0 0 -600 600 -600 500 P 2 1 0 0 -700 600 -600 600 P 2 1 0 0 -600 600 -500 600 P 2 1 0 0 -700 300 -600 300 P 2 1 0 0 -600 300 -500 300 P 2 1 0 0 -400 600 -350 600 P 2 1 0 0 -300 -200 -300 -150 P 2 1 0 0 -300 -150 -300 -50 P 2 1 0 0 -300 -50 -300 0 P 2 1 0 0 -300 0 -100 -100 P 2 1 0 0 -100 -100 -300 -200 P 2 1 0 0 -100 -325 -100 -300 P 2 1 0 0 -100 -300 -100 -275 P 2 1 0 0 -100 -275 -200 -275 P 2 1 0 0 -200 -275 -200 -300 P 2 1 0 0 -200 -300 -200 -325 P 2 1 0 0 -200 -325 -100 -325 P 2 1 0 0 0 -125 0 -100 P 2 1 0 0 0 -100 0 -75 P 2 1 0 0 0 -75 100 -75 P 2 1 0 0 100 -75 100 -100 P 2 1 0 0 100 -100 100 -125 P 2 1 0 0 100 -125 0 -125 P 2 1 0 0 -300 -50 -350 -50 P 2 1 0 0 300 -75 300 -100 P 2 1 0 0 300 -100 300 -125 P 2 1 0 0 300 -125 200 -125 P 2 1 0 0 200 -125 200 -100 P 2 1 0 0 200 -100 200 -75 P 2 1 0 0 200 -75 300 -75 P 2 1 0 0 200 -575 200 -600 P 2 1 0 0 200 -600 200 -625 P 2 1 0 0 200 -625 300 -625 P 2 1 0 0 300 -625 300 -600 P 2 1 0 0 300 -600 300 -575 P 2 1 0 0 300 -575 200 -575 P 2 1 0 0 -300 -150 -350 -150 P 2 1 0 0 -287 -50 -262 -50 P 2 1 0 0 -287 -150 -262 -150 P 2 1 0 0 -275 -37 -275 -62 P 2 1 0 0 -300 -700 -300 -650 P 2 1 0 0 -300 -650 -300 -550 P 2 1 0 0 -300 -550 -300 -500 P 2 1 0 0 -300 -500 -100 -600 P 2 1 0 0 -100 -600 -300 -700 P 2 1 0 0 100 -625 100 -600 P 2 1 0 0 100 -600 100 -575 P 2 1 0 0 100 -575 0 -575 P 2 1 0 0 0 -575 0 -600 P 2 1 0 0 0 -600 0 -625 P 2 1 0 0 0 -625 100 -625 P 2 1 0 0 -200 -425 -200 -400 P 2 1 0 0 -200 -400 -200 -375 P 2 1 0 0 -200 -375 -100 -375 P 2 1 0 0 -100 -375 -100 -400 P 2 1 0 0 -100 -400 -100 -425 P 2 1 0 0 -100 -425 -200 -425 P 2 1 0 0 -300 -550 -350 -550 P 2 1 0 0 -300 -650 -350 -650 P 2 1 0 0 -287 -550 -262 -550 P 2 1 0 0 -287 -650 -262 -650 P 2 1 0 0 -275 -637 -275 -662 P 2 1 0 0 -350 -50 -350 0 P 2 1 0 0 -350 0 -700 0 P 2 1 0 0 200 -400 200 -350 P 2 1 0 0 200 -350 200 -250 P 2 1 0 0 200 -250 200 -200 P 2 1 0 0 200 -200 400 -300 P 2 1 0 0 400 -300 200 -400 P 2 1 0 0 200 -350 150 -350 P 2 1 0 0 212 -250 237 -250 P 2 1 0 0 212 -350 237 -350 P 2 1 0 0 225 -337 225 -362 P 2 1 0 0 -100 -100 -50 -100 P 2 1 0 0 -50 -100 0 -100 P 2 1 0 0 100 -100 150 -100 P 2 1 0 0 150 -100 200 -100 P 2 1 0 0 400 -300 500 -300 P 2 1 0 0 -350 -150 -350 -200 P 2 1 0 0 -350 -200 -350 -300 P 2 1 0 0 -350 -300 -200 -300 P 2 1 0 0 -50 -100 -50 -300 P 2 1 0 0 -50 -300 -100 -300 P 2 1 0 0 150 -100 150 -250 P 2 1 0 0 150 -250 200 -250 P 2 1 0 0 -200 -400 -350 -400 P 2 1 0 0 -350 -400 -350 -550 P 2 1 0 0 -100 -400 -50 -400 P 2 1 0 0 -50 -400 -50 -600 P 2 1 0 0 -50 -600 -100 -600 P 2 1 0 0 -50 -600 0 -600 P 2 1 0 0 100 -600 150 -600 P 2 1 0 0 150 -600 200 -600 P 2 1 0 0 -350 -650 -350 -700 P 2 1 0 0 -350 -700 -700 -700 P 2 1 0 0 150 -350 150 -600 P 2 1 0 0 300 -600 500 -600 P 2 1 0 0 -400 -225 -400 -200 P 2 1 0 0 -400 -200 -400 -175 P 2 1 0 0 -400 -175 -500 -175 P 2 1 0 0 -500 -175 -500 -200 P 2 1 0 0 -500 -200 -500 -225 P 2 1 0 0 -500 -225 -400 -225 P 2 1 0 0 -400 -525 -400 -500 P 2 1 0 0 -400 -500 -400 -475 P 2 1 0 0 -400 -475 -500 -475 P 2 1 0 0 -500 -475 -500 -500 P 2 1 0 0 -500 -500 -500 -525 P 2 1 0 0 -500 -525 -400 -525 P 2 1 0 0 -350 -500 -400 -500 P 2 1 0 0 -575 -300 -600 -300 P 2 1 0 0 -600 -300 -625 -300 P 2 1 0 0 -625 -300 -625 -400 P 2 1 0 0 -625 -400 -600 -400 P 2 1 0 0 -600 -400 -575 -400 P 2 1 0 0 -575 -400 -575 -300 P 2 1 0 0 -600 -500 -600 -400 P 2 1 0 0 -600 -200 -600 -300 P 2 1 0 0 -700 -200 -600 -200 P 2 1 0 0 -600 -200 -500 -200 P 2 1 0 0 -700 -500 -600 -500 P 2 1 0 0 -600 -500 -500 -500 P 2 1 0 0 -400 -200 -350 -200 P 2 1 0 0 -700 -1000 -700 900 P 2 1 0 0 -700 900 500 900 P 2 1 0 0 500 900 500 700 P 2 1 0 0 500 700 500 -100 P 2 1 0 0 500 -100 500 -1000 P 2 1 0 0 500 -1000 -700 -1000 P 2 1 0 0 500 700 300 700 P 2 1 0 0 500 -100 300 -100 C -350 600 12 1 1 0 N C -50 700 12 1 1 0 N C 150 700 12 1 1 0 N C -350 300 12 1 1 0 N C -50 200 12 1 1 0 N C 150 200 12 1 1 0 N C -600 600 12 1 1 0 N C -600 300 12 1 1 0 N C -350 -200 12 1 1 0 N C -50 -100 12 1 1 0 N C 150 -100 12 1 1 0 N C -350 -500 12 1 1 0 N C -50 -600 12 1 1 0 N C 150 -600 12 1 1 0 N C -600 -200 12 1 1 0 N C -600 -500 12 1 1 0 N X INA+ 2 -900 100 200 R 40 40 1 1 I X INA- 1 -900 800 200 R 40 40 1 1 I X INB+ 15 -900 -700 200 R 40 40 1 1 I X INB- 16 -900 0 200 R 40 40 1 1 I X JA 3 -900 600 200 R 40 40 1 1 P X JA@1 4 -900 300 200 R 40 40 1 1 P X JB 13 -900 -200 200 R 40 40 1 1 P X JB@1 14 -900 -500 200 R 40 40 1 1 P X REFA 5 700 200 200 L 40 40 1 1 I X REFB 12 700 -600 200 L 40 40 1 1 I X SENSEA 7 700 700 200 L 40 40 1 1 I X SENSEB 10 700 -100 200 L 40 40 1 1 I X V+ 9 700 -700 200 L 40 40 1 1 W X V- 8 700 -900 200 L 40 40 1 1 W X VOA 6 700 500 200 L 40 40 1 1 O X VOB 11 700 -300 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO122P # Package Name: DIL16/8 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO122P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO122 F0 "IC" -300 625 50 H V L B F1 "ISO122P" -300 -600 50 H V L B F2 "burr-brown-DIL16/8" 0 150 50 H I C C DRAW P 2 1 0 0 300 -500 -300 -500 P 2 1 0 0 -300 -500 -300 600 P 2 1 0 0 -300 600 300 600 P 2 1 0 0 300 600 300 -500 X +VS1 1 500 300 200 L 40 40 1 1 W X +VS2 9 500 0 200 L 40 40 1 1 W X -VS1 2 500 200 200 L 40 40 1 1 W X -VS2 10 500 -100 200 L 40 40 1 1 W X GND 8 500 -300 200 L 40 40 1 1 W X GND@1 16 500 -400 200 L 40 40 1 1 W X VIN 15 -500 500 200 R 40 40 1 1 I X VOUT 7 500 500 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO122U # Package Name: SO28-3/8 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO122U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO122 F0 "IC" -300 625 50 H V L B F1 "ISO122U" -300 -600 50 H V L B F2 "burr-brown-SO28-3/8" 0 150 50 H I C C DRAW P 2 1 0 0 300 -500 -300 -500 P 2 1 0 0 -300 -500 -300 600 P 2 1 0 0 -300 600 300 600 P 2 1 0 0 300 600 300 -500 X +VS1 1 500 300 200 L 40 40 1 1 W X +VS2 15 500 0 200 L 40 40 1 1 W X -VS1 2 500 200 200 L 40 40 1 1 W X -VS2 16 500 -100 200 L 40 40 1 1 W X GND 14 500 -300 200 L 40 40 1 1 W X GND@1 28 500 -400 200 L 40 40 1 1 W X VIN 27 -500 500 200 R 40 40 1 1 I X VOUT 13 500 500 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO124P # Package Name: DIL16/8 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO124P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO122 F0 "IC" -300 625 50 H V L B F1 "ISO124P" -300 -600 50 H V L B F2 "burr-brown-DIL16/8" 0 150 50 H I C C DRAW P 2 1 0 0 300 -500 -300 -500 P 2 1 0 0 -300 -500 -300 600 P 2 1 0 0 -300 600 300 600 P 2 1 0 0 300 600 300 -500 X +VS1 1 500 300 200 L 40 40 1 1 W X +VS2 9 500 0 200 L 40 40 1 1 W X -VS1 2 500 200 200 L 40 40 1 1 W X -VS2 10 500 -100 200 L 40 40 1 1 W X GND 8 500 -300 200 L 40 40 1 1 W X GND@1 16 500 -400 200 L 40 40 1 1 W X VIN 15 -500 500 200 R 40 40 1 1 I X VOUT 7 500 500 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO124U # Package Name: SO28-3/8 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO124U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO122 F0 "IC" -300 625 50 H V L B F1 "ISO124U" -300 -600 50 H V L B F2 "burr-brown-SO28-3/8" 0 150 50 H I C C DRAW P 2 1 0 0 300 -500 -300 -500 P 2 1 0 0 -300 -500 -300 600 P 2 1 0 0 -300 600 300 600 P 2 1 0 0 300 600 300 -500 X +VS1 1 500 300 200 L 40 40 1 1 W X +VS2 15 500 0 200 L 40 40 1 1 W X -VS1 2 500 200 200 L 40 40 1 1 W X -VS2 16 500 -100 200 L 40 40 1 1 W X GND 14 500 -300 200 L 40 40 1 1 W X GND@1 28 500 -400 200 L 40 40 1 1 W X VIN 27 -500 500 200 R 40 40 1 1 I X VOUT 13 500 500 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO130PB # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO130PB IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO130 F0 "IC" -300 625 50 H V L B F1 "ISO130PB" -300 -600 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 300 -500 -300 -500 P 2 1 0 0 -300 -500 -300 600 P 2 1 0 0 -300 600 300 600 P 2 1 0 0 300 600 300 -500 X GND1 4 500 -200 200 L 40 40 1 1 W X GND2 5 500 -400 200 L 40 40 1 1 W X IN+ 2 -500 500 200 R 40 40 1 1 I X IN- 3 -500 400 200 R 40 40 1 1 I X OUT+ 7 500 500 200 L 40 40 1 1 O X OUT- 6 500 400 200 L 40 40 1 1 O X VS1 1 500 200 200 L 40 40 1 1 W X VS2 8 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO130UB # Package Name: SO08-GW # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO130UB IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO130 F0 "IC" -300 625 50 H V L B F1 "ISO130UB" -300 -600 50 H V L B F2 "burr-brown-SO08-GW" 0 150 50 H I C C DRAW P 2 1 0 0 300 -500 -300 -500 P 2 1 0 0 -300 -500 -300 600 P 2 1 0 0 -300 600 300 600 P 2 1 0 0 300 600 300 -500 X GND1 4 500 -200 200 L 40 40 1 1 W X GND2 5 500 -400 200 L 40 40 1 1 W X IN+ 2 -500 500 200 R 40 40 1 1 I X IN- 3 -500 400 200 R 40 40 1 1 I X OUT+ 7 500 500 200 L 40 40 1 1 O X OUT- 6 500 400 200 L 40 40 1 1 O X VS1 1 500 200 200 L 40 40 1 1 W X VS2 8 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO150P # Package Name: DIL24/12 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO150P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO150 F0 "IC" -400 525 50 H V L B F1 "ISO150P" -400 -600 50 H V L B F2 "burr-brown-DIL24/12" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -500 300 -500 P 2 1 0 0 300 -500 300 500 P 2 1 0 0 300 500 -400 500 P 2 1 0 0 -400 500 -400 -500 X D1A 1 -600 400 200 R 40 40 1 1 B X D1B 12 -600 200 200 R 40 40 1 1 B X D2A 24 -600 300 200 R 40 40 1 1 B X D2B 13 -600 100 200 R 40 40 1 1 B X GA 22 500 -200 200 L 40 40 1 1 W X GB 10 500 -400 200 L 40 40 1 1 W X R/T\1A 2 -600 -100 200 R 40 40 1 1 I X R/T\1B 11 -600 -300 200 R 40 40 1 1 I X R/T\2A 23 -600 -200 200 R 40 40 1 1 I X R/T\2B 14 -600 -400 200 R 40 40 1 1 I X VSA 3 500 200 200 L 40 40 1 1 W X VSB 15 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO150U # Package Name: SO28-3/12 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO150U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO150 F0 "IC" -400 525 50 H V L B F1 "ISO150U" -400 -600 50 H V L B F2 "burr-brown-SO28-3/12" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -500 300 -500 P 2 1 0 0 300 -500 300 500 P 2 1 0 0 300 500 -400 500 P 2 1 0 0 -400 500 -400 -500 X D1A 1 -600 400 200 R 40 40 1 1 B X D1B 14 -600 200 200 R 40 40 1 1 B X D2A 28 -600 300 200 R 40 40 1 1 B X D2B 15 -600 100 200 R 40 40 1 1 B X GA 26 500 -200 200 L 40 40 1 1 W X GB 12 500 -400 200 L 40 40 1 1 W X R/T\1A 2 -600 -100 200 R 40 40 1 1 I X R/T\1B 13 -600 -300 200 R 40 40 1 1 I X R/T\2A 27 -600 -200 200 R 40 40 1 1 I X R/T\2B 16 -600 -400 200 R 40 40 1 1 I X VSA 3 500 200 200 L 40 40 1 1 W X VSB 17 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO164P # Package Name: DIL24/16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO164P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO164 F0 "IC" -400 625 50 H V L B F1 "ISO164P" -400 -700 50 H V L B F2 "burr-brown-DIL24/16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X A0 23 -600 0 200 R 40 40 1 1 P X A1 24 -600 -100 200 R 40 40 1 1 P X COM1/S1 5 -600 -300 200 R 40 40 1 1 P X COM2 10 -600 -400 200 R 40 40 1 1 P X DGND 22 600 -500 200 L 40 40 1 1 W X GND1 20 600 -300 200 L 40 40 1 1 W X GND2 12 600 -400 200 L 40 40 1 1 W X IN+ 4 -600 500 200 R 40 40 1 1 I X IN- 3 -600 400 200 R 40 40 1 1 I X OSC 21 -600 200 200 R 40 40 1 1 I X OUT 11 600 500 200 L 40 40 1 1 O X S2 14 -600 -500 200 R 40 40 1 1 P X VS1+ 1 600 300 200 L 40 40 1 1 W X VS1- 2 600 200 200 L 40 40 1 1 W X VS2+ 15 600 0 200 L 40 40 1 1 W X VS2- 13 600 -100 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO165R # Package Name: D24-3/16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO165R IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO165 F0 "IC" -400 625 50 H V L B F1 "ISO165R" -400 -800 50 H V L B F2 "burr-brown-D24-3/16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 400 -700 P 2 1 0 0 400 -700 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X COM1 23 -600 -300 200 R 40 40 1 1 P X COM2 10 -600 -400 200 R 40 40 1 1 P X FBN 2 -600 0 200 R 40 40 1 1 P X FBP 22 -600 -100 200 R 40 40 1 1 P X GND1 20 600 -500 200 L 40 40 1 1 W X GND2 12 600 -600 200 L 40 40 1 1 W X IN+ 24 -600 500 200 R 40 40 1 1 I X IN- 1 -600 400 200 R 40 40 1 1 I X OSC 21 -600 200 200 R 40 40 1 1 I X OUT 11 600 500 200 L 40 40 1 1 O X S1 5 -600 -500 200 R 40 40 1 1 P X S2 14 -600 -600 200 R 40 40 1 1 P X VS1+ 4 600 100 200 L 40 40 1 1 W X VS1- 3 600 0 200 L 40 40 1 1 W X VS2+ 15 600 -200 200 L 40 40 1 1 W X VS2- 13 600 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO166P # Package Name: D24-3/16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO166P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO166 F0 "IC" -400 625 50 H V L B F1 "ISO166P" -400 -700 50 H V L B F2 "burr-brown-D24-3/16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X +VS1 4 600 200 200 L 40 40 1 1 W X +VS2 15 600 -100 200 L 40 40 1 1 W X -VS1 3 600 100 200 L 40 40 1 1 W X -VS2 13 600 -200 200 L 40 40 1 1 W X COM1 23 -600 -200 200 R 40 40 1 1 P X COM2 10 -600 -300 200 R 40 40 1 1 P X GND1 20 600 -400 200 L 40 40 1 1 W X GND2 12 600 -500 200 L 40 40 1 1 W X IN+ 1 -600 500 200 R 40 40 1 1 I X IN- 24 -600 400 200 R 40 40 1 1 I X MOD 21 -600 0 200 R 40 40 1 1 I X OSC 22 -600 200 200 R 40 40 1 1 I X OUT 11 600 500 200 L 40 40 1 1 O X S1 5 -600 -400 200 R 40 40 1 1 P X S2 14 -600 -500 200 R 40 40 1 1 P X VOUT 2 600 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO174P # Package Name: DIL24/16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO174P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO164 F0 "IC" -400 625 50 H V L B F1 "ISO174P" -400 -700 50 H V L B F2 "burr-brown-DIL24/16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X A0 23 -600 0 200 R 40 40 1 1 P X A1 24 -600 -100 200 R 40 40 1 1 P X COM1/S1 5 -600 -300 200 R 40 40 1 1 P X COM2 10 -600 -400 200 R 40 40 1 1 P X DGND 22 600 -500 200 L 40 40 1 1 W X GND1 20 600 -300 200 L 40 40 1 1 W X GND2 12 600 -400 200 L 40 40 1 1 W X IN+ 4 -600 500 200 R 40 40 1 1 I X IN- 3 -600 400 200 R 40 40 1 1 I X OSC 21 -600 200 200 R 40 40 1 1 I X OUT 11 600 500 200 L 40 40 1 1 O X S2 14 -600 -500 200 R 40 40 1 1 P X VS1+ 1 600 300 200 L 40 40 1 1 W X VS1- 2 600 200 200 L 40 40 1 1 W X VS2+ 15 600 0 200 L 40 40 1 1 W X VS2- 13 600 -100 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO175P # Package Name: D24-3/16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO175P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO165 F0 "IC" -400 625 50 H V L B F1 "ISO175P" -400 -800 50 H V L B F2 "burr-brown-D24-3/16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -700 400 -700 P 2 1 0 0 400 -700 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -700 X COM1 23 -600 -300 200 R 40 40 1 1 P X COM2 10 -600 -400 200 R 40 40 1 1 P X FBN 2 -600 0 200 R 40 40 1 1 P X FBP 22 -600 -100 200 R 40 40 1 1 P X GND1 20 600 -500 200 L 40 40 1 1 W X GND2 12 600 -600 200 L 40 40 1 1 W X IN+ 24 -600 500 200 R 40 40 1 1 I X IN- 1 -600 400 200 R 40 40 1 1 I X OSC 21 -600 200 200 R 40 40 1 1 I X OUT 11 600 500 200 L 40 40 1 1 O X S1 5 -600 -500 200 R 40 40 1 1 P X S2 14 -600 -600 200 R 40 40 1 1 P X VS1+ 4 600 100 200 L 40 40 1 1 W X VS1- 3 600 0 200 L 40 40 1 1 W X VS2+ 15 600 -200 200 L 40 40 1 1 W X VS2- 13 600 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO176P # Package Name: D24-3/16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO176P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO166 F0 "IC" -400 625 50 H V L B F1 "ISO176P" -400 -700 50 H V L B F2 "burr-brown-D24-3/16" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -400 600 P 2 1 0 0 -400 600 -400 -600 X +VS1 4 600 200 200 L 40 40 1 1 W X +VS2 15 600 -100 200 L 40 40 1 1 W X -VS1 3 600 100 200 L 40 40 1 1 W X -VS2 13 600 -200 200 L 40 40 1 1 W X COM1 23 -600 -200 200 R 40 40 1 1 P X COM2 10 -600 -300 200 R 40 40 1 1 P X GND1 20 600 -400 200 L 40 40 1 1 W X GND2 12 600 -500 200 L 40 40 1 1 W X IN+ 1 -600 500 200 R 40 40 1 1 I X IN- 24 -600 400 200 R 40 40 1 1 I X MOD 21 -600 0 200 R 40 40 1 1 I X OSC 22 -600 200 200 R 40 40 1 1 I X OUT 11 600 500 200 L 40 40 1 1 O X S1 5 -600 -400 200 R 40 40 1 1 P X S2 14 -600 -500 200 R 40 40 1 1 P X VOUT 2 600 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: ISO212P # Package Name: ZZ326 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF ISO212P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: ISO212 F0 "IC" -400 625 50 H V L B F1 "ISO212P" -400 -800 50 H V L B F2 "burr-brown-ZZ326" 0 150 50 H I C C DRAW P 2 1 0 0 400 -700 -400 -700 P 2 1 0 0 -400 -700 -400 600 P 2 1 0 0 -400 600 400 600 P 2 1 0 0 400 600 400 -700 X +I/P 1 -600 500 200 R 40 40 1 1 I X +VSS1 6 600 0 200 L 40 40 1 1 O X -I/P 3 -600 400 200 R 40 40 1 1 I X -VSS1 5 600 -100 200 L 40 40 1 1 O X CLKIN 35 -600 200 200 R 40 40 1 1 I X CLKOUT 34 600 200 200 L 40 40 1 1 O X COM1 2 600 -500 200 L 40 40 1 1 W X COM2 32 600 -600 200 L 40 40 1 1 W X FB 4 -600 -300 200 R 40 40 1 1 P X O/PHIGH 38 600 500 200 L 40 40 1 1 O X O/PLOW 37 600 400 200 L 40 40 1 1 O X OFFA 7 -600 0 200 R 40 40 1 1 P X OFFA@1 8 -600 -100 200 R 40 40 1 1 P X VCC 31 600 -300 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: ISO485P # Package Name: DIL24-3/12 # Dev Tech: '' # Dev Prefix: IC # Gate count = 3 # DEF ISO485P IC 0 40 Y Y 3 L N # Gate Name: A # Symbol Name: PWRN F0 "IC" -25 -25 50 H V L B F1 "ISO485P" 0 0 50 H V L B F2 "burr-brown-DIL24-3/12" 0 150 50 H I C C DRAW T 1 50 -155 50 0 1 0 GND T 1 50 175 50 0 1 0 VCC X GND 22 0 -300 200 U 40 40 1 1 W X VCC 3 0 300 200 D 40 40 1 1 W # Gate Name: B # Symbol Name: PWR2 T 1 155 -155 50 0 2 0 GND T 1 75 175 50 0 2 0 VCC X GND@1 11 0 -300 200 U 40 40 2 1 W X GND@2 14 100 -300 200 U 40 40 2 1 W X VCC 15 0 300 200 D 40 40 2 1 W # Gate Name: G # Symbol Name: ISO485P P 2 3 0 0 -700 1000 700 1000 P 2 3 0 0 700 1000 700 -1000 P 2 3 0 0 700 -1000 -700 -1000 P 2 3 0 0 -700 -1000 -700 1000 P 2 3 0 0 500 525 100 300 P 2 3 0 0 100 300 500 75 P 2 3 0 0 500 75 500 400 P 2 3 0 0 500 400 500 525 P 2 3 0 0 -100 500 -200 450 P 2 3 0 0 -200 450 -500 300 P 2 3 0 0 -500 300 -100 100 P 2 3 0 0 -100 100 -100 300 P 2 3 0 0 -100 300 -100 500 P 2 3 0 0 -500 -400 -300 -300 P 2 3 0 0 -300 -300 -100 -200 P 2 3 0 0 -100 -200 -500 0 P 2 3 0 0 -500 0 -500 -200 P 2 3 0 0 -500 -200 -500 -400 A -500 700 200 -899 899 3 1 0 N -500 500 -500 900 P 2 3 0 0 -330 800 -500 800 P 2 3 0 0 -330 600 -500 600 P 2 3 0 0 -500 900 -500 600 P 2 3 0 0 -500 600 -500 500 P 2 3 0 0 -500 600 -600 600 P 2 3 0 0 -600 600 -600 -450 P 2 3 0 0 -600 -450 -600 -700 P 2 3 0 0 -600 -450 -300 -450 P 2 3 0 0 -300 -450 -300 -300 P 2 3 0 0 100 -400 300 -300 P 2 3 0 0 300 -300 500 -200 P 2 3 0 0 500 -200 100 0 P 2 3 0 0 100 0 100 -200 P 2 3 0 0 100 -200 100 -400 P 2 3 0 0 500 -50 500 -100 P 2 3 0 0 500 -100 500 -300 P 2 3 0 0 500 -300 500 -350 P 2 3 0 0 500 -100 600 -100 P 2 3 0 0 600 -100 600 200 P 2 3 0 0 500 -300 650 -300 P 2 3 0 0 650 -300 650 400 P 2 3 0 0 -500 -900 -100 -700 P 2 3 0 0 -100 -700 -500 -500 P 2 3 0 0 -500 -500 -500 -700 P 2 3 0 0 -500 -700 -500 -900 P 2 3 0 0 -100 -700 300 -700 P 2 3 0 0 300 -700 300 -300 P 2 3 0 0 -300 700 -200 700 P 2 3 0 0 -200 700 -200 450 P 2 3 0 0 100 300 -100 300 P 2 3 0 0 -100 -200 100 -200 P 2 3 0 0 -580 800 -710 800 P 2 3 0 0 580 200 710 200 P 2 3 0 0 710 400 500 400 P 2 3 0 0 -710 -700 -500 -700 P 2 3 0 0 -710 300 -490 300 P 2 3 0 0 -710 -200 -500 -200 C -540 800 40 3 1 0 N C 540 200 40 3 1 0 N C 600 200 14 3 1 0 N C 650 400 14 3 1 0 N C -600 -450 14 3 1 0 N C -600 -700 14 3 1 0 N T 0 -420 -200 60 0 3 0 D T 0 -390 -690 60 0 3 0 DE T 0 -340 300 60 0 3 0 R T 0 430 400 60 0 3 0 A T 0 430 200 60 0 3 0 B X A 12 800 400 100 L 40 40 3 1 B X B 13 800 200 100 L 40 40 3 1 B X D 24 -800 -200 100 R 40 40 3 1 O X DE 23 -800 -700 100 R 40 40 3 1 I X NC 10 800 -700 100 L 40 40 3 1 U X R 1 -800 300 100 R 40 40 3 1 I X RE 2 -800 800 100 R 40 40 3 1 I ENDDRAW ENDDEF # # Dev Name: IVC102U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF IVC102U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: IVC102 F0 "IC" -300 725 50 H V L B F1 "IVC102U" -300 -700 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 -600 X -IN 3 -500 500 200 R 40 40 1 1 I X AGND 1 500 -300 200 L 40 40 1 1 W X C1 4 -500 -300 200 R 40 40 1 1 P X C2 5 -500 -400 200 R 40 40 1 1 P X C3 6 -500 -500 200 R 40 40 1 1 P X DGND 13 500 -500 200 L 40 40 1 1 W X IN 2 -500 600 200 R 40 40 1 1 I X NC 7 -500 300 200 R 40 40 1 1 U X NC@1 8 -500 200 200 R 40 40 1 1 U X S1 11 -500 0 200 R 40 40 1 1 I X S2 12 -500 -100 200 R 40 40 1 1 I X V+ 14 500 100 200 L 40 40 1 1 W X V- 9 500 -100 200 L 40 40 1 1 W X VOUT 10 500 600 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: MPC506AP # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC506AP IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC506 F0 "IC" -400 1225 50 H V L B F1 "MPC506AP" -400 -1300 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1200 P 2 1 0 0 300 1200 -400 1200 P 2 1 0 0 -400 1200 -400 -1200 X +V 1 500 -700 200 L 40 40 1 1 W X -V 27 500 -900 200 L 40 40 1 1 W X A0 17 -600 -600 200 R 40 40 1 1 I X A1 16 -600 -700 200 R 40 40 1 1 I X A2 15 -600 -800 200 R 40 40 1 1 I X A3 14 -600 -900 200 R 40 40 1 1 I X ENABLE 18 -600 -1100 200 R 40 40 1 1 I X GND 12 500 -1100 200 L 40 40 1 1 W X IN1 19 -600 1100 200 R 40 40 1 1 I X IN2 20 -600 1000 200 R 40 40 1 1 I X IN3 21 -600 900 200 R 40 40 1 1 I X IN4 22 -600 800 200 R 40 40 1 1 I X IN5 23 -600 700 200 R 40 40 1 1 I X IN6 24 -600 600 200 R 40 40 1 1 I X IN7 25 -600 500 200 R 40 40 1 1 I X IN8 26 -600 400 200 R 40 40 1 1 I X IN9 11 -600 300 200 R 40 40 1 1 I X IN10 10 -600 200 200 R 40 40 1 1 I X IN11 9 -600 100 200 R 40 40 1 1 I X IN12 8 -600 0 200 R 40 40 1 1 I X IN13 7 -600 -100 200 R 40 40 1 1 I X IN14 6 -600 -200 200 R 40 40 1 1 I X IN15 5 -600 -300 200 R 40 40 1 1 I X IN16 4 -600 -400 200 R 40 40 1 1 I X NC 2 500 700 200 L 40 40 1 1 U X NC@1 3 500 600 200 L 40 40 1 1 U X OUT 28 500 1100 200 L 40 40 1 1 O X VREF 13 500 900 200 L 40 40 1 1 B ENDDRAW ENDDEF # # Dev Name: MPC506AU # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC506AU IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC506 F0 "IC" -400 1225 50 H V L B F1 "MPC506AU" -400 -1300 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1200 P 2 1 0 0 300 1200 -400 1200 P 2 1 0 0 -400 1200 -400 -1200 X +V 1 500 -700 200 L 40 40 1 1 W X -V 27 500 -900 200 L 40 40 1 1 W X A0 17 -600 -600 200 R 40 40 1 1 I X A1 16 -600 -700 200 R 40 40 1 1 I X A2 15 -600 -800 200 R 40 40 1 1 I X A3 14 -600 -900 200 R 40 40 1 1 I X ENABLE 18 -600 -1100 200 R 40 40 1 1 I X GND 12 500 -1100 200 L 40 40 1 1 W X IN1 19 -600 1100 200 R 40 40 1 1 I X IN2 20 -600 1000 200 R 40 40 1 1 I X IN3 21 -600 900 200 R 40 40 1 1 I X IN4 22 -600 800 200 R 40 40 1 1 I X IN5 23 -600 700 200 R 40 40 1 1 I X IN6 24 -600 600 200 R 40 40 1 1 I X IN7 25 -600 500 200 R 40 40 1 1 I X IN8 26 -600 400 200 R 40 40 1 1 I X IN9 11 -600 300 200 R 40 40 1 1 I X IN10 10 -600 200 200 R 40 40 1 1 I X IN11 9 -600 100 200 R 40 40 1 1 I X IN12 8 -600 0 200 R 40 40 1 1 I X IN13 7 -600 -100 200 R 40 40 1 1 I X IN14 6 -600 -200 200 R 40 40 1 1 I X IN15 5 -600 -300 200 R 40 40 1 1 I X IN16 4 -600 -400 200 R 40 40 1 1 I X NC 2 500 700 200 L 40 40 1 1 U X NC@1 3 500 600 200 L 40 40 1 1 U X OUT 28 500 1100 200 L 40 40 1 1 O X VREF 13 500 900 200 L 40 40 1 1 B ENDDRAW ENDDEF # # Dev Name: MPC507AP # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC507AP IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC507 F0 "IC" -400 1225 50 H V L B F1 "MPC507AP" -400 -1287 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1200 P 2 1 0 0 300 1200 -400 1200 P 2 1 0 0 -400 1200 -400 -1200 X +V 1 500 -700 200 L 40 40 1 1 W X -V 27 500 -900 200 L 40 40 1 1 W X A0 17 -600 -700 200 R 40 40 1 1 I X A1 16 -600 -800 200 R 40 40 1 1 I X A2 15 -600 -900 200 R 40 40 1 1 I X ENABLE 18 -600 -1100 200 R 40 40 1 1 I X GND 12 500 -1100 200 L 40 40 1 1 W X IN1A 19 -600 1100 200 R 40 40 1 1 I X IN1B 11 -600 200 200 R 40 40 1 1 I X IN2A 20 -600 1000 200 R 40 40 1 1 I X IN2B 10 -600 100 200 R 40 40 1 1 I X IN3A 21 -600 900 200 R 40 40 1 1 I X IN3B 9 -600 0 200 R 40 40 1 1 I X IN4A 22 -600 800 200 R 40 40 1 1 I X IN4B 8 -600 -100 200 R 40 40 1 1 I X IN5A 23 -600 700 200 R 40 40 1 1 I X IN5B 7 -600 -200 200 R 40 40 1 1 I X IN6A 24 -600 600 200 R 40 40 1 1 I X IN6B 6 -600 -300 200 R 40 40 1 1 I X IN7A 25 -600 500 200 R 40 40 1 1 I X IN7B 5 -600 -400 200 R 40 40 1 1 I X IN8A 26 -600 400 200 R 40 40 1 1 I X IN8B 4 -600 -500 200 R 40 40 1 1 I X NC 3 500 500 200 L 40 40 1 1 U X NC@1 14 500 400 200 L 40 40 1 1 U X OUTA 28 500 1100 200 L 40 40 1 1 O X OUTB 2 500 900 200 L 40 40 1 1 O X VREF 13 500 700 200 L 40 40 1 1 B ENDDRAW ENDDEF # # Dev Name: MPC507AU # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC507AU IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC507 F0 "IC" -400 1225 50 H V L B F1 "MPC507AU" -400 -1287 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -1200 300 -1200 P 2 1 0 0 300 -1200 300 1200 P 2 1 0 0 300 1200 -400 1200 P 2 1 0 0 -400 1200 -400 -1200 X +V 1 500 -700 200 L 40 40 1 1 W X -V 27 500 -900 200 L 40 40 1 1 W X A0 17 -600 -700 200 R 40 40 1 1 I X A1 16 -600 -800 200 R 40 40 1 1 I X A2 15 -600 -900 200 R 40 40 1 1 I X ENABLE 18 -600 -1100 200 R 40 40 1 1 I X GND 12 500 -1100 200 L 40 40 1 1 W X IN1A 19 -600 1100 200 R 40 40 1 1 I X IN1B 11 -600 200 200 R 40 40 1 1 I X IN2A 20 -600 1000 200 R 40 40 1 1 I X IN2B 10 -600 100 200 R 40 40 1 1 I X IN3A 21 -600 900 200 R 40 40 1 1 I X IN3B 9 -600 0 200 R 40 40 1 1 I X IN4A 22 -600 800 200 R 40 40 1 1 I X IN4B 8 -600 -100 200 R 40 40 1 1 I X IN5A 23 -600 700 200 R 40 40 1 1 I X IN5B 7 -600 -200 200 R 40 40 1 1 I X IN6A 24 -600 600 200 R 40 40 1 1 I X IN6B 6 -600 -300 200 R 40 40 1 1 I X IN7A 25 -600 500 200 R 40 40 1 1 I X IN7B 5 -600 -400 200 R 40 40 1 1 I X IN8A 26 -600 400 200 R 40 40 1 1 I X IN8B 4 -600 -500 200 R 40 40 1 1 I X NC 3 500 500 200 L 40 40 1 1 U X NC@1 14 500 400 200 L 40 40 1 1 U X OUTA 28 500 1100 200 L 40 40 1 1 O X OUTB 2 500 900 200 L 40 40 1 1 O X VREF 13 500 700 200 L 40 40 1 1 B ENDDRAW ENDDEF # # Dev Name: MPC508AP # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC508AP IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC508 F0 "IC" -300 825 50 H V L B F1 "MPC508AP" -300 -800 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 800 P 2 1 0 0 300 800 -300 800 P 2 1 0 0 -300 800 -300 -700 X +V 13 500 -200 200 L 40 40 1 1 W X -V 3 500 -400 200 L 40 40 1 1 W X A0 1 -500 -200 200 R 40 40 1 1 I X A1 16 -500 -300 200 R 40 40 1 1 I X A2 15 -500 -400 200 R 40 40 1 1 I X EN 2 -500 -600 200 R 40 40 1 1 I X GND 14 500 -600 200 L 40 40 1 1 W X IN1 4 -500 700 200 R 40 40 1 1 I X IN2 5 -500 600 200 R 40 40 1 1 I X IN3 6 -500 500 200 R 40 40 1 1 I X IN4 7 -500 400 200 R 40 40 1 1 I X IN5 12 -500 300 200 R 40 40 1 1 I X IN6 11 -500 200 200 R 40 40 1 1 I X IN7 10 -500 100 200 R 40 40 1 1 I X IN8 9 -500 0 200 R 40 40 1 1 I X OUT 8 500 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: MPC508AU # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC508AU IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC508 F0 "IC" -300 825 50 H V L B F1 "MPC508AU" -300 -800 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -700 300 -700 P 2 1 0 0 300 -700 300 800 P 2 1 0 0 300 800 -300 800 P 2 1 0 0 -300 800 -300 -700 X +V 13 500 -200 200 L 40 40 1 1 W X -V 3 500 -400 200 L 40 40 1 1 W X A0 1 -500 -200 200 R 40 40 1 1 I X A1 16 -500 -300 200 R 40 40 1 1 I X A2 15 -500 -400 200 R 40 40 1 1 I X EN 2 -500 -600 200 R 40 40 1 1 I X GND 14 500 -600 200 L 40 40 1 1 W X IN1 4 -500 700 200 R 40 40 1 1 I X IN2 5 -500 600 200 R 40 40 1 1 I X IN3 6 -500 500 200 R 40 40 1 1 I X IN4 7 -500 400 200 R 40 40 1 1 I X IN5 12 -500 300 200 R 40 40 1 1 I X IN6 11 -500 200 200 R 40 40 1 1 I X IN7 10 -500 100 200 R 40 40 1 1 I X IN8 9 -500 0 200 R 40 40 1 1 I X OUT 8 500 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: MPC509AP # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC509AP IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC509 F0 "IC" -300 725 50 H V L B F1 "MPC509AP" -300 -900 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -800 400 -800 P 2 1 0 0 400 -800 400 700 P 2 1 0 0 400 700 -300 700 P 2 1 0 0 -300 700 -300 -800 X +V 14 600 -300 200 L 40 40 1 1 W X -V 3 600 -500 200 L 40 40 1 1 W X A0 1 -500 -400 200 R 40 40 1 1 I X A1 16 -500 -500 200 R 40 40 1 1 I X EN 2 -500 -700 200 R 40 40 1 1 I X GND 15 600 -700 200 L 40 40 1 1 W X IN1A 4 -500 600 200 R 40 40 1 1 I X IN1B 13 -500 100 200 R 40 40 1 1 I X IN2A 5 -500 500 200 R 40 40 1 1 I X IN2B 12 -500 0 200 R 40 40 1 1 I X IN3A 6 -500 400 200 R 40 40 1 1 I X IN3B 11 -500 -100 200 R 40 40 1 1 I X IN4A 7 -500 300 200 R 40 40 1 1 I X IN4B 10 -500 -200 200 R 40 40 1 1 I X OUTA 8 600 600 200 L 40 40 1 1 O X OUTB 9 600 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: MPC509AU # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF MPC509AU IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: MPC509 F0 "IC" -300 725 50 H V L B F1 "MPC509AU" -300 -900 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -800 400 -800 P 2 1 0 0 400 -800 400 700 P 2 1 0 0 400 700 -300 700 P 2 1 0 0 -300 700 -300 -800 X +V 14 600 -300 200 L 40 40 1 1 W X -V 3 600 -500 200 L 40 40 1 1 W X A0 1 -500 -400 200 R 40 40 1 1 I X A1 16 -500 -500 200 R 40 40 1 1 I X EN 2 -500 -700 200 R 40 40 1 1 I X GND 15 600 -700 200 L 40 40 1 1 W X IN1A 4 -500 600 200 R 40 40 1 1 I X IN1B 13 -500 100 200 R 40 40 1 1 I X IN2A 5 -500 500 200 R 40 40 1 1 I X IN2B 12 -500 0 200 R 40 40 1 1 I X IN3A 6 -500 400 200 R 40 40 1 1 I X IN3B 11 -500 -100 200 R 40 40 1 1 I X IN4A 7 -500 300 200 R 40 40 1 1 I X IN4B 10 -500 -200 200 R 40 40 1 1 I X OUTA 8 600 600 200 L 40 40 1 1 O X OUTB 9 600 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA77P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA77P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA77P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA124P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA124P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIMSUB F0 "IC" 100 225 50 H V L B F1 "OPA124P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 100 103 52 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 T 1 109 164 32 0 1 0 SUBS X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X SUBS 8 300 100 100 L 40 40 1 1 P X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA124U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA124U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: SUBS F0 "IC" 100 225 50 H V L B F1 "OPA124U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 100 103 52 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 109 164 32 0 1 0 SUBS X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X SUBS 8 300 100 100 L 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA129P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA129P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: SUBS F0 "IC" 100 225 50 H V L B F1 "OPA129P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 100 103 52 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 109 164 32 0 1 0 SUBS X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X SUBS 8 300 100 100 L 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 5 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA129U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA129U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: SUBS F0 "IC" 100 225 50 H V L B F1 "OPA129U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 100 103 52 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 109 164 32 0 1 0 SUBS X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X SUBS 8 300 100 100 L 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 5 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA130P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA130P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA130P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA130U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA130U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA130U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA131P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA131P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA131P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA131U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA131U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA131U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA132P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA132P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA132P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA132U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA132U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA132U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA134P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA134P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA134P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA134U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA134U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA134U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA177P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA177P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA177P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA177S # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA177S IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA177S" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 8 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA234P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA234P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA234P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA234U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA234U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA234U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA237N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA237N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA237N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA237U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA237U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA237U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA241P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA241P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA241P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA241U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA241U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA241U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA251P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA251P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA251P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA251U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA251U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA251U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA336N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA336N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA336N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA336P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA336P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA336P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA336U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA336U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA336U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA340N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA340N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA340N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA340P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA340P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA340P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA340U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA340U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA340U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA544T # Package Name: TO220-G5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA544T IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA544T" 100 -200 50 H V L B F2 "burr-brown-TO220-G5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 1 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 4 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 3 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA544T1 # Package Name: TO220-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA544T1 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA544T1" 100 -200 50 H V L B F2 "burr-brown-TO220-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 1 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 4 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 3 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA547F # Package Name: DD-7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA547F IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OPA548 F0 "IC" 100 125 50 H V L B F1 "OPA547F" 100 -300 50 H V L B F2 "burr-brown-DD-7" 0 150 50 H I C C DRAW P 2 1 0 0 -150 25 -150 -25 P 2 1 0 0 -175 0 -125 0 P 2 1 0 0 -175 -200 -125 -200 P 2 1 0 0 -200 100 -200 -300 P 2 1 0 0 -100 100 -100 53 P 2 1 0 0 0 100 0 3 P 2 1 0 0 106 -48 200 0 P 2 1 0 0 -200 100 200 -100 P 2 1 0 0 -100 -253 -100 -300 P 2 1 0 0 -200 -300 200 -100 T 1 -66 107 32 0 1 0 V+ T 1 -66 -293 32 0 1 0 V- T 1 34 73 32 0 1 0 E/S T 1 109 64 32 0 1 0 ILIM X +IN 1 -300 0 100 R 40 40 1 1 I X -IN 2 -300 -200 100 R 40 40 1 1 I X E/S 7 0 200 100 D 40 40 1 1 B X ILIM 3 300 0 100 L 40 40 1 1 I X OUT 6 300 -100 100 L 40 40 1 1 O X V+ 5 -100 200 100 D 40 40 1 1 W X V- 4 -100 -400 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA547T # Package Name: TO220-7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA547T IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OPA548 F0 "IC" 100 125 50 H V L B F1 "OPA547T" 100 -300 50 H V L B F2 "burr-brown-TO220-7" 0 150 50 H I C C DRAW P 2 1 0 0 -150 25 -150 -25 P 2 1 0 0 -175 0 -125 0 P 2 1 0 0 -175 -200 -125 -200 P 2 1 0 0 -200 100 -200 -300 P 2 1 0 0 -100 100 -100 53 P 2 1 0 0 0 100 0 3 P 2 1 0 0 106 -48 200 0 P 2 1 0 0 -200 100 200 -100 P 2 1 0 0 -100 -253 -100 -300 P 2 1 0 0 -200 -300 200 -100 T 1 -66 107 32 0 1 0 V+ T 1 -66 -293 32 0 1 0 V- T 1 34 73 32 0 1 0 E/S T 1 109 64 32 0 1 0 ILIM X +IN 1 -300 0 100 R 40 40 1 1 I X -IN 2 -300 -200 100 R 40 40 1 1 I X E/S 7 0 200 100 D 40 40 1 1 B X ILIM 3 300 0 100 L 40 40 1 1 I X OUT 6 300 -100 100 L 40 40 1 1 O X V+ 5 -100 200 100 D 40 40 1 1 W X V- 4 -100 -400 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA548F # Package Name: DD-7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA548F IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OPA548 F0 "IC" 100 125 50 H V L B F1 "OPA548F" 100 -300 50 H V L B F2 "burr-brown-DD-7" 0 150 50 H I C C DRAW P 2 1 0 0 -150 25 -150 -25 P 2 1 0 0 -175 0 -125 0 P 2 1 0 0 -175 -200 -125 -200 P 2 1 0 0 -200 100 -200 -300 P 2 1 0 0 -100 100 -100 53 P 2 1 0 0 0 100 0 3 P 2 1 0 0 106 -48 200 0 P 2 1 0 0 -200 100 200 -100 P 2 1 0 0 -100 -253 -100 -300 P 2 1 0 0 -200 -300 200 -100 T 1 -66 107 32 0 1 0 V+ T 1 -66 -293 32 0 1 0 V- T 1 34 73 32 0 1 0 E/S T 1 109 64 32 0 1 0 ILIM X +IN 1 -300 0 100 R 40 40 1 1 I X -IN 2 -300 -200 100 R 40 40 1 1 I X E/S 7 0 200 100 D 40 40 1 1 B X ILIM 3 300 0 100 L 40 40 1 1 I X OUT 6 300 -100 100 L 40 40 1 1 O X V+ 5 -100 200 100 D 40 40 1 1 W X V- 4 -100 -400 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA548T # Package Name: TO220-7 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA548T IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OPA548 F0 "IC" 100 125 50 H V L B F1 "OPA548T" 100 -300 50 H V L B F2 "burr-brown-TO220-7" 0 150 50 H I C C DRAW P 2 1 0 0 -150 25 -150 -25 P 2 1 0 0 -175 0 -125 0 P 2 1 0 0 -175 -200 -125 -200 P 2 1 0 0 -200 100 -200 -300 P 2 1 0 0 -100 100 -100 53 P 2 1 0 0 0 100 0 3 P 2 1 0 0 106 -48 200 0 P 2 1 0 0 -200 100 200 -100 P 2 1 0 0 -100 -253 -100 -300 P 2 1 0 0 -200 -300 200 -100 T 1 -66 107 32 0 1 0 V+ T 1 -66 -293 32 0 1 0 V- T 1 34 73 32 0 1 0 E/S T 1 109 64 32 0 1 0 ILIM X +IN 1 -300 0 100 R 40 40 1 1 I X -IN 2 -300 -200 100 R 40 40 1 1 I X E/S 7 0 200 100 D 40 40 1 1 B X ILIM 3 300 0 100 L 40 40 1 1 I X OUT 6 300 -100 100 L 40 40 1 1 O X V+ 5 -100 200 100 D 40 40 1 1 W X V- 4 -100 -400 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA627P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA627P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA627P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA627U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA627U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA627U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA627M # Package Name: TO99 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA627M IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIMCAS F0 "IC" 100 225 50 H V L B F1 "OPA627M" 100 -200 50 H V L B F2 "burr-brown-TO99" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 100 103 52 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 -170 32 0 1 0 TRIM2 T 1 109 164 32 0 1 0 CASE T 1 34 205 32 0 1 0 TRIM1 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X CASE 8 300 100 100 L 40 40 1 1 P X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA637P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA637P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA637P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA637U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA637U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIM F0 "IC" 100 225 50 H V L B F1 "OPA637U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 205 32 0 1 0 TRIM1 T 1 34 -170 32 0 1 0 TRIM2 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA637M # Package Name: TO99 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA637M IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2TRIMCAS F0 "IC" 100 225 50 H V L B F1 "OPA637M" 100 -200 50 H V L B F2 "burr-brown-TO99" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 100 103 52 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- T 1 34 -170 32 0 1 0 TRIM2 T 1 109 164 32 0 1 0 CASE T 1 34 205 32 0 1 0 TRIM1 X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X CASE 8 300 100 100 L 40 40 1 1 P X OUT 6 300 0 100 L 40 40 1 1 O X TRIM1 1 0 300 100 D 40 40 1 1 P X TRIM2 5 0 -300 100 U 40 40 1 1 P X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA642P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA642P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2+2- F0 "IC" 100 225 50 H V L B F1 "OPA642P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 239 32 0 1 0 +VS1 T 1 -66 -211 32 0 1 0 -VS1 T 1 34 189 32 0 1 0 +VS2 T 1 34 -186 32 0 1 0 -VS2 X +IN 3 -300 100 100 R 40 40 1 1 I X +VS1 7 -100 300 100 D 40 40 1 1 W X +VS2 8 0 300 100 D 40 40 1 1 W X -IN 2 -300 -100 100 R 40 40 1 1 I X -VS1 4 -100 -300 100 U 40 40 1 1 W X -VS2 5 0 -300 100 U 40 40 1 1 W X OUT 6 300 0 100 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA642N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA642N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA642N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA642U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA642U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2+2- F0 "IC" 100 225 50 H V L B F1 "OPA642U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 239 32 0 1 0 +VS1 T 1 -66 -211 32 0 1 0 -VS1 T 1 34 189 32 0 1 0 +VS2 T 1 34 -186 32 0 1 0 -VS2 X +IN 3 -300 100 100 R 40 40 1 1 I X +VS1 7 -100 300 100 D 40 40 1 1 W X +VS2 8 0 300 100 D 40 40 1 1 W X -IN 2 -300 -100 100 R 40 40 1 1 I X -VS1 4 -100 -300 100 U 40 40 1 1 W X -VS2 5 0 -300 100 U 40 40 1 1 W X OUT 6 300 0 100 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA643P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA643P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2+2- F0 "IC" 100 225 50 H V L B F1 "OPA643P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 239 32 0 1 0 +VS1 T 1 -66 -211 32 0 1 0 -VS1 T 1 34 189 32 0 1 0 +VS2 T 1 34 -186 32 0 1 0 -VS2 X +IN 3 -300 100 100 R 40 40 1 1 I X +VS1 7 -100 300 100 D 40 40 1 1 W X +VS2 8 0 300 100 D 40 40 1 1 W X -IN 2 -300 -100 100 R 40 40 1 1 I X -VS1 4 -100 -300 100 U 40 40 1 1 W X -VS2 5 0 -300 100 U 40 40 1 1 W X OUT 6 300 0 100 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA643U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA643U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2+2- F0 "IC" 100 225 50 H V L B F1 "OPA643U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 239 32 0 1 0 +VS1 T 1 -66 -211 32 0 1 0 -VS1 T 1 34 189 32 0 1 0 +VS2 T 1 34 -186 32 0 1 0 -VS2 X +IN 3 -300 100 100 R 40 40 1 1 I X +VS1 7 -100 300 100 D 40 40 1 1 W X +VS2 8 0 300 100 D 40 40 1 1 W X -IN 2 -300 -100 100 R 40 40 1 1 I X -VS1 4 -100 -300 100 U 40 40 1 1 W X -VS2 5 0 -300 100 U 40 40 1 1 W X OUT 6 300 0 100 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA643N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA643N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA643N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA650N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA650N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA650N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA650P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA650P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA650P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA650U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA650U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA650U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA651N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA651N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA651N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA651P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA651P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA651P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA651U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA651U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA651U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA655P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA655P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2+2- F0 "IC" 100 225 50 H V L B F1 "OPA655P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 239 32 0 1 0 +VS1 T 1 -66 -211 32 0 1 0 -VS1 T 1 34 189 32 0 1 0 +VS2 T 1 34 -186 32 0 1 0 -VS2 X +IN 3 -300 100 100 R 40 40 1 1 I X +VS1 7 -100 300 100 D 40 40 1 1 W X +VS2 8 0 300 100 D 40 40 1 1 W X -IN 2 -300 -100 100 R 40 40 1 1 I X -VS1 4 -100 -300 100 U 40 40 1 1 W X -VS2 5 0 -300 100 U 40 40 1 1 W X OUT 6 300 0 100 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA655U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA655U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: 2+2- F0 "IC" 100 225 50 H V L B F1 "OPA655U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 0 199 0 103 P 2 1 0 0 0 -103 0 -200 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 239 32 0 1 0 +VS1 T 1 -66 -211 32 0 1 0 -VS1 T 1 34 189 32 0 1 0 +VS2 T 1 34 -186 32 0 1 0 -VS2 X +IN 3 -300 100 100 R 40 40 1 1 I X +VS1 7 -100 300 100 D 40 40 1 1 W X +VS2 8 0 300 100 D 40 40 1 1 W X -IN 2 -300 -100 100 R 40 40 1 1 I X -VS1 4 -100 -300 100 U 40 40 1 1 W X -VS2 5 0 -300 100 U 40 40 1 1 W X OUT 6 300 0 100 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA658N # Package Name: SOT23-5 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA658N IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA658N" 100 -200 50 H V L B F2 "burr-brown-SOT23-5" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 4 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 5 -100 300 100 D 40 40 1 1 W X V- 2 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA658P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA658P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA658P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA658U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA658U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA658U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 6 300 0 100 L 40 40 1 1 O X V+ 7 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: OPA678P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA678P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OPA678 F0 "IC" -600 825 50 H V L B F1 "OPA678P" -600 -600 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -600 -500 100 -500 P 2 1 0 0 100 -500 100 800 P 2 1 0 0 100 800 -600 800 P 2 1 0 0 -600 800 -600 -500 X +INA 1 -800 700 200 R 40 40 1 1 I X +INB 16 -800 500 200 R 40 40 1 1 I X +VCC 7 300 -100 200 L 40 40 1 1 W X -INA 2 -800 600 200 R 40 40 1 1 I X -INB 15 -800 400 200 R 40 40 1 1 I X -VCC 10 300 -200 200 L 40 40 1 1 W X CCAP 5 300 400 200 L 40 40 1 1 P X CHA 13 -800 200 200 R 40 40 1 1 I X CHA\ 12 -800 100 200 R 40 40 1 1 I X COM 11 300 -400 200 L 40 40 1 1 W X DNC 14 300 200 200 L 40 40 1 1 P X NC 3 -800 -100 200 R 40 40 1 1 U X NC@1 4 -800 -200 200 R 40 40 1 1 U X NC@2 6 -800 -300 200 R 40 40 1 1 U X NC@3 9 -800 -400 200 R 40 40 1 1 U X OUT 8 300 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA678U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF OPA678U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: OPA678 F0 "IC" -600 825 50 H V L B F1 "OPA678U" -600 -600 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -600 -500 100 -500 P 2 1 0 0 100 -500 100 800 P 2 1 0 0 100 800 -600 800 P 2 1 0 0 -600 800 -600 -500 X +INA 1 -800 700 200 R 40 40 1 1 I X +INB 16 -800 500 200 R 40 40 1 1 I X +VCC 7 300 -100 200 L 40 40 1 1 W X -INA 2 -800 600 200 R 40 40 1 1 I X -INB 15 -800 400 200 R 40 40 1 1 I X -VCC 10 300 -200 200 L 40 40 1 1 W X CCAP 5 300 400 200 L 40 40 1 1 P X CHA 13 -800 200 200 R 40 40 1 1 I X CHA\ 12 -800 100 200 R 40 40 1 1 I X COM 11 300 -400 200 L 40 40 1 1 W X DNC 14 300 200 200 L 40 40 1 1 P X NC 3 -800 -100 200 R 40 40 1 1 U X NC@1 4 -800 -200 200 R 40 40 1 1 U X NC@2 6 -800 -300 200 R 40 40 1 1 U X NC@3 9 -800 -400 200 R 40 40 1 1 U X OUT 8 300 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: OPA2130P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2130P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2130P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2130U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2130U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2130U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2131P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2131P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2131P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2131U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2131U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2131U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2132P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2132P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2132P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2132U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2132U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2132U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2134P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2134P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2134P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2134U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2134U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2134U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2234P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2234P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2234P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2234U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2234U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2234U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2237E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2237E IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2237E" 100 -200 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2237U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2237U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2237U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2336E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2336E IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2336E" 100 -200 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2336P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2336P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2336P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2336U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2336U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2336U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2340E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2340E IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2340E" 100 -200 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2340P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2340P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2340P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2340U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2340U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2340U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2650E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2650E IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2650E" 100 -200 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2650P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2650P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2650P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2650U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2650U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2650U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2658E # Package Name: MSOP08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2658E IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2658E" 100 -200 50 H V L B F2 "burr-brown-MSOP08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2658P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2658P IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2658P" 100 -200 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA2658U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF OPA2658U IC 0 40 Y Y 2 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA2658U" 100 -200 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 8 -100 300 100 D 40 40 1 1 W X V- 4 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O ENDDRAW ENDDEF # # Dev Name: OPA4130P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4130P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4130P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4130U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4130U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4130U" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4131N # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4131N IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4131N" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4131P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4131P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4131P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4131U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4131U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4131U" 100 -200 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 13 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 3 1 I X -IN 11 -300 -100 100 R 40 40 3 1 I X OUT 10 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 14 -300 100 100 R 40 40 4 1 I X -IN 15 -300 -100 100 R 40 40 4 1 I X OUT 16 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4132P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4132P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4132P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4132U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4132U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4132U" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4234P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4234P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4234P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4234U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4234U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4234U" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4237U # Package Name: SSOP16DB # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4237U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4237U" 100 -200 50 H V L B F2 "burr-brown-SSOP16DB" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 13 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 3 1 I X -IN 11 -300 -100 100 R 40 40 3 1 I X OUT 10 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 14 -300 100 100 R 40 40 4 1 I X -IN 15 -300 -100 100 R 40 40 4 1 I X OUT 16 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4336E # Package Name: SSOP16DB # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4336E IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4336E" 100 -200 50 H V L B F2 "burr-brown-SSOP16DB" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 13 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 3 1 I X -IN 11 -300 -100 100 R 40 40 3 1 I X OUT 10 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 14 -300 100 100 R 40 40 4 1 I X -IN 15 -300 -100 100 R 40 40 4 1 I X OUT 16 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4336P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4336P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4336P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4336U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4336U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4336U" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4340E # Package Name: SSOP16DB # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4340E IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4340E" 100 -200 50 H V L B F2 "burr-brown-SSOP16DB" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 13 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 3 1 I X -IN 11 -300 -100 100 R 40 40 3 1 I X OUT 10 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 14 -300 100 100 R 40 40 4 1 I X -IN 15 -300 -100 100 R 40 40 4 1 I X OUT 16 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4340P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4340P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4340P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4340U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4340U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4340U" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4650P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4650P IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4650P" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4650U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4650U IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4650U" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4658UP # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4658UP IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4658UP" 100 -200 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: OPA4658UU # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 4 # DEF OPA4658UU IC 0 40 Y Y 4 L N # Gate Name: A # Symbol Name: OP-AMP+- F0 "IC" 100 225 50 H V L B F1 "OPA4658UU" 100 -200 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -150 125 -150 75 P 2 1 0 0 -175 100 -125 100 P 2 1 0 0 -175 -100 -125 -100 P 2 1 0 0 -100 200 -100 153 P 2 1 0 0 -100 -154 -100 -200 P 2 1 0 0 200 0 -200 200 P 2 1 0 0 -200 200 -200 -200 P 2 1 0 0 -200 -200 200 0 T 1 -66 207 32 0 1 0 V+ T 1 -66 -193 32 0 1 0 V- X +IN 3 -300 100 100 R 40 40 1 1 I X -IN 2 -300 -100 100 R 40 40 1 1 I X OUT 1 300 0 100 L 40 40 1 1 O X V+ 4 -100 300 100 D 40 40 1 1 W X V- 11 -100 -300 100 U 40 40 1 1 W # Gate Name: B # Symbol Name: OP-AMP P 2 2 0 0 -150 125 -150 75 P 2 2 0 0 -175 100 -125 100 P 2 2 0 0 -175 -100 -125 -100 P 2 2 0 0 200 0 -200 200 P 2 2 0 0 -200 200 -200 -200 P 2 2 0 0 -200 -200 200 0 X +IN 5 -300 100 100 R 40 40 2 1 I X -IN 6 -300 -100 100 R 40 40 2 1 I X OUT 7 300 0 100 L 40 40 2 1 O # Gate Name: C # Symbol Name: OP-AMP P 2 3 0 0 -150 125 -150 75 P 2 3 0 0 -175 100 -125 100 P 2 3 0 0 -175 -100 -125 -100 P 2 3 0 0 200 0 -200 200 P 2 3 0 0 -200 200 -200 -200 P 2 3 0 0 -200 -200 200 0 X +IN 10 -300 100 100 R 40 40 3 1 I X -IN 9 -300 -100 100 R 40 40 3 1 I X OUT 8 300 0 100 L 40 40 3 1 O # Gate Name: D # Symbol Name: OP-AMP P 2 4 0 0 -150 125 -150 75 P 2 4 0 0 -175 100 -125 100 P 2 4 0 0 -175 -100 -125 -100 P 2 4 0 0 200 0 -200 200 P 2 4 0 0 -200 200 -200 -200 P 2 4 0 0 -200 -200 200 0 X +IN 12 -300 100 100 R 40 40 4 1 I X -IN 13 -300 -100 100 R 40 40 4 1 I X OUT 14 300 0 100 L 40 40 4 1 O ENDDRAW ENDDEF # # Dev Name: PCM63P # Package Name: DIL28 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM63P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM63P F0 "IC" -500 725 50 H V L B F1 "PCM63P" -500 -1300 50 H V L B F2 "burr-brown-DIL28" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -1200 200 -1200 P 2 1 0 0 200 -1200 200 700 P 2 1 0 0 200 700 -500 700 P 2 1 0 0 -500 700 -500 -1200 X +VA 2 400 -500 200 L 40 40 1 1 W X +VD 13 400 -700 200 L 40 40 1 1 W X -VA 28 400 -600 200 L 40 40 1 1 W X -VD 11 400 -800 200 L 40 40 1 1 W X ACOM 7 400 -1000 200 L 40 40 1 1 W X BPO 5 400 400 200 L 40 40 1 1 O X CLK 18 -700 400 200 R 40 40 1 1 I X DATA 21 -700 600 200 R 40 40 1 1 I X DCOM 12 400 -1100 200 L 40 40 1 1 W X IOUT 6 400 600 200 L 40 40 1 1 O X LB2 24 -700 -500 200 R 40 40 1 1 P X LE 20 -700 300 200 R 40 40 1 1 I X NC 8 -700 -800 200 R 40 40 1 1 U X NC@1 14 -700 -900 200 R 40 40 1 1 U X NC@2 15 -700 -1000 200 R 40 40 1 1 U X NC@3 16 -700 -1100 200 R 40 40 1 1 U X NC@4 17 400 200 200 L 40 40 1 1 U X NC@5 19 400 100 200 L 40 40 1 1 U X NC@6 22 400 0 200 L 40 40 1 1 U X NC@7 26 400 -100 200 L 40 40 1 1 U X NC@8 27 400 -200 200 L 40 40 1 1 U X OCAP 4 -700 -100 200 R 40 40 1 1 P X POT 25 -700 -600 200 R 40 40 1 1 P X RCAP 3 -700 0 200 R 40 40 1 1 P X RF1 9 -700 -200 200 R 40 40 1 1 P X RF2 10 -700 -300 200 R 40 40 1 1 P X SCAP 1 -700 100 200 R 40 40 1 1 P X UB2 23 -700 -400 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: PCM1702P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1702P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1702 F0 "IC" -300 625 50 H V L B F1 "PCM1702P" -300 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 400 -600 P 2 1 0 0 400 -600 400 600 P 2 1 0 0 400 600 -300 600 P 2 1 0 0 -300 600 -300 -600 X +VCC 9 600 200 200 L 40 40 1 1 W X +VDD 3 600 0 200 L 40 40 1 1 W X -VCC 16 600 100 200 L 40 40 1 1 W X -VDD 5 600 -100 200 L 40 40 1 1 W X ACOM 12 600 -300 200 L 40 40 1 1 W X ACOM@1 13 600 -400 200 L 40 40 1 1 W X BPO 10 -500 0 200 R 40 40 1 1 P X CLOCK 2 -500 300 200 R 40 40 1 1 I X DATA 1 -500 500 200 R 40 40 1 1 I X DCOM 4 600 -500 200 L 40 40 1 1 W X IOUT 11 600 500 200 L 40 40 1 1 O X LE 6 -500 200 200 R 40 40 1 1 I X NC 7 -500 -400 200 R 40 40 1 1 U X NC@1 8 -500 -500 200 R 40 40 1 1 U X REF 15 -500 -200 200 R 40 40 1 1 P X SERV 14 -500 -100 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: PCM1702U # Package Name: SO20L # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1702U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1702U F0 "IC" -300 825 50 H V L B F1 "PCM1702U" -300 -900 50 H V L B F2 "burr-brown-SO20L" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -800 400 -800 P 2 1 0 0 400 -800 400 800 P 2 1 0 0 400 800 -300 800 P 2 1 0 0 -300 800 -300 -800 X +VCC 11 600 0 200 L 40 40 1 1 W X +VDD 4 600 -200 200 L 40 40 1 1 W X -VCC 20 600 -100 200 L 40 40 1 1 W X -VDD 6 600 -300 200 L 40 40 1 1 W X ACOM 15 600 -500 200 L 40 40 1 1 W X ACOM@1 16 600 -600 200 L 40 40 1 1 W X BPO 12 -500 200 200 R 40 40 1 1 P X CLOCK 2 -500 500 200 R 40 40 1 1 I X DATA 1 -500 700 200 R 40 40 1 1 I X DCOM 5 600 -700 200 L 40 40 1 1 W X IOUT 14 600 700 200 L 40 40 1 1 O X LE 7 -500 400 200 R 40 40 1 1 I X NC 3 -500 -200 200 R 40 40 1 1 U X NC@1 8 -500 -300 200 R 40 40 1 1 U X NC@2 9 -500 -400 200 R 40 40 1 1 U X NC@3 10 -500 -500 200 R 40 40 1 1 U X NC@4 13 -500 -600 200 R 40 40 1 1 U X NC@5 18 -500 -700 200 R 40 40 1 1 U X REF 19 -500 0 200 R 40 40 1 1 P X SERV 17 -500 100 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: PCM1710U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1710U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1710 F0 "IC" -400 1125 50 H V L B F1 "PCM1710U" -400 -1300 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1200 -400 -1200 P 2 1 0 0 -400 -1200 -400 1100 P 2 1 0 0 -400 1100 400 1100 P 2 1 0 0 400 1100 400 -1200 X AGND1 14 600 -700 200 L 40 40 1 1 W X AGND2L 19 600 -900 200 L 40 40 1 1 W X AGND2R 10 600 -800 200 L 40 40 1 1 W X BCKIN 3 -600 500 200 R 40 40 1 1 I X CKSL 23 -600 100 200 R 40 40 1 1 I X CLKO 4 600 600 200 L 40 40 1 1 O X DGND 7 600 -1000 200 L 40 40 1 1 W X DGND@1 22 600 -1100 200 L 40 40 1 1 W X DIN 2 -600 1000 200 R 40 40 1 1 I X EXT1L 18 600 300 200 L 40 40 1 1 O X EXT1R 11 600 400 200 L 40 40 1 1 O X EXT2L 17 600 100 200 L 40 40 1 1 O X EXT2R 12 600 200 200 L 40 40 1 1 O X LRCIN 1 -600 600 200 R 40 40 1 1 I X MC/DM1 26 -600 400 200 R 40 40 1 1 I X MC/DM2 27 -600 300 200 R 40 40 1 1 I X ML/DSD 28 -600 200 200 R 40 40 1 1 I X MODE 24 -600 -100 200 R 40 40 1 1 I X MUTE 25 -600 0 200 R 40 40 1 1 I X OUTL 16 600 900 200 L 40 40 1 1 O X OUTR 13 600 1000 200 L 40 40 1 1 O X VCC1 15 600 -100 200 L 40 40 1 1 W X VCC2L 20 600 -300 200 L 40 40 1 1 W X VCC2R 9 600 -200 200 L 40 40 1 1 W X VDD 8 600 -400 200 L 40 40 1 1 W X VDD@1 21 600 -500 200 L 40 40 1 1 W X XTI 5 -600 700 200 R 40 40 1 1 I X XTO 6 600 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1712U # Package Name: SO28-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1712U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1712 F0 "IC" -400 1125 50 H V L B F1 "PCM1712U" -400 -1300 50 H V L B F2 "burr-brown-SO28-3" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1200 -400 -1200 P 2 1 0 0 -400 -1200 -400 1100 P 2 1 0 0 -400 1100 400 1100 P 2 1 0 0 400 1100 400 -1200 X AGND1 14 600 -700 200 L 40 40 1 1 W X AGND2L 19 600 -900 200 L 40 40 1 1 W X AGND2R 10 600 -800 200 L 40 40 1 1 W X BCKIN 3 -600 500 200 R 40 40 1 1 I X CLKO 4 600 600 200 L 40 40 1 1 O X DGND 7 600 -1000 200 L 40 40 1 1 W X DGND@1 22 600 -1100 200 L 40 40 1 1 W X DIN 2 -600 1000 200 R 40 40 1 1 I X EXT1L 18 600 300 200 L 40 40 1 1 O X EXT1R 11 600 400 200 L 40 40 1 1 O X EXT2L 17 600 100 200 L 40 40 1 1 O X EXT2R 12 600 200 200 L 40 40 1 1 O X LRCIN 1 -600 600 200 R 40 40 1 1 I X MC/DM1 26 -600 400 200 R 40 40 1 1 I X MC/DM2 27 -600 300 200 R 40 40 1 1 I X ML/DSD 28 -600 200 200 R 40 40 1 1 I X MODE 24 -600 0 200 R 40 40 1 1 I X MUTE 25 -600 100 200 R 40 40 1 1 I X NC 23 -600 -200 200 R 40 40 1 1 U X OUTL 16 600 900 200 L 40 40 1 1 O X OUTR 13 600 1000 200 L 40 40 1 1 O X VCC1 15 600 -100 200 L 40 40 1 1 W X VCC2L 20 600 -300 200 L 40 40 1 1 W X VCC2R 9 600 -200 200 L 40 40 1 1 W X VDD 8 600 -400 200 L 40 40 1 1 W X VDD@1 21 600 -500 200 L 40 40 1 1 W X XTI 5 -600 700 200 R 40 40 1 1 I X XTO 6 600 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1715U # Package Name: SOJ28-4 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1715U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1715 F0 "IC" -400 1125 50 H V L B F1 "PCM1715U" -400 -1300 50 H V L B F2 "burr-brown-SOJ28-4" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1200 -400 -1200 P 2 1 0 0 -400 -1200 -400 1100 P 2 1 0 0 -400 1100 400 1100 P 2 1 0 0 400 1100 400 -1200 X AGND1 14 600 -700 200 L 40 40 1 1 W X AGND2L 19 600 -900 200 L 40 40 1 1 W X AGND2R 10 600 -800 200 L 40 40 1 1 W X BCKIN 3 -600 500 200 R 40 40 1 1 I X CKSL 23 -600 100 200 R 40 40 1 1 I X CLKO 4 600 600 200 L 40 40 1 1 O X DGND 7 600 -1000 200 L 40 40 1 1 W X DGND@1 22 600 -1100 200 L 40 40 1 1 W X DIN 2 -600 1000 200 R 40 40 1 1 I X EXT1L 18 600 300 200 L 40 40 1 1 O X EXT1R 11 600 400 200 L 40 40 1 1 O X EXT2L 17 600 100 200 L 40 40 1 1 O X EXT2R 12 600 200 200 L 40 40 1 1 O X LRCIN 1 -600 600 200 R 40 40 1 1 I X MC 27 -600 300 200 R 40 40 1 1 I X MD 26 -600 400 200 R 40 40 1 1 I X ML 28 -600 200 200 R 40 40 1 1 I X NC 24 -600 -200 200 R 40 40 1 1 U X OUTL 16 600 900 200 L 40 40 1 1 O X OUTR 13 600 1000 200 L 40 40 1 1 O X RSTB 25 -600 0 200 R 40 40 1 1 I X VCC1 15 600 -100 200 L 40 40 1 1 W X VCC2L 20 600 -300 200 L 40 40 1 1 W X VCC2R 9 600 -200 200 L 40 40 1 1 W X VDD 8 600 -400 200 L 40 40 1 1 W X VDD@1 21 600 -500 200 L 40 40 1 1 W X XTI 5 -600 700 200 R 40 40 1 1 I X XTO 6 600 700 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1717E # Package Name: SSOP20BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1717E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1717 F0 "IC" -400 725 50 H V L B F1 "PCM1717E" -400 -900 50 H V L B F2 "burr-brown-SSOP20BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 400 -800 P 2 1 0 0 400 -800 400 700 P 2 1 0 0 400 700 -400 700 P 2 1 0 0 -400 700 -400 -800 X AGND 10 600 -600 200 L 40 40 1 1 W X BCKIN 6 -600 -100 200 R 40 40 1 1 I X CLKO 19 600 100 200 L 40 40 1 1 O X D/C_L 13 600 300 200 L 40 40 1 1 O X D/C_R 8 600 400 200 L 40 40 1 1 O X DGND 2 600 -700 200 L 40 40 1 1 W X DIN 5 -600 600 200 R 40 40 1 1 I X LRCIN 4 -600 -200 200 R 40 40 1 1 I X MC/DM1 17 -600 -500 200 R 40 40 1 1 I X MD/DM0 16 -600 -400 200 R 40 40 1 1 I X ML/MUTE 18 -600 -300 200 R 40 40 1 1 I X MODE 14 -600 -600 200 R 40 40 1 1 I X OUTL 12 600 500 200 L 40 40 1 1 O X OUTR 9 600 600 200 L 40 40 1 1 O X RSTB 15 -600 -700 200 R 40 40 1 1 I X VCC 11 600 -300 200 L 40 40 1 1 W X VDD 3 600 -400 200 L 40 40 1 1 W X XTI 1 -600 0 200 R 40 40 1 1 I X XTO 20 600 0 200 L 40 40 1 1 O X ZERO 7 600 -100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1718E # Package Name: SSOP20DB # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1718E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1718 F0 "IC" -400 725 50 H V L B F1 "PCM1718E" -400 -800 50 H V L B F2 "burr-brown-SSOP20DB" 0 150 50 H I C C DRAW P 2 1 0 0 300 -700 -400 -700 P 2 1 0 0 -400 -700 -400 700 P 2 1 0 0 -400 700 300 700 P 2 1 0 0 300 700 300 -700 X AGND 10 500 -300 200 L 40 40 1 1 W X BCKIN 6 -600 100 200 R 40 40 1 1 I X CLKO 19 500 100 200 L 40 40 1 1 O X D/C_L 13 500 -600 200 L 40 40 1 1 W X D/C_R 8 500 -500 200 L 40 40 1 1 W X DGND 2 500 -400 200 L 40 40 1 1 W X DIN 5 -600 600 200 R 40 40 1 1 I X DM0 16 -600 -100 200 R 40 40 1 1 I X DM1 17 -600 -200 200 R 40 40 1 1 I X FOR 14 -600 0 200 R 40 40 1 1 I X LRCIN 4 -600 200 200 R 40 40 1 1 I X MUTE 18 -600 -300 200 R 40 40 1 1 I X OUTL 12 500 500 200 L 40 40 1 1 O X OUTR 9 500 600 200 L 40 40 1 1 O X RSTB 15 -600 -400 200 R 40 40 1 1 I X VCC 11 500 -100 200 L 40 40 1 1 W X VDD 3 500 -200 200 L 40 40 1 1 W X XTI 1 -600 300 200 R 40 40 1 1 I X XTO 20 500 300 200 L 40 40 1 1 O X ZERO 7 500 200 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1719E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1719E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1719 F0 "IC" -500 925 50 H V L B F1 "PCM1719E" -500 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 -500 -1100 200 -1100 P 2 1 0 0 200 -1100 200 900 P 2 1 0 0 200 900 -500 900 P 2 1 0 0 -500 900 -500 -1100 X AGND 10 400 -600 200 L 40 40 1 1 W X BCKIN 6 -700 0 200 R 40 40 1 1 I X CLKO 27 400 0 200 L 40 40 1 1 O X COM 21 400 -900 200 L 40 40 1 1 W X DGND 2 400 -700 200 L 40 40 1 1 W X DIN 5 -700 800 200 R 40 40 1 1 I X LRCIN 4 -700 100 200 R 40 40 1 1 I X MC 25 -700 -400 200 R 40 40 1 1 I X MD 24 -700 -300 200 R 40 40 1 1 I X ML 26 -700 -500 200 R 40 40 1 1 I X NC 8 -700 -900 200 R 40 40 1 1 U X NC@1 22 -700 -1000 200 R 40 40 1 1 U X OUTL 20 400 700 200 L 40 40 1 1 O X OUTR 9 400 800 200 L 40 40 1 1 O X PAGND 14 400 -800 200 L 40 40 1 1 W X PCOM 12 400 -1000 200 L 40 40 1 1 W X PINL 18 -700 400 200 R 40 40 1 1 I X PINR 11 -700 500 200 R 40 40 1 1 I X PMUTE 17 -700 -100 200 R 40 40 1 1 I X POUTL 16 400 400 200 L 40 40 1 1 O X POUTR 13 400 500 200 L 40 40 1 1 O X PVCC 15 400 -300 200 L 40 40 1 1 W X RSTB 23 -700 -200 200 R 40 40 1 1 I X VCC 19 400 -200 200 L 40 40 1 1 W X VDD 3 400 -400 200 L 40 40 1 1 W X XTI 1 -700 200 200 R 40 40 1 1 I X XTO 28 400 200 200 L 40 40 1 1 O X ZERO 7 400 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1720E # Package Name: SSOP20BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1720E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1720 F0 "IC" -400 825 50 H V L B F1 "PCM1720E" -400 -900 50 H V L B F2 "burr-brown-SSOP20BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 300 -800 P 2 1 0 0 300 -800 300 800 P 2 1 0 0 300 800 -400 800 P 2 1 0 0 -400 800 -400 -800 X AGND 10 500 -600 200 L 40 40 1 1 W X BCKIN 14 -600 0 200 R 40 40 1 1 I X CAP 13 -600 -300 200 R 40 40 1 1 P X DGND 20 500 -700 200 L 40 40 1 1 W X DIN 15 -600 700 200 R 40 40 1 1 I X LRCIN 16 -600 -100 200 R 40 40 1 1 I X MC 5 -600 300 200 R 40 40 1 1 I X MD 6 -600 200 200 R 40 40 1 1 I X ML 4 -600 400 200 R 40 40 1 1 I X NC 1 -600 -500 200 R 40 40 1 1 U X NC@1 17 -600 -600 200 R 40 40 1 1 U X NC@2 18 -600 -700 200 R 40 40 1 1 U X OUTL 12 500 600 200 L 40 40 1 1 O X OUTR 9 500 700 200 L 40 40 1 1 O X RSTB 7 -600 100 200 R 40 40 1 1 I X SCKI 2 -600 500 200 R 40 40 1 1 I X TEST 3 500 300 200 L 40 40 1 1 O X VCC 11 500 -300 200 L 40 40 1 1 W X VDD 19 500 -400 200 L 40 40 1 1 W X ZERO 8 500 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1721E # Package Name: SSOP24BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1721E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1721 F0 "IC" -400 925 50 H V L B F1 "PCM1721E" -400 -1000 50 H V L B F2 "burr-brown-SSOP24BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -900 300 -900 P 2 1 0 0 300 -900 300 900 P 2 1 0 0 300 900 -400 900 P 2 1 0 0 -400 900 -400 -900 X AGND 12 500 -600 200 L 40 40 1 1 W X BCKIN 16 -600 0 200 R 40 40 1 1 I X CAP 15 -600 -300 200 R 40 40 1 1 P X DGND 22 500 -700 200 L 40 40 1 1 W X DIN 17 -600 800 200 R 40 40 1 1 I X LRCIN 18 -600 -100 200 R 40 40 1 1 I X MC 7 -600 300 200 R 40 40 1 1 I X MCKI 1 -600 600 200 R 40 40 1 1 I X MD 8 -600 200 200 R 40 40 1 1 I X ML 6 -600 400 200 R 40 40 1 1 I X NC 24 -600 -800 200 R 40 40 1 1 U X OUTL 14 500 700 200 L 40 40 1 1 O X OUTR 11 500 800 200 L 40 40 1 1 O X PGND 23 500 -800 200 L 40 40 1 1 W X RES 5 -600 -500 200 R 40 40 1 1 P X RES@1 20 -600 -600 200 R 40 40 1 1 P X RSTB 9 -600 100 200 R 40 40 1 1 I X SCKI 4 -600 500 200 R 40 40 1 1 I X SCKO 2 500 500 200 L 40 40 1 1 O X TEST 19 -600 -700 200 R 40 40 1 1 P X VCC 13 500 -300 200 L 40 40 1 1 W X VCP 3 500 -500 200 L 40 40 1 1 W X VDD 21 500 -400 200 L 40 40 1 1 W X ZERO 10 500 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1723E # Package Name: SSOP24BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1723E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1723 F0 "IC" -400 825 50 H V L B F1 "PCM1723E" -400 -1000 50 H V L B F2 "burr-brown-SSOP24BU" 0 150 50 H I C C DRAW P 2 1 0 0 400 -900 -400 -900 P 2 1 0 0 -400 -900 -400 800 P 2 1 0 0 -400 800 400 800 P 2 1 0 0 400 800 400 -900 X AGND 12 600 -600 200 L 40 40 1 1 W X BCKIN 16 -600 -100 200 R 40 40 1 1 I X CAP 15 -600 -400 200 R 40 40 1 1 P X DGND 22 600 -700 200 L 40 40 1 1 W X DIN 17 -600 700 200 R 40 40 1 1 I X LRCIN 18 -600 -200 200 R 40 40 1 1 I X MC 7 -600 200 200 R 40 40 1 1 I X MCKO 5 600 300 200 L 40 40 1 1 O X MD 8 -600 100 200 R 40 40 1 1 I X ML 6 -600 300 200 R 40 40 1 1 I X NC 4 -600 -600 200 R 40 40 1 1 U X NC@1 19 -600 -700 200 R 40 40 1 1 U X OUTL 14 600 600 200 L 40 40 1 1 O X OUTR 11 600 700 200 L 40 40 1 1 O X PGND 23 600 -800 200 L 40 40 1 1 W X RES 20 -600 -800 200 R 40 40 1 1 P X RSTB 9 -600 0 200 R 40 40 1 1 I X SCKO 2 600 200 200 L 40 40 1 1 O X VCC 13 600 -200 200 L 40 40 1 1 W X VCP 3 600 -400 200 L 40 40 1 1 W X VDD 21 600 -300 200 L 40 40 1 1 W X XTI 1 -600 400 200 R 40 40 1 1 I X XTO 24 600 400 200 L 40 40 1 1 O X ZERO 10 600 100 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1725U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF PCM1725U IC 0 40 Y Y 2 L N # Gate Name: G$1 # Symbol Name: PCM1725 F0 "IC" -300 525 50 H V L B F1 "PCM1725U" -300 -600 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -500 400 -500 P 2 1 0 0 400 -500 400 500 P 2 1 0 0 400 500 -300 500 P 2 1 0 0 -300 500 -300 -500 X BCKIN 3 -500 100 200 R 40 40 1 1 I X CAP 5 -500 -400 200 R 40 40 1 1 P X DIN 2 -500 400 200 R 40 40 1 1 I X DM 12 -500 0 200 R 40 40 1 1 I X FOR 13 -500 -200 200 R 40 40 1 1 I X LRCIN 1 -500 200 200 R 40 40 1 1 I X NC 4 600 -200 200 L 40 40 1 1 U X NC@1 10 600 -300 200 L 40 40 1 1 U X NC@2 11 600 -400 200 L 40 40 1 1 U X OUTL 9 600 300 200 L 40 40 1 1 O X OUTR 6 600 400 200 L 40 40 1 1 O X SCKI 14 -500 -100 200 R 40 40 1 1 I # Gate Name: P # Symbol Name: PWRN T 1 50 -155 50 0 2 0 GND T 1 50 175 50 0 2 0 VCC X GND 7 0 -300 200 U 40 40 2 1 W X VCC 8 0 300 200 D 40 40 2 1 W ENDDRAW ENDDEF # # Dev Name: PCM1726E # Package Name: SSOP20BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1726E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1726 F0 "IC" -300 725 50 H V L B F1 "PCM1726E" -300 -1000 50 H V L B F2 "burr-brown-SSOP20BU" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -900 400 -900 P 2 1 0 0 400 -900 400 700 P 2 1 0 0 400 700 -300 700 P 2 1 0 0 -300 700 -300 -900 X AGND 10 600 -700 200 L 40 40 1 1 W X BCKIN 14 -500 -100 200 R 40 40 1 1 I X CAP 13 -500 -400 200 R 40 40 1 1 P X DGND 20 600 -800 200 L 40 40 1 1 W X DIN 15 -500 600 200 R 40 40 1 1 I X FOR 4 -500 300 200 R 40 40 1 1 I X LRCIN 16 -500 -200 200 R 40 40 1 1 I X LRPL 5 -500 200 200 R 40 40 1 1 I X MUTE 6 -500 100 200 R 40 40 1 1 I X NC 1 -500 -800 200 R 40 40 1 1 U X OUTL 12 600 500 200 L 40 40 1 1 O X OUTR 9 600 600 200 L 40 40 1 1 O X RES 3 -500 -500 200 R 40 40 1 1 P X RES@1 18 -500 -600 200 R 40 40 1 1 P X RSTB 7 -500 0 200 R 40 40 1 1 I X SCKI 2 -500 400 200 R 40 40 1 1 I X TEST 17 -500 -700 200 R 40 40 1 1 P X VCC 11 600 -400 200 L 40 40 1 1 W X VDD 19 600 -500 200 L 40 40 1 1 W X ZERO 8 600 300 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1727E # Package Name: SSOP24BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1727E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1727 F0 "IC" -400 925 50 H V L B F1 "PCM1727E" -400 -1000 50 H V L B F2 "burr-brown-SSOP24BU" 0 150 50 H I C C DRAW P 2 1 0 0 400 -900 -400 -900 P 2 1 0 0 -400 -900 -400 900 P 2 1 0 0 -400 900 400 900 P 2 1 0 0 400 900 400 -900 X AGND 12 600 -700 200 L 40 40 1 1 W X BCKIN 17 -600 -100 200 R 40 40 1 1 I X CAP 15 -600 -400 200 R 40 40 1 1 P X DGND 23 600 -600 200 L 40 40 1 1 W X DIN 18 -600 800 200 R 40 40 1 1 I X LRCIN 19 -600 -200 200 R 40 40 1 1 I X MC 8 -600 200 200 R 40 40 1 1 I X MCKO 4 600 400 200 L 40 40 1 1 O X MD 9 -600 100 200 R 40 40 1 1 I X ML 7 -600 300 200 R 40 40 1 1 I X OUTL 14 600 700 200 L 40 40 1 1 O X OUTR 11 600 800 200 L 40 40 1 1 O X PGND 2 600 -800 200 L 40 40 1 1 W X RSTB\ 10 -600 0 200 R 40 40 1 1 I X RSV 5 -600 -600 200 R 40 40 1 1 P X SCKO1 21 600 300 200 L 40 40 1 1 O X SCKO2 20 600 200 200 L 40 40 1 1 O X SCKO3 6 600 100 200 L 40 40 1 1 O X VCA 13 600 -300 200 L 40 40 1 1 W X VCP 3 600 -400 200 L 40 40 1 1 W X VDD 22 600 -200 200 L 40 40 1 1 W X XTI 1 -600 500 200 R 40 40 1 1 I X XTO 24 600 500 200 L 40 40 1 1 O X ZERO\ 16 600 0 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM1800E # Package Name: SSOP24BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM1800E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM1800 F0 "IC" -400 825 50 H V L B F1 "PCM1800E" -400 -900 50 H V L B F2 "burr-brown-SSOP24BU" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -800 400 -800 P 2 1 0 0 400 -800 400 800 P 2 1 0 0 400 800 -400 800 P 2 1 0 0 -400 800 -400 -800 X AGND 24 600 -600 200 L 40 40 1 1 W X BCK 14 -600 -600 200 R 40 40 1 1 B X BYPAS 7 -600 300 200 R 40 40 1 1 I X CNL 21 600 0 200 L 40 40 1 1 P X CNR 19 600 200 200 L 40 40 1 1 P X CPL 22 600 -100 200 L 40 40 1 1 P X CPR 20 600 100 200 L 40 40 1 1 P X DGND 17 600 -700 200 L 40 40 1 1 W X FMT0 8 -600 200 200 R 40 40 1 1 I X FMT1 9 -600 100 200 R 40 40 1 1 I X FSYNC 12 -600 -400 200 R 40 40 1 1 B X INL 1 -600 600 200 R 40 40 1 1 I X INR 5 -600 700 200 R 40 40 1 1 I X LRCK 13 -600 -500 200 R 40 40 1 1 B X MODE0 10 -600 0 200 R 40 40 1 1 I X MODE1 11 -600 -100 200 R 40 40 1 1 I X OUT 15 600 700 200 L 40 40 1 1 O X REF1 2 600 500 200 L 40 40 1 1 P X REF2 4 600 300 200 L 40 40 1 1 P X REFCOM 3 600 400 200 L 40 40 1 1 P X RSTB 6 -600 400 200 R 40 40 1 1 I X SYSCLK 16 -600 -200 200 R 40 40 1 1 I X VCC 23 600 -300 200 L 40 40 1 1 W X VDD 18 600 -400 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: PCM3000E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM3000E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM3000 F0 "IC" -300 1125 50 H V L B F1 "PCM3000E" -300 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 400 -1100 -300 -1100 P 2 1 0 0 -300 -1100 -300 1100 P 2 1 0 0 -300 1100 400 1100 P 2 1 0 0 400 1100 400 -1100 X AGND1 3 600 -800 200 L 40 40 1 1 W X AGND2 13 600 -900 200 L 40 40 1 1 W X BCKIN 17 -500 100 200 R 40 40 1 1 I X CLKIO 22 -500 -200 200 R 40 40 1 1 B X CNL 9 600 0 200 L 40 40 1 1 P X CNR 8 600 100 200 L 40 40 1 1 P X CPL 10 600 -100 200 L 40 40 1 1 P X CPR 7 600 200 200 L 40 40 1 1 P X DGND 24 600 -1000 200 L 40 40 1 1 W X DIN 18 -500 1000 200 R 40 40 1 1 I X DOUT 19 600 1000 200 L 40 40 1 1 O X INL 1 -500 800 200 R 40 40 1 1 I X INR 6 -500 900 200 R 40 40 1 1 I X LRCIN 16 -500 200 200 R 40 40 1 1 I X MC 25 -500 300 200 R 40 40 1 1 I X MD 26 -500 400 200 R 40 40 1 1 I X ML 27 -500 500 200 R 40 40 1 1 I X OUTL 15 600 800 200 L 40 40 1 1 O X OUTR 12 600 900 200 L 40 40 1 1 O X REFL 4 600 400 200 L 40 40 1 1 P X REFR 5 600 300 200 L 40 40 1 1 P X RSTB 28 -500 0 200 R 40 40 1 1 I X VCC1 2 600 -400 200 L 40 40 1 1 W X VCC2 14 600 -500 200 L 40 40 1 1 W X VCOM 11 600 -200 200 L 40 40 1 1 P X VDD 23 600 -600 200 L 40 40 1 1 W X XTIN 20 -500 600 200 R 40 40 1 1 I X XTO 21 600 600 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PCM3001E # Package Name: SSOP28BU # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PCM3001E IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PCM3001 F0 "IC" -400 1125 50 H V L B F1 "PCM3001E" -400 -1200 50 H V L B F2 "burr-brown-SSOP28BU" 0 150 50 H I C C DRAW P 2 1 0 0 300 -1100 -400 -1100 P 2 1 0 0 -400 -1100 -400 1100 P 2 1 0 0 -400 1100 300 1100 P 2 1 0 0 300 1100 300 -1100 X AGND1 3 500 -800 200 L 40 40 1 1 W X AGND2 13 500 -900 200 L 40 40 1 1 W X BCKIN 17 -600 100 200 R 40 40 1 1 I X CLKIO 22 -600 -200 200 R 40 40 1 1 B X CNL 9 500 0 200 L 40 40 1 1 P X CNR 8 500 100 200 L 40 40 1 1 P X CPL 10 500 -100 200 L 40 40 1 1 P X CPR 7 500 200 200 L 40 40 1 1 P X DGND 24 500 -1000 200 L 40 40 1 1 W X DIN 18 -600 1000 200 R 40 40 1 1 I X DOUT 19 500 1000 200 L 40 40 1 1 O X FMT0 27 -600 500 200 R 40 40 1 1 I X FMT1 26 -600 400 200 R 40 40 1 1 I X FMT2 25 -600 300 200 R 40 40 1 1 I X INL 1 -600 800 200 R 40 40 1 1 I X INR 6 -600 900 200 R 40 40 1 1 I X LRCIN 16 -600 200 200 R 40 40 1 1 I X OUTL 15 500 800 200 L 40 40 1 1 O X OUTR 12 500 900 200 L 40 40 1 1 O X REFL 4 500 400 200 L 40 40 1 1 P X REFR 5 500 300 200 L 40 40 1 1 P X RSTB 28 -600 0 200 R 40 40 1 1 I X VCC1 2 500 -400 200 L 40 40 1 1 W X VCC2 14 500 -500 200 L 40 40 1 1 W X VCOM 11 500 -200 200 L 40 40 1 1 P X VDD 23 500 -600 200 L 40 40 1 1 W X XTIN 20 -600 600 200 R 40 40 1 1 I X XTO 21 500 600 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: PGA206P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PGA206P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PGA206 F0 "IC" -300 725 50 H V L B F1 "PGA206P" -300 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 -600 X +IN 5 -500 600 200 R 40 40 1 1 I X -IN 4 -500 500 200 R 40 40 1 1 I X A0 15 -500 300 200 R 40 40 1 1 I X A1 16 -500 200 200 R 40 40 1 1 I X DGND 14 500 -500 200 L 40 40 1 1 W X NC 2 500 300 200 L 40 40 1 1 U X NC@1 3 500 200 200 L 40 40 1 1 U X OUT 11 500 600 200 L 40 40 1 1 O X REF 10 -500 -500 200 R 40 40 1 1 P X SENSE 12 -500 -400 200 R 40 40 1 1 P X V+ 13 500 -200 200 L 40 40 1 1 W X V- 8 500 -300 200 L 40 40 1 1 W X VO1 1 -500 0 200 R 40 40 1 1 P X VO2 9 -500 -100 200 R 40 40 1 1 P X VOS 6 -500 -200 200 R 40 40 1 1 P X VOS@1 7 -500 -300 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: PGA206U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PGA206U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PGA206 F0 "IC" -300 725 50 H V L B F1 "PGA206U" -300 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 -600 X +IN 5 -500 600 200 R 40 40 1 1 I X -IN 4 -500 500 200 R 40 40 1 1 I X A0 15 -500 300 200 R 40 40 1 1 I X A1 16 -500 200 200 R 40 40 1 1 I X DGND 14 500 -500 200 L 40 40 1 1 W X NC 2 500 300 200 L 40 40 1 1 U X NC@1 3 500 200 200 L 40 40 1 1 U X OUT 11 500 600 200 L 40 40 1 1 O X REF 10 -500 -500 200 R 40 40 1 1 P X SENSE 12 -500 -400 200 R 40 40 1 1 P X V+ 13 500 -200 200 L 40 40 1 1 W X V- 8 500 -300 200 L 40 40 1 1 W X VO1 1 -500 0 200 R 40 40 1 1 P X VO2 9 -500 -100 200 R 40 40 1 1 P X VOS 6 -500 -200 200 R 40 40 1 1 P X VOS@1 7 -500 -300 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: PGA207P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PGA207P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PGA206 F0 "IC" -300 725 50 H V L B F1 "PGA207P" -300 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 -600 X +IN 5 -500 600 200 R 40 40 1 1 I X -IN 4 -500 500 200 R 40 40 1 1 I X A0 15 -500 300 200 R 40 40 1 1 I X A1 16 -500 200 200 R 40 40 1 1 I X DGND 14 500 -500 200 L 40 40 1 1 W X NC 2 500 300 200 L 40 40 1 1 U X NC@1 3 500 200 200 L 40 40 1 1 U X OUT 11 500 600 200 L 40 40 1 1 O X REF 10 -500 -500 200 R 40 40 1 1 P X SENSE 12 -500 -400 200 R 40 40 1 1 P X V+ 13 500 -200 200 L 40 40 1 1 W X V- 8 500 -300 200 L 40 40 1 1 W X VO1 1 -500 0 200 R 40 40 1 1 P X VO2 9 -500 -100 200 R 40 40 1 1 P X VOS 6 -500 -200 200 R 40 40 1 1 P X VOS@1 7 -500 -300 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: PGA207U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF PGA207U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: PGA206 F0 "IC" -300 725 50 H V L B F1 "PGA207U" -300 -700 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -600 300 -600 P 2 1 0 0 300 -600 300 700 P 2 1 0 0 300 700 -300 700 P 2 1 0 0 -300 700 -300 -600 X +IN 5 -500 600 200 R 40 40 1 1 I X -IN 4 -500 500 200 R 40 40 1 1 I X A0 15 -500 300 200 R 40 40 1 1 I X A1 16 -500 200 200 R 40 40 1 1 I X DGND 14 500 -500 200 L 40 40 1 1 W X NC 2 500 300 200 L 40 40 1 1 U X NC@1 3 500 200 200 L 40 40 1 1 U X OUT 11 500 600 200 L 40 40 1 1 O X REF 10 -500 -500 200 R 40 40 1 1 P X SENSE 12 -500 -400 200 R 40 40 1 1 P X V+ 13 500 -200 200 L 40 40 1 1 W X V- 8 500 -300 200 L 40 40 1 1 W X VO1 1 -500 0 200 R 40 40 1 1 P X VO2 9 -500 -100 200 R 40 40 1 1 P X VOS 6 -500 -200 200 R 40 40 1 1 P X VOS@1 7 -500 -300 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: REF102M # Package Name: TO99 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REF102M IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REF102 F0 "IC" -300 425 50 H V L B F1 "REF102M" -300 -400 50 H V L B F2 "burr-brown-TO99" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 300 -300 P 2 1 0 0 300 -300 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X COM 4 500 -200 200 L 40 40 1 1 W X NC 1 -500 0 200 R 40 40 1 1 U X NC@1 3 -500 -100 200 R 40 40 1 1 U X NC@2 7 -500 -200 200 R 40 40 1 1 U X NR 8 -500 200 200 R 40 40 1 1 P X OUT 6 500 300 200 L 40 40 1 1 I X TRIM 5 -500 300 200 R 40 40 1 1 P X V+ 2 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: REF102P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REF102P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REF102 F0 "IC" -300 425 50 H V L B F1 "REF102P" -300 -400 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 300 -300 P 2 1 0 0 300 -300 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X COM 4 500 -200 200 L 40 40 1 1 W X NC 1 -500 0 200 R 40 40 1 1 U X NC@1 3 -500 -100 200 R 40 40 1 1 U X NC@2 7 -500 -200 200 R 40 40 1 1 U X NR 8 -500 200 200 R 40 40 1 1 P X OUT 6 500 300 200 L 40 40 1 1 I X TRIM 5 -500 300 200 R 40 40 1 1 P X V+ 2 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: REF102U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REF102U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REF102 F0 "IC" -300 425 50 H V L B F1 "REF102U" -300 -400 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 300 -300 P 2 1 0 0 300 -300 300 400 P 2 1 0 0 300 400 -300 400 P 2 1 0 0 -300 400 -300 -300 X COM 4 500 -200 200 L 40 40 1 1 W X NC 1 -500 0 200 R 40 40 1 1 U X NC@1 3 -500 -100 200 R 40 40 1 1 U X NC@2 7 -500 -200 200 R 40 40 1 1 U X NR 8 -500 200 200 R 40 40 1 1 P X OUT 6 500 300 200 L 40 40 1 1 I X TRIM 5 -500 300 200 R 40 40 1 1 P X V+ 2 500 0 200 L 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: REF200P # Package Name: DIL08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REF200P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REF200 F0 "IC" -400 425 50 H V L B F1 "REF200P" -400 -400 50 H V L B F2 "burr-brown-DIL08" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -300 300 -300 P 2 1 0 0 300 -300 300 400 P 2 1 0 0 300 400 -400 400 P 2 1 0 0 -400 400 -400 -300 X I1H 8 -600 100 200 R 40 40 1 1 P X I1L 1 500 100 200 L 40 40 1 1 P X I2H 7 -600 0 200 R 40 40 1 1 P X I2L 2 500 0 200 L 40 40 1 1 P X MCOM 3 500 -200 200 L 40 40 1 1 P X MIN 5 -600 300 200 R 40 40 1 1 I X MOUT 4 500 300 200 L 40 40 1 1 O X SUBST 6 -600 -200 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: REF200U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REF200U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REF200 F0 "IC" -400 425 50 H V L B F1 "REF200U" -400 -400 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 -400 -300 300 -300 P 2 1 0 0 300 -300 300 400 P 2 1 0 0 300 400 -400 400 P 2 1 0 0 -400 400 -400 -300 X I1H 8 -600 100 200 R 40 40 1 1 P X I1L 1 500 100 200 L 40 40 1 1 P X I2H 7 -600 0 200 R 40 40 1 1 P X I2L 2 500 0 200 L 40 40 1 1 P X MCOM 3 500 -200 200 L 40 40 1 1 P X MIN 5 -600 300 200 R 40 40 1 1 I X MOUT 4 500 300 200 L 40 40 1 1 O X SUBST 6 -600 -200 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: REF1004U # Package Name: SO08 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REF1004U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REF1004 F0 "IC" -300 325 50 H V L B F1 "REF1004U" -300 -400 50 H V L B F2 "burr-brown-SO08" 0 150 50 H I C C DRAW P 2 1 0 0 300 -300 -300 -300 P 2 1 0 0 -300 -300 -300 300 P 2 1 0 0 -300 300 300 300 P 2 1 0 0 300 300 300 -300 X A 4 -500 200 200 R 40 40 1 1 P X C 6 -500 100 200 R 40 40 1 1 P X C1 8 -500 0 200 R 40 40 1 1 P X NC 1 500 200 200 L 40 40 1 1 U X NC@1 2 500 100 200 L 40 40 1 1 U X NC@2 3 500 0 200 L 40 40 1 1 U X NC@3 5 500 -100 200 L 40 40 1 1 U X NC@4 7 500 -200 200 L 40 40 1 1 U ENDDRAW ENDDEF # # Dev Name: REG1117 # Package Name: SOT223 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REG1117 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REG1118 F0 "IC" -300 225 50 H V L B F1 "REG1117" -200 100 50 H V L B F2 "burr-brown-SOT223" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 300 -300 P 2 1 0 0 300 -300 300 200 P 2 1 0 0 300 200 -300 200 P 2 1 0 0 -300 200 -300 -300 X GND 1 0 -500 200 U 40 40 1 1 W X VIN 3 -500 0 200 R 40 40 1 1 I X VOUT 2 500 0 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: REG1117F # Package Name: DD-3 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REG1117F IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REG1118 F0 "IC" -300 225 50 H V L B F1 "REG1117F" -200 100 50 H V L B F2 "burr-brown-DD-3" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 300 -300 P 2 1 0 0 300 -300 300 200 P 2 1 0 0 300 200 -300 200 P 2 1 0 0 -300 200 -300 -300 X GND 1 0 -500 200 U 40 40 1 1 W X VIN 3 -500 0 200 R 40 40 1 1 I X VOUT 2 500 0 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: REG1118 # Package Name: SOT223 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF REG1118 IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: REG1118 F0 "IC" -300 225 50 H V L B F1 "REG1118" -200 100 50 H V L B F2 "burr-brown-SOT223" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -300 300 -300 P 2 1 0 0 300 -300 300 200 P 2 1 0 0 300 200 -300 200 P 2 1 0 0 -300 200 -300 -300 X GND 2 0 -500 200 U 40 40 1 1 W X VIN 3 -500 0 200 R 40 40 1 1 I X VOUT 1 500 0 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: XTR101A # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR101A IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR101A F0 "IC" 400 350 50 H V L B F1 "XTR101A" 400 500 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -600 -900 900 0 P 2 1 0 0 900 0 -600 900 P 2 1 0 0 -600 900 -600 -900 P 2 1 0 0 -400 800 -400 775 P 2 1 0 0 -200 700 -200 650 P 2 1 0 0 -200 -700 -200 -675 P 2 1 0 0 0 -600 0 -550 P 2 1 0 0 200 -500 200 -425 P 2 1 0 0 200 500 200 425 X +IN 4 -700 -300 100 R 40 40 1 1 I X -IN 3 -700 300 100 R 40 40 1 1 I X B 12 1000 0 100 L 40 40 1 1 O X BW 13 400 -500 200 U 40 40 1 1 O X E 9 600 -400 200 U 40 40 1 1 O X IREF1 10 -400 1000 200 D 40 40 1 1 I X IREF2 11 -200 900 200 D 40 40 1 1 I X OUT 7 200 -700 200 U 40 40 1 1 O X SPAN_0 5 -700 100 100 R 40 40 1 1 P X SPAN_1 6 -700 -100 100 R 40 40 1 1 P X VCC 8 200 700 200 D 40 40 1 1 W X ZADJ 14 0 -800 200 U 40 40 1 1 O X ZA_0 1 -400 -1000 200 U 40 40 1 1 P X ZA_1 2 -200 -900 200 U 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: XTR101P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR101P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR101 F0 "IC" -300 525 50 H V L B F1 "XTR101P" -300 -600 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -500 400 -500 P 2 1 0 0 400 -500 400 500 P 2 1 0 0 400 500 -300 500 P 2 1 0 0 -300 500 -300 -500 X +IN 4 -500 400 200 R 40 40 1 1 I X -IN 3 -500 300 200 R 40 40 1 1 I X BCONT 12 600 0 200 L 40 40 1 1 O X BW 13 600 -200 200 L 40 40 1 1 P X E 9 600 -100 200 L 40 40 1 1 P X OUT 7 600 400 200 L 40 40 1 1 O X REF1 10 600 200 200 L 40 40 1 1 O X REF2 11 600 100 200 L 40 40 1 1 O X SPAN 5 -500 -300 200 R 40 40 1 1 W X SPAN@1 6 -500 -400 200 R 40 40 1 1 W X VCC 8 600 -400 200 L 40 40 1 1 W X ZA 1 -500 0 200 R 40 40 1 1 P X ZA@1 2 -500 -100 200 R 40 40 1 1 P X ZA@2 14 -500 -200 200 R 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: XTR101U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR101U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR101U F0 "IC" -300 525 50 H V L B F1 "XTR101U" -300 -800 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -700 400 -700 P 2 1 0 0 400 -700 400 500 P 2 1 0 0 400 500 -300 500 P 2 1 0 0 -300 500 -300 -700 X +IN 4 -500 400 200 R 40 40 1 1 I X -IN 3 -500 300 200 R 40 40 1 1 I X BCONT 14 600 0 200 L 40 40 1 1 O X BW 15 600 -200 200 L 40 40 1 1 P X E 11 600 -100 200 L 40 40 1 1 P X NC 8 -500 -500 200 R 40 40 1 1 U X NC@1 9 -500 -600 200 R 40 40 1 1 U X OUT 7 600 400 200 L 40 40 1 1 O X REF1 12 600 200 200 L 40 40 1 1 O X REF2 13 600 100 200 L 40 40 1 1 O X SPAN 5 -500 -200 200 R 40 40 1 1 W X SPAN@1 6 -500 -300 200 R 40 40 1 1 W X VCC 10 600 -600 200 L 40 40 1 1 W X ZA 1 -500 100 200 R 40 40 1 1 P X ZA@1 2 -500 0 200 R 40 40 1 1 P X ZA@2 16 -500 -100 200 R 40 40 1 1 W ENDDRAW ENDDEF # # Dev Name: XTR103P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR103P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR103 F0 "IC" -300 625 50 H V L B F1 "XTR103P" -300 -600 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -500 300 -500 P 2 1 0 0 300 -500 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -500 X +IN 4 -500 500 200 R 40 40 1 1 I X -IN 3 -500 400 200 R 40 40 1 1 I X B 15 500 300 200 L 40 40 1 1 O X E 11 500 200 200 L 40 40 1 1 O X EINT 14 500 100 200 L 40 40 1 1 P X IR1 12 500 -100 200 L 40 40 1 1 P X IR2 13 500 -200 200 L 40 40 1 1 P X OUT 7 500 500 200 L 40 40 1 1 O X RG 5 -500 200 200 R 40 40 1 1 P X RG@1 6 -500 100 200 R 40 40 1 1 P X RLIN 8 -500 -300 200 R 40 40 1 1 P X RLIN@1 9 -500 -400 200 R 40 40 1 1 P X V+ 10 500 -400 200 L 40 40 1 1 W X ZA 1 -500 0 200 R 40 40 1 1 P X ZA@1 2 -500 -100 200 R 40 40 1 1 P X ZA@2 16 -500 -200 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: XTR103U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR103U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR103 F0 "IC" -300 625 50 H V L B F1 "XTR103U" -300 -600 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -500 300 -500 P 2 1 0 0 300 -500 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -500 X +IN 4 -500 500 200 R 40 40 1 1 I X -IN 3 -500 400 200 R 40 40 1 1 I X B 15 500 300 200 L 40 40 1 1 O X E 11 500 200 200 L 40 40 1 1 O X EINT 14 500 100 200 L 40 40 1 1 P X IR1 12 500 -100 200 L 40 40 1 1 P X IR2 13 500 -200 200 L 40 40 1 1 P X OUT 7 500 500 200 L 40 40 1 1 O X RG 5 -500 200 200 R 40 40 1 1 P X RG@1 6 -500 100 200 R 40 40 1 1 P X RLIN 8 -500 -300 200 R 40 40 1 1 P X RLIN@1 9 -500 -400 200 R 40 40 1 1 P X V+ 10 500 -400 200 L 40 40 1 1 W X ZA 1 -500 0 200 R 40 40 1 1 P X ZA@1 2 -500 -100 200 R 40 40 1 1 P X ZA@2 16 -500 -200 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: XTR104P # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR104P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR104 F0 "IC" -300 625 50 H V L B F1 "XTR104P" -300 -600 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -500 300 -500 P 2 1 0 0 300 -500 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -500 X +IN 1 -500 500 200 R 40 40 1 1 I X +LIN 3 -500 300 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X -LIN 4 -500 200 200 R 40 40 1 1 I X B 13 500 300 200 L 40 40 1 1 O X E 11 500 200 200 L 40 40 1 1 O X OUT 7 500 500 200 L 40 40 1 1 O X RG 5 -500 0 200 R 40 40 1 1 P X RG@1 6 -500 -100 200 R 40 40 1 1 P X RLIN 8 500 -100 200 L 40 40 1 1 P X RLIN@1 9 500 -200 200 L 40 40 1 1 P X V+ 10 500 -400 200 L 40 40 1 1 W X VREF 12 500 100 200 L 40 40 1 1 O X ZA 14 -500 -200 200 R 40 40 1 1 P X ZA@1 15 -500 -300 200 R 40 40 1 1 P X ZA@2 16 -500 -400 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: XTR104U # Package Name: SO16-1 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR104U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR104 F0 "IC" -300 625 50 H V L B F1 "XTR104U" -300 -600 50 H V L B F2 "burr-brown-SO16-1" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -500 300 -500 P 2 1 0 0 300 -500 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -500 X +IN 1 -500 500 200 R 40 40 1 1 I X +LIN 3 -500 300 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X -LIN 4 -500 200 200 R 40 40 1 1 I X B 13 500 300 200 L 40 40 1 1 O X E 11 500 200 200 L 40 40 1 1 O X OUT 7 500 500 200 L 40 40 1 1 O X RG 5 -500 0 200 R 40 40 1 1 P X RG@1 6 -500 -100 200 R 40 40 1 1 P X RLIN 8 500 -100 200 L 40 40 1 1 P X RLIN@1 9 500 -200 200 L 40 40 1 1 P X V+ 10 500 -400 200 L 40 40 1 1 W X VREF 12 500 100 200 L 40 40 1 1 O X ZA 14 -500 -200 200 R 40 40 1 1 P X ZA@1 15 -500 -300 200 R 40 40 1 1 P X ZA@2 16 -500 -400 200 R 40 40 1 1 P ENDDRAW ENDDEF # # Dev Name: XTR105P # Package Name: DIL14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR105P IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR105 F0 "IC" -300 625 50 H V L B F1 "XTR105P" -300 -500 50 H V L B F2 "burr-brown-DIL14" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -400 X +IN 13 -500 500 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X B 9 500 300 200 L 40 40 1 1 O X E 8 500 200 200 L 40 40 1 1 O X IR1 1 500 0 200 L 40 40 1 1 P X IR2 14 500 -100 200 L 40 40 1 1 P X IRET 6 -500 300 200 R 40 40 1 1 I X NC 5 -500 -300 200 R 40 40 1 1 U X OUT 7 500 500 200 L 40 40 1 1 O X RG 3 -500 0 200 R 40 40 1 1 P X RG@1 4 -500 -100 200 R 40 40 1 1 P X V+ 10 500 -300 200 L 40 40 1 1 W X VLIN 12 -500 100 200 R 40 40 1 1 P X VREG 11 500 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: XTR105U # Package Name: SO14 # Dev Tech: '' # Dev Prefix: IC # Gate count = 1 # DEF XTR105U IC 0 40 Y Y 1 L N # Gate Name: G$1 # Symbol Name: XTR105 F0 "IC" -300 625 50 H V L B F1 "XTR105U" -300 -500 50 H V L B F2 "burr-brown-SO14" 0 150 50 H I C C DRAW P 2 1 0 0 -300 -400 300 -400 P 2 1 0 0 300 -400 300 600 P 2 1 0 0 300 600 -300 600 P 2 1 0 0 -300 600 -300 -400 X +IN 13 -500 500 200 R 40 40 1 1 I X -IN 2 -500 400 200 R 40 40 1 1 I X B 9 500 300 200 L 40 40 1 1 O X E 8 500 200 200 L 40 40 1 1 O X IR1 1 500 0 200 L 40 40 1 1 P X IR2 14 500 -100 200 L 40 40 1 1 P X IRET 6 -500 300 200 R 40 40 1 1 I X NC 5 -500 -300 200 R 40 40 1 1 U X OUT 7 500 500 200 L 40 40 1 1 O X RG 3 -500 0 200 R 40 40 1 1 P X RG@1 4 -500 -100 200 R 40 40 1 1 P X V+ 10 500 -300 200 L 40 40 1 1 W X VLIN 12 -500 100 200 R 40 40 1 1 P X VREG 11 500 400 200 L 40 40 1 1 O ENDDRAW ENDDEF # # Dev Name: XTR110A # Package Name: DIL16 # Dev Tech: '' # Dev Prefix: IC # Gate count = 2 # DEF XTR110A IC 0 40 Y Y 2 L N # Gate Name: G$1 # Symbol Name: XTR110A F0 "IC" -500 650 50 H V L B F1 "XTR110A" -500 -700 50 H V L B F2 "burr-brown-DIL16" 0 150 50 H I C C DRAW P 2 1 0 0 -500 600 -500 -600 P 2 1 0 0 -500 -600 600 -600 P 2 1 0 0 600 -600 600 600 P 2 1 0 0 600 600 -500 600 X 4MASPAN 10 700 -400 100 L 40 40 1 1 P X 16MASPAN 9 700 -500 100 L 40 40 1 1 P X GATE 14 700 200 100 L 40 40 1 1 P X OFFSET1 7 700 0 100 L 40 40 1 1 P X OFFSET2 6 700 -100 100 L 40 40 1 1 P X SPAN 8 700 -300 100 L 40 40 1 1 P X SRES 1 700 500 100 L 40 40 1 1 P X SSENSE 13 700 400 100 L 40 40 1 1 P X VIN(5V) 5 -600 -500 100 R 40 40 1 1 P X VIN(10) 4 -600 100 100 R 40 40 1 1 P X VREF_IN 3 -600 -200 100 R 40 40 1 1 P X V_ADJUST 11 -600 300 100 R 40 40 1 1 P X V_FORCE 15 -600 500 100 R 40 40 1 1 P X V_SENSE 12 -600 400 100 R 40 40 1 1 P # Gate Name: P # Symbol Name: PWRN T 1 50 -155 50 0 2 0 GND T 1 50 175 50 0 2 0 VCC X GND 2 0 -300 200 U 40 40 2 1 W X VCC 16 0 300 200 D 40 40 2 1 W ENDDRAW ENDDEF #End Library